-
1
-
-
0027324582
-
Auditory brainstem implant: I. Issues in surgical implantation
-
Brackmann DE, Hitselberger WE, Nelson RA, Moore J, Waring MD, Portillo F, et al. Auditory brainstem implant: I. Issues in surgical implantation. Otolaryngol Head Neck Surg 1993; 108: 624-33.
-
(1993)
Otolaryngol Head Neck Surg
, vol.108
, pp. 624-633
-
-
Brackmann, D.E.1
Hitselberger, W.E.2
Nelson, R.A.3
Moore, J.4
Waring, M.D.5
Portillo, F.6
-
3
-
-
0023367193
-
Electrical Stimulation of the auditory brain stem structure in deafened adults
-
Eisenberg LS, Maltan AA, Portillo F, Mobley JP, House WF. Electrical Stimulation of the auditory brain stem structure in deafened adults. J Rehabil Res Dev 1987; 24: 9-22.
-
(1987)
J Rehabil Res Dev
, vol.24
, pp. 9-22
-
-
Eisenberg, L.S.1
Maltan, A.A.2
Portillo, F.3
Mobley, J.P.4
House, W.F.5
-
4
-
-
0022272658
-
Electrical activation of cochlcar nucleus in man
-
McElveen J, Hitselberger W, House WF, Mobley JP, Terr L. Electrical activation of cochlcar nucleus in man. Am J Otol 1985; 6 Suppl: 88-91.
-
(1985)
Am J Otol
, vol.6
, Issue.SUPPL.
, pp. 88-91
-
-
McElveen, J.1
Hitselberger, W.2
House, W.F.3
Mobley, J.P.4
Terr, L.5
-
5
-
-
0027762359
-
Auditory brain stem implant: Electrical stimulation of the human cochlear nucleus
-
Fraysse B, Deguine O, editors. Cochlear implants. New prespectives. Basel: Karger
-
Portillo F, Nelson RA, Brackmann DE, Hitselberger WE, Shannon RV, Waring MD, Moore JK. Auditory brain stem implant: electrical stimulation of the human cochlear nucleus. In: Fraysse B, Deguine O, editors. Cochlear implants. New prespectives. Adv Otorhinolaryngol. Basel: Karger, 1993, vol. 48, pp. 248-252.
-
(1993)
Adv Otorhinolaryngol
, vol.48
, pp. 248-252
-
-
Portillo, F.1
Nelson, R.A.2
De Brackmann3
Hitselberger, W.E.4
Shannon, R.V.5
Waring, M.D.6
Moore, J.K.7
-
6
-
-
0027314771
-
Auditory brainstem implant. II Postsurgical issues and performance
-
Shannon RV, Fayad J, Moore J, Lo WWM, Otto S, Nelson R, O'leary M. Auditory brainstem implant. II Postsurgical issues and performance. Otolaryngol Head Neck Surg 1993; 108: 634-42.
-
(1993)
Otolaryngol Head Neck Surg
, vol.108
, pp. 634-642
-
-
Shannon, R.V.1
Fayad, J.2
Moore, J.3
Lo, W.W.M.4
Otto, S.5
Nelson, R.6
O'Leary, M.7
-
7
-
-
0026075919
-
Surgical and safety considerations of multichannel cochlear implants in children
-
Suppl.
-
Clark GM, Cohen NL, Shepherd RK. Surgical and safety considerations of multichannel cochlear implants in children. Ear Hear 1991; 12: 17s-24s Suppl.
-
(1991)
Ear Hear
, vol.12
-
-
Clark, G.M.1
Cohen, N.L.2
Shepherd, R.K.3
-
8
-
-
0023694301
-
The histophathology of the human temporal bone and auditory central nervous system following cochlear implantation in a patient: Correlation with psychophysical and speech perception results
-
Clark GM, Shepherd RK, Franz BK-H, Dowell RC, Tong YC, Blarney PJ, et al. The histophathology of the human temporal bone and auditory central nervous system following cochlear implantation in a patient: correlation with psychophysical and speech perception results. Acta Otolaryngol 1988; 448 suppl: 1-65.
-
(1988)
Acta Otolaryngol
, vol.448
, Issue.SUPPL.
, pp. 1-65
-
-
Clark, G.M.1
Shepherd, R.K.2
Franz, B.K.-H.3
Dowell, R.C.4
Tong, Y.C.5
Blarney, P.J.6
-
9
-
-
0003082312
-
The biocompatibility and safety of cochlear prostheses
-
Clark GM et al. editors. Edinburgh: Churchill-Livingstone
-
Shepherd RK, Franz BK-HG, Clark GM. The biocompatibility and safety of cochlear prostheses. In: Clark GM et al. editors. Cochlear prostheses. Edinburgh: Churchill-Livingstone 1990: 69-98.
-
(1990)
Cochlear Prostheses
, pp. 69-98
-
-
Shepherd, R.K.1
Franz, B.K.-H.G.2
Clark, G.M.3
-
10
-
-
0028788871
-
Reduction in excitability of the auditory nerve following electrical stimulation at high stimulus rates
-
Tykocinski M, Shepherd RK, Clark GM. Reduction in excitability of the auditory nerve following electrical stimulation at high stimulus rates. Hear Res 1995; 88: 124-42.
-
(1995)
Hear Res
, vol.88
, pp. 124-142
-
-
Tykocinski, M.1
Shepherd, R.K.2
Clark, G.M.3
-
11
-
-
0025739221
-
Chronic intracochlear electrical stimulation induces selective survival of spiral ganglion neurons in neonatally deafened cats
-
Leake PA, Hradek GT, Rebscher SJ, Snyder RL. Chronic intracochlear electrical stimulation induces selective survival of spiral ganglion neurons in neonatally deafened cats. Hear Res 1991; 54: 251-71.
-
(1991)
Hear Res
, vol.54
, pp. 251-271
-
-
Leake, P.A.1
Hradek, G.T.2
Rebscher, S.J.3
Snyder, R.L.4
-
12
-
-
0024453996
-
Biocompatibility of the central electroauditory prosthesis and the human cochlear nuclei
-
Terr LI, Mobley JP, House WF. Biocompatibility of the central electroauditory prosthesis and the human cochlear nuclei. Am J Oto 1989; 10: 339-42.
-
(1989)
Am J Oto
, vol.10
, pp. 339-342
-
-
Terr, L.I.1
Mobley, J.P.2
House, W.F.3
-
13
-
-
0024791169
-
Surgical implantation and biocompatibility of central nervous system auditory prosthesis
-
Niparko JK, Altschuler RA, Xue X, Wiler JA, Anderson DJ. Surgical implantation and biocompatibility of central nervous system auditory prosthesis. Ann Otol Rhinol Laryngol 1989; 98: 965-70.
-
(1989)
Ann Otol Rhinol Laryngol
, vol.98
, pp. 965-970
-
-
Niparko, J.K.1
Altschuler, R.A.2
Xue, X.3
Wiler, J.A.4
Anderson, D.J.5
-
14
-
-
0024454373
-
Auditory brainstem prosthesis: Biocompatibility of stimulation
-
Niparko JK, Altschuler RA, Evans DA, Xue X, Farraye J, Anderson DJ. Auditory brainstem prosthesis: biocompatibility of stimulation. Otolaryngol Head Neck Surg 1989; 101: 344-52.
-
(1989)
Otolaryngol Head Neck Surg
, vol.101
, pp. 344-352
-
-
Niparko, J.K.1
Altschuler, R.A.2
Evans, D.A.3
Xue, X.4
Farraye, J.5
Anderson, D.J.6
-
15
-
-
0026757583
-
Stimulation with chronically implanted microelectrode in the cochlear nucleus of the cat: Histologic and physiologic effects
-
McCreery DB, Yuen TGH, Agnew WF, Bullara LA. Stimulation with chronically implanted microelectrode in the cochlear nucleus of the cat: histologic and physiologic effects. Hear Res 1992; 62: 42-56.
-
(1992)
Hear Res
, vol.62
, pp. 42-56
-
-
McCreery, D.B.1
Yuen, T.G.H.2
Agnew, W.F.3
Bullara, L.A.4
-
16
-
-
0028300612
-
Stimulus parameters affecting tissue injury during microstimulation in the cochlear nucleus of the cat
-
McCreery DB, Yuen TGH, Agnew WF, Bullara LA. Stimulus parameters affecting tissue injury during microstimulation in the cochlear nucleus of the cat. Hear Res 1994; 77: 105-15.
-
(1994)
Hear Res
, vol.77
, pp. 105-115
-
-
McCreery, D.B.1
Yuen, T.G.H.2
Agnew, W.F.3
Bullara, L.A.4
-
17
-
-
0022590563
-
Histopathologic evaluation of prolonged intracortical electrical stimulation
-
Agnew W, Yuen T, McCreery D, Bullara L. Histopathologic evaluation of prolonged intracortical electrical stimulation. Exp Neurol 1986; 92: 162-85.
-
(1986)
Exp Neurol
, vol.92
, pp. 162-185
-
-
Agnew, W.1
Yuen, T.2
McCreery, D.3
Bullara, L.4
-
18
-
-
0022611152
-
Neuronal activity evoked by chronically implanted intracortical microelectrodes
-
McCreery DB, Bullara LA, Agnew WF. Neuronal activity evoked by chronically implanted intracortical microelectrodes. Exp Neurol 1986; 92: 147-61.
-
(1986)
Exp Neurol
, vol.92
, pp. 147-161
-
-
McCreery, D.B.1
Bullara, L.A.2
Agnew, W.F.3
-
19
-
-
0028855182
-
Auditory brain-stem responses evoked by electrical stimulation of the cochlear nucleus in human subjects
-
Waring MD. Auditory brain-stem responses evoked by electrical stimulation of the cochlear nucleus in human subjects. Electroencephalogr Clin Neurophysiol 1995; 96: 338-47.
-
(1995)
Electroencephalogr Clin Neurophysiol
, vol.96
, pp. 338-347
-
-
Waring, M.D.1
-
20
-
-
0023124728
-
Effect of high electrical stimulus intensities on the auditory nerve using brain stem response audiometry
-
Shepherd RK, Clark GM. Effect of high electrical stimulus intensities on the auditory nerve using brain stem response audiometry. Ann Otol Rhinol Larygnol 1987; 128 Suppl: 50-2.
-
(1987)
Ann Otol Rhinol Larygnol
, vol.128
, Issue.SUPPL.
, pp. 50-52
-
-
Shepherd, R.K.1
Clark, G.M.2
-
21
-
-
0025957768
-
Electrically evoked brainstem response: Growth of response with current level
-
Abbas PJ, Brown CJ: Electrically evoked brainstem response: growth of response with current level. Hear Res 1991; 51: 123-38.
-
(1991)
Hear Res
, vol.51
, pp. 123-138
-
-
Abbas, P.J.1
Brown, C.J.2
-
22
-
-
0028595934
-
Adaptation in the compound action potential response of the guinea pig VIIIth nerve to electrical stimulation
-
Killian MJP, Klis SFL, Smoorenburg GF. Adaptation in the compound action potential response of the guinea pig VIIIth nerve to electrical stimulation. Hear Res 1994; 81: 66-82.
-
(1994)
Hear Res
, vol.81
, pp. 66-82
-
-
Killian, M.J.P.1
Klis, S.F.L.2
Smoorenburg, G.F.3
-
23
-
-
0017706171
-
Electrophysiological studies of long-term electrical stimulation of the cerebellum in monkeys
-
Babb TL, Soper HV, Lieb JP, Brown WJ, Ottino CA, Crandl PH. Electrophysiological studies of long-term electrical stimulation of the cerebellum in monkeys. J Neurosurg 1977; 47: 353-65.
-
(1977)
J Neurosurg
, vol.47
, pp. 353-365
-
-
Babb, T.L.1
Soper, H.V.2
Lieb, J.P.3
Brown, W.J.4
Ottino, C.A.5
Crandl, P.H.6
-
24
-
-
0017755945
-
Tissue reactions to long-term electrical stimulation of the cerebellum in monkeys
-
Brown WJ, Babb TL, Soper HV, Lieb JP, Ottino CA, Crandl PH. Tissue reactions to long-term electrical stimulation of the cerebellum in monkeys. J Neurosurg 1977; 47: 366-7.
-
(1977)
J Neurosurg
, vol.47
, pp. 366-367
-
-
Brown, W.J.1
Babb, T.L.2
Soper, H.V.3
Lieb, J.P.4
Ottino, C.A.5
Crandl, P.H.6
-
25
-
-
0003011402
-
Mechanisms of stimulation-induced neural damage and their relation to guidelines for safe stimulation
-
Agnew WF, McCreery DB. New York: Prentice Hall
-
McCreery DB, Agnew WF. Mechanisms of stimulation-induced neural damage and their relation to guidelines for safe stimulation. In: Agnew WF, McCreery DB. Neural prostheses, fundamental studies. New York: Prentice Hall, 1990: 297-317.
-
(1990)
Neural Prostheses, Fundamental Studies
, pp. 297-317
-
-
McCreery, D.B.1
Agnew, W.F.2
|