메뉴 건너뛰기




Volumn 166, Issue 5, 1997, Pages 376-381

Analysis of reject x-ray films as quality assurance element in diagnostic radiology;Analyse verworfenen Filmmaterials als Element der Qualitatssicherung in der Diagnostischen Radiologie

Author keywords

images; quality assurance; radiography; reject film

Indexed keywords

ARTICLE; CONTROLLED STUDY; HEALTH CARE COST; HUMAN; IMAGE QUALITY; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; QUALITY CONTROL; RADIOGRAPHY;

EID: 0030916135     PISSN: 09366652     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (12)
  • 1
    • 0021488316 scopus 로고
    • Reject analysis: Its role in quality assurance
    • Watkinson, S., B. M. Moores, S. J. Hill: Reject analysis: its role in quality assurance. Radiography 50 (1984) 593
    • (1984) Radiography , vol.50 , pp. 593
    • Watkinson, S.1    Moores, B.M.2    Hill, S.J.3
  • 3
    • 0016211077 scopus 로고
    • The incidence and causes of repeated radiographic examinations in a community hospital
    • Mazzaferro, R. J., S. Baiter, M. L. Janover: The incidence and causes of repeated radiographic examinations in a community hospital. Radiology 112 (1974) 71-72
    • (1974) Radiology , vol.112 , pp. 71-72
    • Mazzaferro, R.J.1    Baiter, S.2    Janover, M.L.3
  • 4
    • 0017472355 scopus 로고
    • Spoilt films in X-ray departements. Correspondence
    • McKinlay, A., B. McCauley: Spoilt films in X-ray departements. Correspondence. Brit. J. Radiol. 50 (1977) 233-234
    • (1977) Brit. J. Radiol. , vol.50 , pp. 233-234
    • McKinlay, A.1    McCauley, B.2
  • 5
    • 0025583827 scopus 로고
    • Quality assurance in diagnostic radiology - For its own sake or that of the patient
    • Henshaw, E. T.: Quality assurance in diagnostic radiology - for its own sake or that of the patient. Quality Assurance in Health Care 2 (1990) 213-218
    • (1990) Quality Assurance in Health Care , vol.2 , pp. 213-218
    • Henshaw, E.T.1
  • 6
    • 0014603596 scopus 로고
    • Repeats - An aspect of departmental management
    • Bourne, D.: Repeats - an aspect of departmental management. Radiography 35 (1969) 257-261
    • (1969) Radiography , vol.35 , pp. 257-261
    • Bourne, D.1
  • 8
    • 0000199683 scopus 로고
    • Leitlinien zur Qualitätssicherung in der Röntgendiagnostik
    • Verlautbarung der deutschen Bundesärztekammer: Leitlinien zur Qualitätssicherung in der Röntgendiagnostik. Dtsch. Ärzteblatt 92 (1995) 1691-1702
    • (1995) Dtsch. Ärzteblatt , vol.92 , pp. 1691-1702
  • 10
    • 0023077970 scopus 로고
    • Analyse von Wiederv holungsaufnahmen in der Röntgendiagnostik
    • Brandt, G. A., H.-J. Preuß, P. Leinweber: Analyse von Wiederv holungsaufnahmen in der Röntgendiagnostik. Radiol. Diagn. 28 (1987) 271-277
    • (1987) Radiol. Diagn. , vol.28 , pp. 271-277
    • Brandt, G.A.1    Preuß, H.-J.2    Leinweber, P.3
  • 11
    • 0022615796 scopus 로고
    • Analyse eines Qualitätssicherungsprogramms
    • Göthlin, J. H.: Analyse eines Qualitätssicherungsprogramms. Radiol. Diagn. 27 (1986) 45
    • (1986) Radiol. Diagn. , vol.27 , pp. 45
    • Göthlin, J.H.1
  • 12
    • 0342781150 scopus 로고
    • Erfassung und Analyse des Filmausschusses in einer Röntgenabteilung
    • Stargardt, A.: Erfassung und Analyse des Filmausschusses in einer Röntgenabteilung. Moderne Röntgenphotographie 2 (1983) 26-28
    • (1983) Moderne Röntgenphotographie , vol.2 , pp. 26-28
    • Stargardt, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.