Volumn 24, Issue 4, 1997, Pages 527-533

Influence of cavity size on the response of cavity chambers to 25- and 45-MeV neutrons

Author keywords

Bragg Gray; cavity theory; dosimetry; neutron kerma coefficient

Indexed keywords

DOSIMETERS; DOSIMETRY; GASES; NEUTRONS;

EID: 0030934814     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.597935     Document Type: Article
Times cited : (1)

References (33)
  • 1
    • 0004746499 scopus 로고
    • American Association of Physicists in Medicine American Institute of Physics, New York
    • "Protocol for Neutron Beam Dosimetry," American Association of Physicists in Medicine (American Institute of Physics, New York, 1980).
    • (1980) Protocol for Neutron Beam Dosimetry
  • 2
    • 0023202277 scopus 로고
    • What degree of accuracy is required and can be achieved in photon and neutron therapy
    • B. J. Mijnheer, J. J. Blattermann, and A Wambersie, "What degree of accuracy is required and can be achieved in photon and neutron therapy," Radiother. Oncol. 8, 237-252 (1987).
    • (1987) Radiother. Oncol. , vol.8 , pp. 237-252
    • Mijnheer, B.J.1    Blattermann, J.J.2    Wambersie, A.3
  • 3
    • 0019827944 scopus 로고
    • European protocol for neutron dosimetry for external beam therapy
    • J J. Broerse, B. J. Mijnheer, and J. R. Williams, "European protocol for neutron dosimetry for external beam therapy," Br. J. Radiol. 54, 882-898 (1981).
    • (1981) Br. J. Radiol. , vol.54 , pp. 882-898
    • Broerse, J.J.1    Mijnheer, B.J.2    Williams, J.R.3
  • 5
    • 0028868999 scopus 로고
    • Gas-to-wall absorbed dose conversion factors for 25 to 250 MeV neutrons
    • W. D. Newhauser, U. J. Schrewe, and B. Wiegel, "Gas-to-wall absorbed dose conversion factors for 25 to 250 MeV neutrons," Radiat. Prot. Dosim. 6, 281-284 (1995).
    • (1995) Radiat. Prot. Dosim. , vol.6 , pp. 281-284
    • Newhauser, W.D.1    Schrewe, U.J.2    Wiegel, B.3
  • 7
    • 0030642390 scopus 로고    scopus 로고
    • Gas-to-wall absorbed dose conversion factors for 25 MeV to 250 MeV neutrons
    • W. D. Newhauser and U. J. Schrewe, "Gas-to-wall absorbed dose conversion factors for 25 MeV to 250 MeV neutrons," Atom. Data Nucl. Data Tables 65, 37-53 (1997).
    • (1997) Atom. Data Nucl. Data Tables , vol.65 , pp. 37-53
    • Newhauser, W.D.1    Schrewe, U.J.2
  • 8
    • 33744690750 scopus 로고
    • Consequences of the corpuscular hypothesis of the γ and x-rays, and the ranges of β rays
    • W. H. Bragg, "Consequences of the corpuscular hypothesis of the γ and x-rays, and the ranges of β rays," Phil. Mag. 20, 385-416 (1910).
    • (1910) Phil. Mag. , vol.20 , pp. 385-416
    • Bragg, W.H.1
  • 9
    • 0003161647 scopus 로고
    • Absorption of penetrating radiation
    • L. H. Gray, "Absorption of penetrating radiation," Proc. Roy. Soc. London Ser. A 122, 647-668 (1929).
    • (1929) Proc. Roy. Soc. London Ser. A , vol.122 , pp. 647-668
    • Gray, L.H.1
  • 10
    • 0000714578 scopus 로고
    • Ionization method for the absolute measurement of γ-ray energy
    • L. H. Gray, "Ionization method for the absolute measurement of γ-ray energy," Proc Roy. Soc. London Ser. A 156, 578-598 (1936).
    • (1936) Proc Roy. Soc. London Ser. A , vol.156 , pp. 578-598
    • Gray, L.H.1
  • 11
    • 0001841920 scopus 로고
    • Deposition of energy by neutrons in spherical cavities
    • R. S. Caswell, "Deposition of energy by neutrons in spherical cavities," Radiat. Res. 27, 92-107 (1966).
    • (1966) Radiat. Res. , vol.27 , pp. 92-107
    • Caswell, R.S.1
  • 12
    • 33744586486 scopus 로고
    • The derivation of tissue doses from measurements with a tissue equivalent ionisation chamber
    • Conference held at Neuherberg, 23-27 May 1977, edited by G. Burger and H. G. Ebert, Commission of the European Communities, Euratom EUR
    • A. A. Edwards, "The derivation of tissue doses from measurements with a tissue equivalent ionisation chamber," in Proceedings of the 3rd Symposium on Neutron Dosimetry in Biology and Medicine, Conference held at Neuherberg, 23-27 May 1977, edited by G. Burger and H. G. Ebert, Commission of the European Communities, Euratom EUR 5848, 1978, pp. 535-547
    • (1978) Proceedings of the 3rd Symposium on Neutron Dosimetry in Biology and Medicine , vol.5848 , pp. 535-547
    • Edwards, A.A.1
  • 13
    • 0018897055 scopus 로고
    • Comparison of the Bragg-Gray theory corollaries to fast-neutron cavity ionization measurements at 14.8 MeV
    • F. H. Attix, D. W. Pearson, P. M. DeLuca, Jr., and S. J. Goetsch, "Comparison of the Bragg-Gray theory corollaries to fast-neutron cavity ionization measurements at 14.8 MeV," Health Phys. 38, 623-633 (1980).
    • (1980) Health Phys. , vol.38 , pp. 623-633
    • Attix, F.H.1    Pearson, D.W.2    DeLuca Jr., P.M.3    Goetsch, S.J.4
  • 14
    • 0019977073 scopus 로고
    • Neutron dosimetry with spherical ionization chambers III. Calculated results for tissue-equivalent chambers
    • A Rubach and H. Bichsel, "Neutron dosimetry with spherical ionization chambers III. Calculated results for tissue-equivalent chambers," Phys. Med. Biol. 27, 1231-1243 (1982).
    • (1982) Phys. Med. Biol. , vol.27 , pp. 1231-1243
    • Rubach, A.1    Bichsel, H.2
  • 15
  • 16
    • 0020517094 scopus 로고
    • Neutron dosimetry with spherical ionization chambers V. Experimental measurements and comparison of calculations of the cavity size dependence of the specific ionization
    • A. Rubach, H. Bichsel, and A. Ito, "Neutron dosimetry with spherical ionization chambers V. Experimental measurements and comparison of calculations of the cavity size dependence of the specific ionization," Phys. Med. Biol. 28, 913-924 (1983).
    • (1983) Phys. Med. Biol. , vol.28 , pp. 913-924
    • Rubach, A.1    Bichsel, H.2    Ito, A.3
  • 17
    • 18344400359 scopus 로고
    • Theoretical characteristics of a graphite ionization chamber filled with carbon dioxide
    • M Makarewicz and S. Pszona, "Theoretical characteristics of a graphite ionization chamber filled with carbon dioxide," Nucl. Instrum. Methods 153, 423-428 (1978).
    • (1978) Nucl. Instrum. Methods , vol.153 , pp. 423-428
    • Makarewicz, M.1    Pszona, S.2
  • 18
    • 0019947253 scopus 로고
    • Effect of cavity size on the sensitivity of a TE-walled, TE-gas-filled ionization chamber for fast neutrons
    • S. Pszona and M. Makarewicz, "Effect of cavity size on the sensitivity of a TE-walled, TE-gas-filled ionization chamber for fast neutrons," Phys Med. Biol. 27, 1015-1022 (1982).
    • (1982) Phys Med. Biol. , vol.27 , pp. 1015-1022
    • Pszona, S.1    Makarewicz, M.2
  • 19
    • 0022607635 scopus 로고
    • Neutron kerma factors for magnesium and aluminum measured with low-pressure proportional counters
    • G. Bühler, H. Menzel, H. Schuhmacher, G. Dietze, and S. Guldbakke, "Neutron kerma factors for magnesium and aluminum measured with low-pressure proportional counters," Phys. Med. Biol. 31, 601-612 (1986).
    • (1986) Phys. Med. Biol. , vol.31 , pp. 601-612
    • Bühler, G.1    Menzel, H.2    Schuhmacher, H.3    Dietze, G.4    Guldbakke, S.5
  • 20
    • 0021684547 scopus 로고
    • n values for infinitesimal and infinite tissue-equivalent ion chambers in monoenergetic neutron fields from thermal to 20 MeV
    • n values for infinitesimal and infinite tissue-equivalent ion chambers in monoenergetic neutron fields from thermal to 20 MeV," Radiat. Prot. Dosim 9, 215-218 (1984).
    • (1984) Radiat. Prot. Dosim , vol.9 , pp. 215-218
    • Siebert, B.R.L.1    Coyne, J.J.2
  • 25
    • 0000792876 scopus 로고
    • Note on the Bragg-Gray cavity principle for measuring energy dissipation
    • U. Fano, "Note on the Bragg-Gray cavity principle for measuring energy dissipation," Radiat. Res. 1, 237-240 (1954).
    • (1954) Radiat. Res. , vol.1 , pp. 237-240
    • Fano, U.1
  • 26
    • 0026795240 scopus 로고
    • Measurement of kerma factors for carbon and A-150 plastic: Neutron energies from 13.9 to 20 MeV
    • P. Pihet, S. Guldbakke, H. G. Menzel, and H. Schuhmacher, "Measurement of kerma factors for carbon and A-150 plastic: Neutron energies from 13.9 to 20 MeV," Phys. Med. Biol 37, 1957-1976 (1992).
    • (1992) Phys. Med. Biol , vol.37 , pp. 1957-1976
    • Pihet, P.1    Guldbakke, S.2    Menzel, H.G.3    Schuhmacher, H.4
  • 27
    • 0026693437 scopus 로고
    • Measurement of kerma factors for carbon and A-150 plastic at neutron energies of 26.3 MeV to 38.7 MeV
    • H. Schuhmacher, H. J. Brede, R. Henneck, A. Kunz, J. P. Meulders, P. Pihet, and U. J. Schrewe, "Measurement of kerma factors for carbon and A-150 plastic at neutron energies of 26.3 MeV to 38.7 MeV," Phys. Med. Biol. 37, 1265-1281 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1265-1281
    • Schuhmacher, H.1    Brede, H.J.2    Henneck, R.3    Kunz, A.4    Meulders, J.P.5    Pihet, P.6    Schrewe, U.J.7
  • 29
    • 85027218337 scopus 로고
    • W. D Newhauser, "Neutron kerma factor measurements in the 25-MeV to 85-MeV neutron energy range," Ph.D. dissertation at the University of Wisconsin (Medical Physics Publishing, Madison, WI, 1995); abstract in Med. Phys 22, 2128 (1995).
    • (1995) Med. Phys , vol.22 , pp. 2128
  • 31
    • 0018933433 scopus 로고
    • Kerma factors for neutron energies below 30 MeV
    • R. S. Caswell, J. J. Coyne, and M. L. Randolph, "Kerma factors for neutron energies below 30 MeV," Radiat. Res. 83, 217-254 (1980).
    • (1980) Radiat. Res. , vol.83 , pp. 217-254
    • Caswell, R.S.1    Coyne, J.J.2    Randolph, M.L.3