Evaluation of the IL-682 co-oximeter; Comparison to the il-482 co-oximeter and gas chromatography

Author keywords

[No Author keywords available]

Indexed keywords

CARBOXYHEMOGLOBIN;

EID: 0030930475     PISSN: 00085030     EISSN: None     Source Type: Journal    
DOI: 10.1080/00085030.1997.10757089     Document Type: Article
Times cited : (6)

References (8)
  • 1
    • 0023034135 scopus 로고
    • Carbon monoxide analysis; a comparison of two COOximeters and headspace gas chromatography
    • Costantino A.G., Park J. and Caplan Y.H. Carbon monoxide analysis; a comparison of two COOximeters and headspace gas chromatography. J. Anal. Toxicol. 1986; 10: 190-193.
    • (1986) J. Anal. Toxicol , vol.10 , pp. 190-193
    • Costantino, A.G.1    Park, J.2    Caplan, Y.H.3
  • 2
    • 0023531097 scopus 로고
    • Evaluation of the 1L 482 CO-Oximeter
    • Sedar F.A. and Holleman C.M. Evaluation of the 1L 482 CO-Oximeter. Clin. Chem. 1987; 33(10); 1942-1943.
    • (1987) Clin. Chem , vol.33 , Issue.10 , pp. 1942-1943
    • Sedar, F.A.1    Holleman, C.M.2
  • 3
    • 0024230372 scopus 로고
    • Carboxyhemoglobin as measured by gas chromatography and with the IL 282 and 482 CO-Oximeters. Clin
    • Vreman H.J., Mahoney J.J., Van Kessel A.L. and Stevenson D.K. Carboxyhemoglobin as measured by gas chromatography and with the IL 282 and 482 CO-Oximeters. Clin. Chem. 1988; 34(12): 2562-2566.
    • (1988) Chem , vol.34 , Issue.12 , pp. 2562-2566
    • Vreman, H.J.1    Mahoney, J.J.2    Van Kessel, A.L.3    Stevenson, D.K.4
  • 4
    • 0027255047 scopus 로고
    • Measurement of carboxyhemoglobin and total hemoglobin by five specialized spetrophotometers (CO-Oximeters) in comparison with reference methods
    • Mahoney J.J., Vreman H.J., Stevenson D.K. and Van Kessel A.L. Measurement of carboxyhemoglobin and total hemoglobin by five specialized spetrophotometers (CO-Oximeters) in comparison with reference methods. Clin. Chem. 1993; 39(8): 1693-1700.
    • (1993) Clin. Chem. , vol.39 , Issue.8 , pp. 1693-1700
    • Mahoney, J.J.1    Vreman, H.J.2    Stevenson, D.K.3    Van Kessel, A.L.4
  • 5
    • 85025370531 scopus 로고    scopus 로고
    • IL-482 CO-Oximeter Operator’s Manual
    • IL-482 CO-Oximeter Operator’s Manual.
  • 6
    • 85025328298 scopus 로고    scopus 로고
    • IL-682 CO-Oximeter Operator’s Manual
    • IL-682 CO-Oximeter Operator’s Manual.
  • 7
    • 0001302058 scopus 로고
    • Determination of carbon monoxide in blood by gas chromatography
    • Collison H.A., Rodkey F.L. and O’Neal J.D. Determination of carbon monoxide in blood by gas chromatography. Clin. Chem. 1968; 14(2): 162-171.
    • (1968) Clin. Chem , vol.14 , Issue.2 , pp. 162-171
    • Collison, H.A.1    Rodkey, F.L.2    O’Neal, J.D.3
  • 8
    • 0030608454 scopus 로고    scopus 로고
    • Methodologic considerations in the interpretation of postmortem carboxyhemoglobin concentrations
    • Levine B., D’Nicuola J., Kunsman G., Smith M. and Stahl C. Methodologic considerations in the interpretation of postmortem carboxyhemoglobin concentrations. Toxicol. 1996; 115: 129-134.
    • (1996) Toxicol , vol.115 , pp. 129-134
    • Levine, B.1    D’Nicuola, J.2    Kunsman, G.3    Smith, M.4    Stahl, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.