메뉴 건너뛰기




Volumn 79, Issue 9, 1997, Pages 1279-1280

Transcatheter closure of patent ductus arteriosus using coils

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; ARTIFICIAL EMBOLISM; CHILD; CLINICAL ARTICLE; DEVICE; HEART CATHETERIZATION; HUMAN; INFANT; NEWBORN; PATENT DUCTUS ARTERIOSUS; PREOPERATIVE EVALUATION; PRIORITY JOURNAL;

EID: 0030918270     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(97)00102-1     Document Type: Article
Times cited : (41)

References (10)
  • 3
    • 0028092055 scopus 로고
    • Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils
    • Hijazi ZM, Geggel RL. Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils. Am J Cardiol 1994;74:925-929.
    • (1994) Am J Cardiol , vol.74 , pp. 925-929
    • Hijazi, Z.M.1    Geggel, R.L.2
  • 4
    • 0029965576 scopus 로고    scopus 로고
    • Transcatheter closure with single or multiple Gianturco coils of patent ductus arteriosus in infants weighing ≤8 kg: Retrograde versus antegrade approach
    • Hijazi ZM, Lloyd TR, Beekman RH III, Geggel RL. Transcatheter closure with single or multiple Gianturco coils of patent ductus arteriosus in infants weighing ≤8 kg: retrograde versus antegrade approach. Am Heart J 1996;132:827-835.
    • (1996) Am Heart J , vol.132 , pp. 827-835
    • Hijazi, Z.M.1    Lloyd, T.R.2    Beekman III, R.H.3    Geggel, R.L.4
  • 5
    • 0027967761 scopus 로고
    • Use of preformed nitinol snare to improve transcather coil delivery in occlusion of patent ductus arteriosus
    • Sommer RJ, Gutierrez A, Lai WW, Parness IA. Use of preformed nitinol snare to improve transcather coil delivery in occlusion of patent ductus arteriosus. Am J Cardiol 1994;74:836-839.
    • (1994) Am J Cardiol , vol.74 , pp. 836-839
    • Sommer, R.J.1    Gutierrez, A.2    Lai, W.W.3    Parness, I.A.4
  • 6
    • 0030023825 scopus 로고    scopus 로고
    • Transcatheter closure of the patent ductus arteriosus: Comparison between the Rashkind occluder device and the anterograde Gianturco coils technique
    • Galal O, de Moor M, Al-Fadley F, Hijazi ZM. Transcatheter closure of the patent ductus arteriosus: comparison between the Rashkind occluder device and the anterograde Gianturco coils technique. Am Heart J 1996;131:368-373.
    • (1996) Am Heart J , vol.131 , pp. 368-373
    • Galal, O.1    De Moor, M.2    Al-Fadley, F.3    Hijazi, Z.M.4
  • 9
    • 0024841969 scopus 로고
    • Two-dimensional echocardiographic and color flow Doppler evaluation of ductal occlusion with the Rashkind prosthesis
    • Musewe NN, Benson LN, Smallhorn JF, Freedom RM. Two-dimensional echocardiographic and color flow Doppler evaluation of ductal occlusion with the Rashkind prosthesis. Circulation 1989;80:1706-1710.
    • (1989) Circulation , vol.80 , pp. 1706-1710
    • Musewe, N.N.1    Benson, L.N.2    Smallhorn, J.F.3    Freedom, R.M.4
  • 10
    • 0019979245 scopus 로고
    • Suprasternal cross-sectional echocardiography in assessment of patent ductus arteriosus
    • Smallhorn JF, Huhta JC, Anderson RH, Macartney FJ. Suprasternal cross-sectional echocardiography in assessment of patent ductus arteriosus. Br Heart J 1982;48:321-330.
    • (1982) Br Heart J , vol.48 , pp. 321-330
    • Smallhorn, J.F.1    Huhta, J.C.2    Anderson, R.H.3    Macartney, F.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.