메뉴 건너뛰기




Volumn 119, Issue 12, 1997, Pages 2853-2860

Photochemistry of Roussin's red salt, Na2[Fe2S2(NO)4], and of Roussin's black salt, NH4[Fe4S3(NO)7]. In situ nitric oxide generation to sensitize γ-radiation induced cell death

Author keywords

[No Author keywords available]

Indexed keywords

IRON SALT; NITRIC OXIDE;

EID: 0030933085     PISSN: 00027863     EISSN: None     Source Type: Journal    
DOI: 10.1021/ja963914n     Document Type: Article
Times cited : (163)

References (51)
  • 24
    • 1842351924 scopus 로고    scopus 로고
    • note
    • + to a solution of the sodium salt in water gives a material with an IR spectrum identical to that published, so the shifts appear to be the result of specific cation interactions with the cluster anion in the solid.
  • 41
    • 1842313473 scopus 로고    scopus 로고
    • 11b commented that RBS solutions underwent thermal degradation under the conditions described here; however, we have found little problem with dark reactions while handling these materials during setup and execution of photochemical experiments
    • 11b commented that RBS solutions underwent thermal degradation under the conditions described here; however, we have found little problem with dark reactions while handling these materials during setup and execution of photochemical experiments.
  • 42
    • 1842350927 scopus 로고    scopus 로고
    • Sadtler Standard Grating Spectra, Sadtler Research Laboratories, Inc., 1974, v. 34: sodium nitrate spectrum, 33687; sodium nitrite spectrum, 33688
    • Sadtler Standard Grating Spectra, Sadtler Research Laboratories, Inc., 1974, v. 34: sodium nitrate spectrum, 33687; sodium nitrite spectrum, 33688.
  • 44
    • 1842311593 scopus 로고    scopus 로고
    • note
    • -, respectively.
  • 47
    • 1842359749 scopus 로고    scopus 로고
    • J. Bourassa, studies in progress
    • J. Bourassa, studies in progress.
  • 49
    • 1842277040 scopus 로고    scopus 로고
    • Another way to evaluate the effectiveness of the sensitizer is to use sensitizer enhancement ratios (SERs). SERs are calculated by dividing the radiation dose for control hypoxic conditions by the radiation dose for various agents or alternative procedures under hypoxic conditions at the 10% surviving fraction level (ref 23). The experiments with 0.75 mM RRS (Figure 6) gave a SER of ∼1.6
    • Another way to evaluate the effectiveness of the sensitizer is to use sensitizer enhancement ratios (SERs). SERs are calculated by dividing the radiation dose for control hypoxic conditions by the radiation dose for various agents or alternative procedures under hypoxic conditions at the 10% surviving fraction level (ref 23). The experiments with 0.75 mM RRS (Figure 6) gave a SER of ∼1.6.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.