메뉴 건너뛰기




Volumn 26, Issue 2, 1997, Pages 396-399

Control of centrifugal blood pump based on the motor current

Author keywords

Automatic RPM control; FFT method; implantable centrifugal pump; Motor current; Suction effect

Indexed keywords

ARTICLE; ASSISTED CIRCULATION; BLOOD PUMP; DEVICE; POWER SPECTRUM;

EID: 0030943363     PISSN: 03000818     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (8)
  • 1
    • 17444439760 scopus 로고
    • Innovative Ventricular assist system
    • Watson JT; Innovative Ventricular assist system : ASAIO J 40 (3) : M902,1994
    • (1994) ASAIO J , vol.40 , Issue.3
    • Watson, J.T.1
  • 2
    • 0029142494 scopus 로고
    • Recent studies of the centrifugal blood pump with a magnetically suspended impeller
    • Akamatsu T, Tsukiya T, Nishimura K, Park C-H, Nakazeki T; Recent studies of the centrifugal blood pump with a magnetically suspended impeller : Artificial Organs 19 (7) : 631-634,1995
    • (1995) Artificial Organs , vol.19 , Issue.7 , pp. 631-634
    • Akamatsu, T.1    Tsukiya, T.2    Nishimura, K.3    Park, C.-H.4    Nakazeki, T.5
  • 3
    • 0029159808 scopus 로고
    • Design of a centrifugal blood pump with magnetic suspension
    • Yamane T, Ikeda T, Orita T, Tsutsui T and Jikuya T; Design of a centrifugal blood pump with magnetic suspension : Artificial Organs 19 (7) : 625-630,1995
    • (1995) Artificial Organs , vol.19 , Issue.7 , pp. 625-630
    • Yamane, T.1    Ikeda, T.2    Orita, T.3    Tsutsui, T.4    Jikuya, T.5
  • 4
    • 0029161604 scopus 로고
    • In vitro analysis of the floating mode phenomenon in the free impeller Gyro Pump
    • Ohara Y, Takatani S and Nose Y; In vitro analysis of the floating mode phenomenon in the free impeller Gyro Pump; Artificial Organs 19 (7) : 635-638,1995
    • (1995) Artificial Organs , vol.19 , Issue.7 , pp. 635-638
    • Ohara, Y.1    Takatani, S.2    Nose, Y.3
  • 6
    • 0029088949 scopus 로고
    • An artificial neural network-based noninvasive detector for suction and left atrium pressure in control of rotary blood pump
    • Christian Stocklmayer, Georg Dorffner Christian Schmidt, Heinrich Schima; An artificial neural network-based noninvasive detector for suction and left atrium pressure in control of rotary blood pump : Artificial Organs 17 (7) : 719-724,1995
    • (1995) Artificial Organs , vol.17 , Issue.7 , pp. 719-724
    • Stocklmayer, C.1    Dorffner, G.2    Schmidt, C.3    Schima, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.