Volumn 70, Issue 1-4, 1997, Pages 437-440

Neutron measurements around a high energy lead ion beam at CERN

Author keywords

[No Author keywords available]

Indexed keywords

CONCRETE; LEAD;

EID: 0030940011     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a031992     Document Type: Conference Paper
Times cited : (3)

References (15)
  • 1
    • 0008241529 scopus 로고    scopus 로고
    • Reference High-Energy Radiation Fields at CERN
    • Rabat, Morocco, 18-22 July 1994. Divisional Report CERN/TIS-RP/94-12/CF (European Laboratory for Particle Physics (CERN), Genève)
    • Aroua, A., Höfert, M., Sannikov, A. V. and Stevenson, G. R. Reference High-Energy Radiation Fields at CERN. Presented at the 6th Int. Symp. on Radiation Physics, Rabat, Morocco, 18-22 July 1994. Divisional Report CERN/TIS-RP/94-12/CF (European Laboratory for Particle Physics (CERN), Genève) (1994).
    • 6th Int. Symp. on Radiation Physics , pp. 1994
    • Aroua, A.1    Höfert, M.2    Sannikov, A.V.3    Stevenson, G.R.4
  • 2
    • 44049113315 scopus 로고
    • Evaluation and Test of the Response Matrix of a Multisphere Neutron Spectrometer in a Wide Energy Range
    • Aroua, A., Grecescu, M., Lerch, P., Prêtre, S., Valley, J.-F. and Vylet, V. Evaluation and Test of the Response Matrix of a Multisphere Neutron Spectrometer in a Wide Energy Range. Nucl. Instrum. Methods A321, 298-316 (1992).
    • (1992) Nucl. Instrum. Methods , vol.A321 , pp. 298-316
    • Aroua, A.1    Grecescu, M.2    Lerch, P.3    Prêtre, S.4    Valley, J.-F.5    Vylet, V.6
  • 5
    • 1542476953 scopus 로고
    • A Geiger-Müller γ-Ray Dosimeter with Low Neutron Sensitivity
    • Wagner, E. B. and Hurst, G. S. A Geiger-Müller γ-Ray Dosimeter with Low Neutron Sensitivity. Health Phys. 5, 20 (1961).
    • (1961) Health Phys. , vol.5 , pp. 20
    • Wagner, E.B.1    Hurst, G.S.2
  • 7
    • 0000532439 scopus 로고
    • An Easy-to-Operate Portable Pulse-Height Analysis System for Area Monitoring with TEPC in Radiation Protection
    • Kunz, A. W., Pihet, P., Arend, E. and Menzel, H. G. An Easy-to-Operate Portable Pulse-Height Analysis System for Area Monitoring with TEPC in Radiation Protection. Nucl. Instrum. Methods A299, 696-701 (1990).
    • (1990) Nucl. Instrum. Methods , vol.A299 , pp. 696-701
    • Kunz, A.W.1    Pihet, P.2    Arend, E.3    Menzel, H.G.4
  • 10
    • 0028969890 scopus 로고
    • Quality Factors, Ambient and Personal Dose Equivalent for Neutrons, Based on the New ICRU Stopping Power Data for Protons and Alpha Particles
    • Siebert, B. R. L. and Schuhmacher, H. Quality Factors, Ambient and Personal Dose Equivalent for Neutrons, Based on the New ICRU Stopping Power Data for Protons and Alpha Particles. Radiat. Prot. Dosim. 58(3), 177-183 (1995).
    • (1995) Radiat. Prot. Dosim. , vol.58 , Issue.3 , pp. 177-183
    • Siebert, B.R.L.1    Schuhmacher, H.2
  • 11
    • 0003653716 scopus 로고    scopus 로고
    • ISO/TC85/SC2/WG2/SG3/WD8529/3, Draft
    • ISO. Reference Neutron Radiation, ISO/TC85/SC2/WG2/SG3/WD8529/3, Draft.
    • Reference Neutron Radiation
  • 15
    • 0029056411 scopus 로고
    • On the Use of Tissue-Equivalent Proportional Counters in High Energy Stray Radiation Fields
    • Aroua, A., Höfert, M. and Sannikov, A. V. On the Use of Tissue-Equivalent Proportional Counters in High Energy Stray Radiation Fields. Radiat. Prot. Dosim. 59(1/4), 49-53 (1995).
    • (1995) Radiat. Prot. Dosim. , vol.59 , Issue.1-4 , pp. 49-53
    • Aroua, A.1    Höfert, M.2    Sannikov, A.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.