메뉴 건너뛰기




Volumn 4, Issue 6, 1997, Pages 568-573

Bioimpedance cardiac output measurements in patients with presumed congestive heart failure

Author keywords

Cardiac output; Cardiography; Congestive heart failure; Critical care; Emergency services; Impedance; Monitoring

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; CONGESTIVE HEART FAILURE; ECHOCARDIOGRAPHY; HEART DILATATION; HEART OUTPUT; HEART RIGHT VENTRICLE HYPERTROPHY; HEMODYNAMIC MONITORING; HUMAN; HYPERTROPHIC CARDIOMYOPATHY; IMPEDANCE; ISCHEMIC HEART DISEASE; MALE; PATIENT MONITORING; PERICARDIAL EFFUSION; PRIORITY JOURNAL;

EID: 0030922075     PISSN: 10696563     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1553-2712.1997.tb03580.x     Document Type: Article
Times cited : (13)

References (13)
  • 1
    • 0022979027 scopus 로고
    • Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance
    • Bernstein DP. Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. Crit Care Med. 1986; 14:898-901.
    • (1986) Crit Care Med , vol.14 , pp. 898-901
    • Bernstein, D.P.1
  • 2
    • 0009679354 scopus 로고
    • Noninvasive cardiac output measurement
    • Shoemaker WC, Ayers S, Grenvik A, et al. Philadelphia: W.B Saunders
    • Bernstein DP. Noninvasive cardiac output measurement. In: Shoemaker WC, Ayers S, Grenvik A, et al. Textbook of Critical Care, 2nd edition. Philadelphia: W.B Saunders, 1989, pp 159-85.
    • (1989) Textbook of Critical Care, 2nd Edition , pp. 159-185
    • Bernstein, D.P.1
  • 3
    • 0024405426 scopus 로고
    • Feasibility of non-invasive physiologic monitoring in resuscitation of trauma patients in the emergency department
    • Lopez-Saucedo A, Hirt M, Appel PL, Curtis DL. Feasibility of non-invasive physiologic monitoring in resuscitation of trauma patients in the emergency department Crit Care Med. 1989; 17:567-8.
    • (1989) Crit Care Med , vol.17 , pp. 567-568
    • Lopez-Saucedo, A.1    Hirt, M.2    Appel, P.L.3    Curtis, D.L.4
  • 4
    • 0027415523 scopus 로고
    • Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness
    • Wo CCJ, Shoemaker WC, Appel PL, Bishop MH, Dram HB, Hardin E. Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness. Crit Care Med. 1993; 21:218-23.
    • (1993) Crit Care Med , vol.21 , pp. 218-223
    • Wo, C.C.J.1    Shoemaker, W.C.2    Appel, P.L.3    Bishop, M.H.4    Dram, H.B.5    Hardin, E.6
  • 8
    • 0027458319 scopus 로고
    • Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis
    • Young JD, McQuillan P. Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis. Br J Anaesth. 1993; 70:58-62.
    • (1993) Br J Anaesth , vol.70 , pp. 58-62
    • Young, J.D.1    McQuillan, P.2
  • 9
    • 0026409914 scopus 로고
    • Noninvasive measurement of cardiac output by thoracic electrical bioimpedance: A study of reproducibility and comparison with thermodilution
    • Jewkes C, Sear JW, Verhoeff F, Sanders DJ, Foex P Noninvasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution. Br J Anaesth. 1991; 67:788-94.
    • (1991) Br J Anaesth , vol.67 , pp. 788-794
    • Jewkes, C.1    Sear, J.W.2    Verhoeff, F.3    Sanders, D.J.4    Foex, P.5
  • 10
    • 0025330258 scopus 로고
    • Trending of impedance monitored cardiac variables: Methods and statistical power analysis of 100 control studies in a pediatric intensive care unit
    • Mickell JJ, Lucking SE, Chaten FC, et al. Trending of impedance monitored cardiac variables: methods and statistical power analysis of 100 control studies in a pediatric intensive care unit. Crit Care Med. 1990; 18:645-50.
    • (1990) Crit Care Med , vol.18 , pp. 645-650
    • Mickell, J.J.1    Lucking, S.E.2    Chaten, F.C.3
  • 11
    • 0027216287 scopus 로고
    • Bioimpedance measurement of body water correlates with measured volume balance in injured patients
    • Rosemurgy AS, Rodriguez E, Hart MB, Kurto HZ, Albrink MH. Bioimpedance measurement of body water correlates with measured volume balance in injured patients. South Med J. 1993; 86:651-3.
    • (1993) South Med J , vol.86 , pp. 651-653
    • Rosemurgy, A.S.1    Rodriguez, E.2    Hart, M.B.3    Kurto, H.Z.4    Albrink, M.H.5
  • 12
    • 0027511641 scopus 로고
    • Bioimpedance monitoring of rehydration in cholera
    • McDonald JJ, Chanduvi B, Velarde G. Bioimpedance monitoring of rehydration in cholera. Lancet. 1993; 341:1049-51
    • (1993) Lancet , vol.341 , pp. 1049-1051
    • McDonald, J.J.1    Chanduvi, B.2    Velarde, G.3
  • 13
    • 0028840609 scopus 로고
    • Comparison of cardiac output by thoracic electrical bioimpedance in critically ill and non-critically ill patients
    • Weiss SJ, Calloway E, Cairo J, Granger W, Winslow J. Comparison of cardiac output by thoracic electrical bioimpedance in critically ill and non-critically ill patients. Am J Emerg Med. 1995; 13:626-31.
    • (1995) Am J Emerg Med , vol.13 , pp. 626-631
    • Weiss, S.J.1    Calloway, E.2    Cairo, J.3    Granger, W.4    Winslow, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.