메뉴 건너뛰기




Volumn 73, Issue 4, 1997, Pages 690-693

Radiation exposure during cardiology fellowship training

Author keywords

Dose assessment; Exposure; Medical; Occupational; Radiation

Indexed keywords

ARTICLE; CARDIOLOGY; CATHETERIZATION; DOSIMETRY; FLUOROSCOPY; HEALTH HAZARD; OCCUPATIONAL EXPOSURE; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; RADIATION EXPOSURE; RESIDENCY EDUCATION;

EID: 0030931537     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004032-199710000-00016     Document Type: Article
Times cited : (61)

References (11)
  • 1
    • 0018126446 scopus 로고
    • Radiation exposure to the operator performing cardiac angiography with U-arm systems
    • Balter, S.; Sones, F. M., Jr.; Brancato, R. Radiation exposure to the operator performing cardiac angiography with U-arm systems. Circulation 58:925-932; 1978.
    • (1978) Circulation , vol.58 , pp. 925-932
    • Balter, S.1    Sones F.M., Jr.2    Brancato, R.3
  • 2
    • 0026595717 scopus 로고
    • Balloon angioplasty of chronic total coronary artery occlusions: What does it cost in radiation exposure, time, and materials?
    • Bell, M. R.; Berger, P. B.; Menke, K. K.; Holmes, D. R. Balloon angioplasty of chronic total coronary artery occlusions: what does it cost in radiation exposure, time, and materials? Cathet. Cardiovas. Diagn. 25:10-15; 1992.
    • (1992) Cathet. Cardiovas. Diagn. , vol.25 , pp. 10-15
    • Bell, M.R.1    Berger, P.B.2    Menke, K.K.3    Holmes, D.R.4
  • 3
    • 0027483246 scopus 로고
    • Coronary angiography: An analysis of radiographic practice in the UK
    • Coulden, R. A.; Readman, L. P. Coronary angiography: an analysis of radiographic practice in the UK. Br. J. Radiol. 66:327-331; 1993.
    • (1993) Br. J. Radiol. , vol.66 , pp. 327-331
    • Coulden, R.A.1    Readman, L.P.2
  • 4
    • 0023634063 scopus 로고
    • Radiation exposure during diagnostic catheterization and single- And double-vessel percutaneous transluminal coronary angioplasty
    • Finci, L.; Meier, B.; Steffenino, G.; Roy, P.; Rutishauser, W. Radiation exposure during diagnostic catheterization and single- and double-vessel percutaneous transluminal coronary angioplasty. Am. J. Cardiol. 60:1401-1403; 1987.
    • (1987) Am. J. Cardiol. , vol.60 , pp. 1401-1403
    • Finci, L.1    Meier, B.2    Steffenino, G.3    Roy, P.4    Rutishauser, W.5
  • 5
    • 0020378858 scopus 로고
    • Improved radiation protection for physicians performing cardiac catheterization
    • Gertz, E. W.; Wisneski, J. A.; Gould, R. G.; Akin, J. R. Improved radiation protection for physicians performing cardiac catheterization. Am. J. Cardiol. 50:1283-1286; 1992.
    • (1992) Am. J. Cardiol. , vol.50 , pp. 1283-1286
    • Gertz, E.W.1    Wisneski, J.A.2    Gould, R.G.3    Akin, J.R.4
  • 6
    • 0022503744 scopus 로고
    • Video x-ray progressive scanning: New technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization
    • Holmes, D. R., Jr.; Bove, A. A.; Wondrow, M. A.; Gray, J. E. Video x-ray progressive scanning: new technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization. Mayo Clin. Proc. 61:321-326; 1986.
    • (1986) Mayo Clin. Proc. , vol.61 , pp. 321-326
    • Holmes D.R., Jr.1    Bove, A.A.2    Wondrow, M.A.3    Gray, J.E.4
  • 8
    • 0025008635 scopus 로고
    • Effect of pulsed progressive fluoroscopy on reduction of radiation dose in the cardiac catheterization laboratory
    • Holmes, D. R., Jr.; Wondrow, N. M.; Gray, J. E.; Vetter, R. J.; Fellows, J. L.; Julsrud, P. R. Effect of pulsed progressive fluoroscopy on reduction of radiation dose in the cardiac catheterization laboratory. J. Am. Coll. Cardiol. 15:159-162; 1990.
    • (1990) J. Am. Coll. Cardiol. , vol.15 , pp. 159-162
    • Holmes D.R., Jr.1    Wondrow, N.M.2    Gray, J.E.3    Vetter, R.J.4    Fellows, J.L.5    Julsrud, P.R.6
  • 9
    • 0027437745 scopus 로고
    • Radiation risk to patients from percutaneous transluminal coronary angioplasty
    • Pattee, P. L.; Johns, P. C.; Chambers, R. J. Radiation risk to patients from percutaneous transluminal coronary angioplasty. J. Am. Coll. Cardiol. 22:1044-1051; 1993.
    • (1993) J. Am. Coll. Cardiol. , vol.22 , pp. 1044-1051
    • Pattee, P.L.1    Johns, P.C.2    Chambers, R.J.3
  • 10
    • 0026595589 scopus 로고
    • A 5-year follow-up of the radiation exposure to in-room personnel during cardiac catheterization
    • Renuad, L. A 5-year follow-up of the radiation exposure to in-room personnel during cardiac catheterization. Health Phys. 62:10-15; 1992.
    • (1992) Health Phys. , vol.62 , pp. 10-15
    • Renuad, L.1
  • 11
    • 0023871899 scopus 로고
    • Technical consideration for a new x-ray video progressive scanning system for cardiac catheterization
    • Wondrow, M. A.; Bove, A. A.; Holmes, D. R., Jr.; Gray, J. E.; Juisrud, P. R. Technical consideration for a new x-ray video progressive scanning system for cardiac catheterization. Cathet. Cardiovasc. Diagn. 14:126-134; 1988.
    • (1988) Cathet. Cardiovasc. Diagn. , vol.14 , pp. 126-134
    • Wondrow, M.A.1    Bove, A.A.2    Holmes D.R., Jr.3    Gray, J.E.4    Juisrud, P.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.