메뉴 건너뛰기




Volumn 32, Issue 6, 1997, Pages 363-367

Digital chest imaging using a selenium detector: The impact of hard copy size on observer performance: a computed tomography-controlled study

Author keywords

comparative studies radiography; digital; Lung; radiography; thorax

Indexed keywords

SELENIUM;

EID: 0030926107     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004424-199706000-00008     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 0003994609 scopus 로고
    • Clinical evaluation of a new digital chest imaging system
    • van Heesewijk JPM, de Valois JC. Clinical evaluation of a new digital chest imaging system. Eur Radiol 1995;5:83-87.
    • (1995) Eur Radiol , vol.5 , pp. 83-87
    • Van Heesewijk, J.P.M.1    De Valois, J.C.2
  • 2
    • 0028957128 scopus 로고
    • Technical evaluation of a digital chest radiography system that uses a selenium detector
    • Chotas HG, Floyd Jr CE, Ravin CE. Technical evaluation of a digital chest radiography system that uses a selenium detector. Radiology 1995;195:264-270.
    • (1995) Radiology , vol.195 , pp. 264-270
    • Chotas, H.G.1    Floyd C.E., Jr.2    Ravin, C.E.3
  • 3
    • 0028227069 scopus 로고
    • Image quality of a digital chest radiography system based on a selenium detector
    • Neitzel U, Maack I, Günther-Kohfahl S. Image quality of a digital chest radiography system based on a selenium detector. Med Phys 1994;21:509-516.
    • (1994) Med Phys , vol.21 , pp. 509-516
    • Neitzel, U.1    Maack, I.2    Günther-Kohfahl, S.3
  • 4
    • 0029143641 scopus 로고
    • Digital chest imaging using a selenium detector: Comparison with conventional radiography for visualization of specific anatomic regions of the chest
    • van Heesewijk HPM, Neitzel U, van der Graaf Y, de Valois JC, Feldberg MAM. Digital chest imaging using a selenium detector: Comparison with conventional radiography for visualization of specific anatomic regions of the chest. AJR Am J Roentgenol 1995; 165:535-540.
    • (1995) AJR am J Roentgenol , vol.165 , pp. 535-540
    • Van Heesewijk, H.P.M.1    Neitzel, U.2    Van der Graaf, Y.3    De Valois, J.C.4    Feldberg, M.5
  • 5
    • 0028997552 scopus 로고
    • Digital chest imaging using a selenium detector: A simulated diffuse interstitial pulmonary disease detection study
    • van Heesewijk HPM, van der Graaf Y, de Valois JC, Feldberg MAM. Digital chest imaging using a selenium detector: A simulated diffuse interstitial pulmonary disease detection study. Invest Radiol 1995;5:300-305.
    • (1995) Invest Radiol , vol.5 , pp. 300-305
    • Van Heesewijk, H.P.M.1    Van der Graaf, Y.2    De Valois, J.C.3    Feldberg, M.A.M.4
  • 6
    • 0028825353 scopus 로고
    • Selenium-based digital radiography of the chest: Radiologists' preference compared with film-screen radiographs
    • Floyd CE, Baker JA, Chotas HG, Ravin C. Selenium-based digital radiography of the chest: Radiologists' preference compared with film-screen radiographs. AJR Am J Roentgenol 1995; 165:1353-1358.
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 1353-1358
    • Floyd, C.E.1    Baker, J.A.2    Chotas, H.G.3    Ravin, C.4
  • 7
    • 0029808231 scopus 로고    scopus 로고
    • Digital chest imaging using a selenium detector versus conventional film radiography: A CT-controlled study
    • van Heesewijk JPM, van der Graaf Y, Vos JA, de Valois JC, Feldberg MAM. Digital chest imaging using a selenium detector versus conventional film radiography: A CT-controlled study. Radiology 1996; 200:687-690.
    • (1996) Radiology , vol.200 , pp. 687-690
    • Van Heesewijk, J.P.M.1    Van der Graaf, Y.2    Vos, J.A.3    De Valois, J.C.4    Feldberg, M.A.M.5
  • 8
    • 0026752629 scopus 로고
    • Impact of hardcopy size on observer performance in digital chest radiography
    • Schaefer CM, Prokop M, Oestmann JW, et al. Impact of hardcopy size on observer performance in digital chest radiography. Radiology 1992;184:77-81.
    • (1992) Radiology , vol.184 , pp. 77-81
    • Schaefer, C.M.1    Prokop, M.2    Oestmann, J.W.3
  • 9
    • 0025008969 scopus 로고
    • Digital storage phosphor imaging versus conventional film radiography in CT-documented chest disease
    • Schaefer CM, Greene R, Oestmann JE, et al, Digital storage phosphor imaging versus conventional film radiography in CT-documented chest disease. Radiology 1990: 174:207-210.
    • (1990) Radiology , vol.174 , pp. 207-210
    • Schaefer, C.M.1    Greene, R.2    Oestmann, J.E.3
  • 10
    • 0026689155 scopus 로고
    • Grids or air gaps for scatter reduction in digital radiography: A model calculation
    • Neitzel U. Grids or air gaps for scatter reduction in digital radiography: A model calculation. Med Phys 1992;19:475-481.
    • (1992) Med Phys , vol.19 , pp. 475-481
    • Neitzel, U.1
  • 11
    • 0024511244 scopus 로고
    • Some practical issues of experimental design and data analysis in radiological ROC studies
    • Metz CE. Some practical issues of experimental design and data analysis in radiological ROC studies. Invest Radiol 1989; 24:234-245.
    • (1989) Invest Radiol , vol.24 , pp. 234-245
    • Metz, C.E.1
  • 13
    • 0029744109 scopus 로고    scopus 로고
    • Economic aspects and cost calculations for a digital selenium- Based chest imaging system
    • de Valois JC, van Heesewijk HPM. Economic aspects and cost calculations for a digital selenium- based chest imaging system. AJR Am J Roentgenol 1996;167:950-952.
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 950-952
    • De Valois, J.C.1    Van Heesewijk, H.P.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.