메뉴 건너뛰기




Volumn 48, Issue 1, 1997, Pages 97-109

A method for measurements of hydraulic conductivity of biological membranes in vitro

Author keywords

biomembranes; hydraulic permeability; water

Indexed keywords

HYPERTONIC SOLUTION; MERCURIC CHLORIDE; RINGER SOLUTION;

EID: 0030942336     PISSN: 08675910     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (14)
  • 1
    • 0344341996 scopus 로고
    • EDEMA. Staub NC & Taylor AE (eds), Raven Press, New York
    • Katz MA, Bresler EH. Osmosis. In: EDEMA. Staub NC & Taylor AE (eds), Raven Press, New York - 1984, pp. 39-60.
    • (1984) Osmosis , pp. 39-60
    • Katz, M.A.1    Bresler, E.H.2
  • 4
    • 0029161438 scopus 로고
    • The aquaporin family of water channels in kidney
    • Nielsen S, Agre P. The aquaporin family of water channels in kidney. Kidney Internat 1995; 48: 1057-1068.
    • (1995) Kidney Internat , vol.48 , pp. 1057-1068
    • Nielsen, S.1    Agre, P.2
  • 5
    • 0029135101 scopus 로고
    • Structure and function of kidney water channels
    • Verkman AS, Shi L-B, Frigeri A et al. Structure and function of kidney water channels. Kidney Internat 1995; 48: 1069-1081.
    • (1995) Kidney Internat , vol.48 , pp. 1069-1081
    • Verkman, A.S.1    Shi, L.-B.2    Frigeri, A.3
  • 7
    • 0018731055 scopus 로고
    • Preparation of parietal peritoneum for measurements of in vitro permeability
    • Knapowski JB, Simon MP, Feder EM. Preparation of parietal peritoneum for measurements of in vitro permeability. J Artif Organs 1979; 3: 219-223.
    • (1979) J Artif Organs , vol.3 , pp. 219-223
    • Knapowski, J.B.1    Simon, M.P.2    Feder, E.M.3
  • 8
    • 0021801550 scopus 로고
    • Monolayer mesothelium from the ileal rabbit's mesentery: An experimental model for study of peritoneal kinetics in vitro
    • Brȩborowicz A, Janecki A, Brȩborowicz G, Knapowski J. Monolayer mesothelium from the ileal rabbit's mesentery: an experimental model for study of peritoneal kinetics in vitro. Perit Dial Bull 1985; 5: 96-100.
    • (1985) Perit Dial Bull , vol.5 , pp. 96-100
    • Brȩborowicz, A.1    Janecki, A.2    Brȩborowicz, G.3    Knapowski, J.4
  • 9
    • 0028945046 scopus 로고
    • Does impaired transcellular water transport contribute to net ultrafiltration failure during CAPD?
    • Monquil MCJ, Imholz ALT, Struijk DG, Krediet RT. Does impaired transcellular water transport contribute to net ultrafiltration failure during CAPD? Perit Dial Internal 1995; 15: 42-48.
    • (1995) Perit Dial Internal , vol.15 , pp. 42-48
    • Monquil, M.C.J.1    Imholz, A.L.T.2    Struijk, D.G.3    Krediet, R.T.4
  • 10
  • 11
    • 0025346031 scopus 로고
    • Hydraulically-induced convective solute transport across the rabbit peritoneum
    • Bell JL, Leypold JK, Henderson LW. Hydraulically-induced convective solute transport across the rabbit peritoneum. Kidney Internat 1990; 38: 19-27.
    • (1990) Kidney Internat , vol.38 , pp. 19-27
    • Bell, J.L.1    Leypold, J.K.2    Henderson, L.W.3
  • 12
    • 0000276948 scopus 로고
    • Ultrafiltration with peritoneal dialysis
    • K. Nolph (ed.), Kluver Academic Publ, Dordrecht - Boston - London
    • Henderson LW, Leypold J. Ultrafiltration with peritoneal dialysis. In: Peritoneal Dialysis. K. Nolph (ed.), Kluver Academic Publ, Dordrecht - Boston - London, 1989, pp. 117-132.
    • (1989) Peritoneal Dialysis , pp. 117-132
    • Henderson, L.W.1    Leypold, J.2
  • 13
    • 0021128721 scopus 로고
    • Hypertonicity changes the permeability of the mesothelium
    • Brȩborowicz A, Knapowski J. Hypertonicity changes the permeability of the mesothelium. Perit Dial Bull 1984; 4: 167-169.
    • (1984) Perit Dial Bull , vol.4 , pp. 167-169
    • Brȩborowicz, A.1    Knapowski, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.