메뉴 건너뛰기




Volumn 22, Issue 4, 1997, Pages 217-221

Preliminary experience with double-phase SPECT using Tc-99m sestamibi in patients with hyperparathyroidism

Author keywords

[No Author keywords available]

Indexed keywords

METHOXY ISOBUTYL ISONITRILE TECHNETIUM TC 99M;

EID: 0030934382     PISSN: 03639762     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003072-199704000-00001     Document Type: Article
Times cited : (20)

References (21)
  • 1
    • 0018918911 scopus 로고
    • Primary hyperparathyroidism: Incidence, morbidity and potential impact in a community
    • Heath H, Hodgson SF, Kennedy MA: Primary hyperparathyroidism: incidence, morbidity and potential impact in a community, N Engl J Med 302:189, 1980.
    • (1980) N Engl J Med , vol.302 , pp. 189
    • Heath, H.1    Hodgson, S.F.2    Kennedy, M.A.3
  • 2
    • 0016784361 scopus 로고
    • Success rate of cervical exploration for hyperparathyroidism
    • Satava RM, Beahrs OH, Scholz DA: Success rate of cervical exploration for hyperparathyroidism. Arch Surg 110:625, 1975.
    • (1975) Arch Surg , vol.110 , pp. 625
    • Satava, R.M.1    Beahrs, O.H.2    Scholz, D.A.3
  • 3
    • 0027393964 scopus 로고
    • Cervical exploration for primary hperparathyroidisrn
    • Shaha AR, Jaffe BM: Cervical exploration for primary hperparathyroidisrn. J Surg Oncol 52:14, 1993.
    • (1993) J Surg Oncol , vol.52 , pp. 14
    • Shaha, A.R.1    Jaffe, B.M.2
  • 4
    • 0015632150 scopus 로고
    • Parathyroid localization by angiographic techniques in patients with previous neck surgery
    • Doppman JL, Wells SA, Shimkin PM, et al: Parathyroid localization by angiographic techniques in patients with previous neck surgery. Br J Radiol 46:403, 1973.
    • (1973) Br J Radiol , vol.46 , pp. 403
    • Doppman, J.L.1    Wells, S.A.2    Shimkin, P.M.3
  • 5
    • 0021018048 scopus 로고
    • Rapid localization of parathyroid tumors by selective venous catheterization and parathyroid hormone assay
    • Hsu FSK, Clark OH, Serala TY, et al: Rapid localization of parathyroid tumors by selective venous catheterization and parathyroid hormone assay. Surgery 94:873, 1983.
    • (1983) Surgery , vol.94 , pp. 873
    • Hsu, F.S.F.1    Clark, O.H.2    Serala, T.Y.3
  • 6
    • 0023515123 scopus 로고
    • Advances in localizing studies (MRI, ultrasound, CT and thallium-technetium scanning) in patients with persistent or recurrent hyperparathyroidism
    • Levin KE, Gooding GAW, Okerlund MD, et al: Advances in localizing studies (MRI, ultrasound, CT and thallium-technetium scanning) in patients with persistent or recurrent hyperparathyroidism. Surgery 102:917, 1987.
    • (1987) Surgery , vol.102 , pp. 917
    • Levin, K.E.1    Gooding, G.A.W.2    Okerlund, M.D.3
  • 7
    • 0023895942 scopus 로고
    • Diagnosis of recurrent hyperparathyroidism: Comparison of MR imaging and other imaging techniques
    • Aufferman W, Gooding GAW, Okerlund MD, et al: Diagnosis of recurrent hyperparathyroidism: comparison of MR imaging and other imaging techniques. Am J Radiol 150:1027, 1988.
    • (1988) Am J Radiol , vol.150 , pp. 1027
    • Aufferman, W.1    Gooding, G.A.W.2    Okerlund, M.D.3
  • 8
    • 0020574162 scopus 로고
    • Location of parathyroid adenomas by thallium-201 and technetium-99m subtraction scanning
    • Young AE, Gaunt JI, Croft DN, et al: Location of parathyroid adenomas by thallium-201 and technetium-99m subtraction scanning. Br Med J 286:1384, 1983.
    • (1983) Br Med J , vol.286 , pp. 1384
    • Young, A.E.1    Gaunt, J.I.2    Croft, D.N.3
  • 9
    • 0024854487 scopus 로고
    • Tc-99m sestamibi: A new agent for parathyroid imaging
    • Coakley AJ, Kettle AG, Wells CP, et al: Tc-99m sestamibi: a new agent for parathyroid imaging. Nucl Med Commun 10:791, 1989.
    • (1989) Nucl Med Commun , vol.10 , pp. 791
    • Coakley, A.J.1    Kettle, A.G.2    Wells, C.P.3
  • 10
    • 0026582792 scopus 로고
    • Parathyroid imaging with technetium-99m-sestamibi: Preoperative localization and tissue uptake studies
    • O'Doherty MJ, Kettle AG, Wells P, et al: Parathyroid imaging with technetium-99m-sestamibi: preoperative localization and tissue uptake studies. J Nucl Med 33:313, 1992.
    • (1992) J Nucl Med , vol.33 , pp. 313
    • O'Doherty, M.J.1    Kettle, A.G.2    Wells, P.3
  • 11
    • 0028297991 scopus 로고
    • Preoperative imaging of abnormal parathyroid glands in patients with hyperparathyroid disease using combination Tc-99m-pertechnetate and Tc-99m-sestamibi radionuclide scans
    • Wei JP, Burke GJ, Mansberger AR: Preoperative imaging of abnormal parathyroid glands in patients with hyperparathyroid disease using combination Tc-99m-pertechnetate and Tc-99m-sestamibi radionuclide scans. Ann Surg 219:568, 1994.
    • (1994) Ann Surg , vol.219 , pp. 568
    • Wei, J.P.1    Burke, G.J.2    Mansberger, A.R.3
  • 12
    • 0028157097 scopus 로고
    • Impact of technetium-99m-sestamibi localization on operative time and success of operations for primary hyperparathyroidism
    • Casas AT, Burke GJ, Mansherger AR, et al: Impact of technetium-99m-sestamibi localization on operative time and success of operations for primary hyperparathyroidism. Am Surg 60:12, 1994.
    • (1994) Am Surg , vol.60 , pp. 12
    • Casas, A.T.1    Burke, G.J.2    Mansherger, A.R.3
  • 13
    • 0028833379 scopus 로고
    • Primary hyperparathyroidism: Is technetium-99m-sestamibi/iodine-123 subtraction scanning the best procedure to locate enlarged glands before surgery?
    • Hindie E, Melliere D, Simon D, et al: Primary hyperparathyroidism: is technetium-99m-sestamibi/iodine-123 subtraction scanning the best procedure to locate enlarged glands before surgery? J Clin Endocrinol Metab 80:302, 1995.
    • (1995) J Clin Endocrinol Metab , vol.80 , pp. 302
    • Hindie, E.1    Melliere, D.2    Simon, D.3
  • 14
    • 0026674754 scopus 로고
    • Detection and localization of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double-phase study)
    • Taillefer R, Boucher Y, Potvin C, et al: Detection and localization of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double-phase study). J Nucl Med 33:1801, 1992.
    • (1992) J Nucl Med , vol.33 , pp. 1801
    • Taillefer, R.1    Boucher, Y.2    Potvin, C.3
  • 15
    • 0023039593 scopus 로고
    • Prospective comparison of radionuclide, computed tomographic, and sonographic localization of parathyroid tumors
    • Kruhsack AJ, Wilson SD, Lawson TL, et al: Prospective comparison of radionuclide, computed tomographic, and sonographic localization of parathyroid tumors. World J Surg 10:579, 1986.
    • (1986) World J Surg , vol.10 , pp. 579
    • Kruhsack, A.J.1    Wilson, S.D.2    Lawson, T.L.3
  • 16
    • 0024342354 scopus 로고
    • The reasons for failure in parathyroid operations
    • Levin KE, Clark OH: The reasons for failure in parathyroid operations. Arch Surg 124:911, 1989.
    • (1989) Arch Surg , vol.124 , pp. 911
    • Levin, K.E.1    Clark, O.H.2
  • 17
    • 0026746218 scopus 로고
    • Comparison of imaging methods for localization of parathyroid tumors
    • Kohri K, Ishikawa Y, Kodama M, et al: Comparison of imaging methods for localization of parathyroid tumors. Am J Surg 164:140, 1992.
    • (1992) Am J Surg , vol.164 , pp. 140
    • Kohri, K.1    Ishikawa, Y.2    Kodama, M.3
  • 19
    • 0028131220 scopus 로고
    • Localization procedures in patients with persistent or recurrent hyperparathyroidism
    • Rodriguez JM, Tezelman S, Siperstein AE, et al: Localization procedures in patients with persistent or recurrent hyperparathyroidism. Arch Surg 129:870, 1994.
    • (1994) Arch Surg , vol.129 , pp. 870
    • Rodriguez, J.M.1    Tezelman, S.2    Siperstein, A.E.3
  • 20
    • 0028784320 scopus 로고
    • Technetium-99m-sestamibi imaging before reoperation for primary hyperparathyroidism
    • Chen CC, Skarulis MC, Fraker DL, et al: Technetium-99m-sestamibi imaging before reoperation for primary hyperparathyroidism. J Nucl Med 36:2186, 1995.
    • (1995) J Nucl Med , vol.36 , pp. 2186
    • Chen, C.C.1    Skarulis, M.C.2    Fraker, D.L.3
  • 21
    • 0028867440 scopus 로고
    • Hyperparathyroidism in high-risk surgical patients: Evaluation with double-phase technetium-99m sestamibi imaging
    • Lee VS, Wilkinson RH, Leight GS, et al: Hyperparathyroidism in high-risk surgical patients: evaluation with double-phase technetium-99m sestamibi imaging. Radiology 197:627, 1995.
    • (1995) Radiology , vol.197 , pp. 627
    • Lee, V.S.1    Wilkinson, R.H.2    Leight, G.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.