메뉴 건너뛰기




Volumn 3, Issue 2, 1997, Pages 107-113

In vitro calibration of the capacitance method (Corneometer CM 825) and conductance method (Skicon-200) for the evaluation of the hydration state of the skin

Author keywords

Calibration; Capacitance; Conductance; Hydration

Indexed keywords

CELLULOSE;

EID: 0030920518     PISSN: 0909752X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1600-0846.1997.tb00171.x     Document Type: Article
Times cited : (60)

References (15)
  • 1
    • 0001560553 scopus 로고
    • Impedance methods for studying skin moisturization
    • Lévêque JL, de Rigal J. Impedance methods for studying skin moisturization. J Soc Cosmet Chem 1983: 34: 419-428.
    • (1983) J Soc Cosmet Chem , vol.34 , pp. 419-428
    • Lévêque, J.L.1    De Rigal, J.2
  • 4
    • 0001772384 scopus 로고
    • Impedance measurements for evaluation of the hydration state of the skin surface
    • Lévêque, JL, ed. New York: Marcel Dekker
    • Tagami H. Impedance measurements for evaluation of the hydration state of the skin surface. In: Lévêque, JL, ed. Cutaneous investigation in health and disease, noninvasive methods and instrumentation. New York: Marcel Dekker, 1989: 79-111.
    • (1989) Cutaneous Investigation in Health and Disease, Noninvasive Methods and Instrumentation , pp. 79-111
    • Tagami, H.1
  • 5
    • 0343687802 scopus 로고
    • Non-invasive electrical measurements for evaluating the water content of the horny layer: Comparison between capacitance and conductance measurement
    • Scott RC, Gray RH, Hadgraft J, Bodde HE, eds. London: IBC Technical Services
    • Barel, AO, Clarys P, Wessels B, de Romsée A. Non-invasive electrical measurements for evaluating the water content of the horny layer: comparison between capacitance and conductance measurement. In Scott RC, Gray RH, Hadgraft J, Bodde HE, eds. Prediction of percutaneous penetation. Methods, measurements, modelling. London: IBC Technical Services, 1991: 238-247.
    • (1991) Prediction of Percutaneous Penetation. Methods, Measurements, Modelling , pp. 238-247
    • Barel, A.O.1    Clarys, P.2    Wessels, B.3    De Romsée, A.4
  • 6
    • 0002926031 scopus 로고
    • Measuring of epidermal capacitance
    • Serup J, Jemec GBE, eds. Boca Raton: CRC Press
    • Barel AO, Clarys P. Measuring of epidermal capacitance. In: Serup J, Jemec GBE, eds. Handbook of non-invasive methods and the skin. Boca Raton: CRC Press, 1995: 165-170.
    • (1995) Handbook of Non-invasive Methods and the Skin , pp. 165-170
    • Barel, A.O.1    Clarys, P.2
  • 7
    • 0002899417 scopus 로고
    • Hardware and measuring principle: Corneometer
    • Elsner P, Berardesca E, Maibach HI, eds. Boca Raton: CRC Press
    • Courage W. Hardware and measuring principle: Corneometer. In: Elsner P, Berardesca E, Maibach HI, eds. Bioengineering and the skin: water and the stratum corneum. Boca Raton: CRC Press, 1994: 171-175.
    • (1994) Bioengineering and the Skin: Water and the Stratum Corneum , pp. 171-175
    • Courage, W.1
  • 9
    • 0002899418 scopus 로고
    • Hardware and measuring principle: Skin conductance
    • Elsner P, Berardesca E, Maibach HI, eds. Boca Raton: CRC Press
    • Tagami H. Hardware and measuring principle: skin conductance. In: Elsner P, Berardesca E, Maibach HI, eds. Bioengineering and the skin: water and the stratum corneum. Boca Raton: CRC Press, 1994: 197-203.
    • (1994) Bioengineering and the Skin: Water and the Stratum Corneum , pp. 197-203
    • Tagami, H.1
  • 10
    • 0002579788 scopus 로고
    • Measuring of the electrical conductance and impedance
    • Serup J, Jemec GBE, eds. Boca Raton: CRC Press
    • Tagami H. Measuring of the electrical conductance and impedance. In: Serup J, Jemec GBE, eds. Handbook of non-invasive methods and the skin. Boca Raton: CRC Press, 1995: 159-164.
    • (1995) Handbook of Non-invasive Methods and the Skin , pp. 159-164
    • Tagami, H.1
  • 12
    • 12644253131 scopus 로고    scopus 로고
    • Personal communication
    • Barel AR. Personal communication. 1996.
    • (1996)
    • Barel, A.R.1
  • 13
    • 0023707113 scopus 로고
    • Assessment of skin moisture. Measurement of electrical conductance, capacitance and transepidermal water loss
    • Blichman CW, Serup J. Assessment of skin moisture. Measurement of electrical conductance, capacitance and transepidermal water loss. Acta Derm Venereol 1988: 68: 284-290.
    • (1988) Acta Derm Venereol , vol.68 , pp. 284-290
    • Blichman, C.W.1    Serup, J.2
  • 14
    • 0000030456 scopus 로고
    • Hardware and measuring principle: The nova™ DPM 9003
    • Elsner P, Berardesca E, Maibach HI, eds. Boca Raton: CRC Press
    • Gabard B, Treffel P. Hardware and measuring principle: the nova™ DPM 9003. In: Elsner P, Berardesca E, Maibach HI, eds. Bioengineering and the skin: water and the stratum corneum. Boca Raton: CRC Press, 1994: 177-193.
    • (1994) Bioengineering and the Skin: Water and the Stratum Corneum , pp. 177-193
    • Gabard, B.1    Treffel, P.2
  • 15
    • 0025873139 scopus 로고
    • Comparative study of normal and rough human skin hydration in vivo: Evaluation with four different instruments
    • Van Neste D. Comparative study of normal and rough human skin hydration in vivo: evaluation with four different instruments. J Dermatol Sci 1991: 2: 119-124.
    • (1991) J Dermatol Sci , vol.2 , pp. 119-124
    • Van Neste, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.