-
1
-
-
0014296409
-
The exercise electrocardiogram: Differences in interpretation
-
Blackburn H: The exercise electrocardiogram: Differences in interpretation. Am J Cardiol 1968;21:871-880
-
(1968)
Am J Cardiol
, vol.21
, pp. 871-880
-
-
Blackburn, H.1
-
2
-
-
0013834134
-
The Frank lead exercise electrocardiogram: A quantitative study based on averaging technique and digital computer analysis
-
Blomqvist G: The Frank lead exercise electrocardiogram: A quantitative study based on averaging technique and digital computer analysis. Acta Med Scand 1965;178(suppl 440):5-98
-
(1965)
Acta Med Scand
, vol.178
, Issue.SUPPL. 440
, pp. 5-98
-
-
Blomqvist, G.1
-
3
-
-
0016715653
-
ST segment isolation and quantification as a means of improving diagnostic accuracy in treadmill stress testing
-
Forlini FJ, Cohn K, Langston MF: ST segment isolation and quantification as a means of improving diagnostic accuracy in treadmill stress testing. Am Heart J 1975;90:431-438
-
(1975)
Am Heart J
, vol.90
, pp. 431-438
-
-
Forlini, F.J.1
Cohn, K.2
Langston, M.F.3
-
4
-
-
0014338421
-
Computer quantification of ST-segment response during maximal treadmill exercise
-
McHenry PL, Stowe D, Lancaster MC: Computer quantification of ST-segment response during maximal treadmill exercise. Circulation 1968;38:691-701
-
(1968)
Circulation
, vol.38
, pp. 691-701
-
-
McHenry, P.L.1
Stowe, D.2
Lancaster, M.C.3
-
5
-
-
0014610971
-
On-line analysis of the exercise electrocardiogram
-
Sheffield LT, Holt JH, Lester FM, Conroy DV, Reeves TJ: On-line analysis of the exercise electrocardiogram. Circulation 1969;40:935-944
-
(1969)
Circulation
, vol.40
, pp. 935-944
-
-
Sheffield, L.T.1
Holt, J.H.2
Lester, F.M.3
Conroy, D.V.4
Reeves, T.J.5
-
6
-
-
0024394145
-
The diagnostic accuracy of the exercise electrocardiogram: A meta-analysis of 22 years of research
-
Detrano R, Gianrossi R, Froelicher V: The diagnostic accuracy of the exercise electrocardiogram: A meta-analysis of 22 years of research. Prog Cardiovasc Dis 1989;33:173-206
-
(1989)
Prog Cardiovasc Dis
, vol.33
, pp. 173-206
-
-
Detrano, R.1
Gianrossi, R.2
Froelicher, V.3
-
7
-
-
0021833049
-
Assessment of single vessel coronary artery disease: Results of exercise electrocardiography, thallium-201 myocardial perfusion imaging and radionuclide angiography
-
Port SC, Oshima M, Ray G, McNamee P, Schmidt DH: Assessment of single vessel coronary artery disease: Results of exercise electrocardiography, thallium-201 myocardial perfusion imaging and radionuclide angiography. J Am Coll Cardiol 1985;6:75-83
-
(1985)
J Am Coll Cardiol
, vol.6
, pp. 75-83
-
-
Port, S.C.1
Oshima, M.2
Ray, G.3
McNamee, P.4
Schmidt, D.H.5
-
8
-
-
0018835482
-
The detection of coronary artery disease with radionuclide techniques: A comparison of rest-exercise thallium imaging and ejection fraction response
-
Caldwell JH, Hamilton GW, Sorensen SG, Ritchie JL, Williams DL, Kennedy JW: The detection of coronary artery disease with radionuclide techniques: A comparison of rest-exercise thallium imaging and ejection fraction response. Circulation 1980;61:610-619
-
(1980)
Circulation
, vol.61
, pp. 610-619
-
-
Caldwell, J.H.1
Hamilton, G.W.2
Sorensen, S.G.3
Ritchie, J.L.4
Williams, D.L.5
Kennedy, J.W.6
-
9
-
-
0021931918
-
Noninvasive testing in the evaluation of myocardial ischemia: Agreement among tests
-
Hammond HK, Kelly TL, Froelicher VF: Noninvasive testing in the evaluation of myocardial ischemia: Agreement among tests. J Am Coll Cardiol 1985;5:59-69
-
(1985)
J Am Coll Cardiol
, vol.5
, pp. 59-69
-
-
Hammond, H.K.1
Kelly, T.L.2
Froelicher, V.F.3
-
10
-
-
0017904495
-
Thallium-201 myocardial perfusion scintigraphy for the clinical clarification of normal, abnormal and equivocal electrocardiographic stress tests
-
Botvinick EH, Taradash MR, Shames DM, Parmley WW: Thallium-201 myocardial perfusion scintigraphy for the clinical clarification of normal, abnormal and equivocal electrocardiographic stress tests. Am J Cardiol 1978;41:43-51
-
(1978)
Am J Cardiol
, vol.41
, pp. 43-51
-
-
Botvinick, E.H.1
Taradash, M.R.2
Shames, D.M.3
Parmley, W.W.4
-
11
-
-
0021134818
-
Can areas of myocardial ischemia be localized by the exercise electrocardiogram? A correlative study with thallium-201 scintigraphy
-
Abouantoun S, Ahnve S, Savvides M, Witztum K, Jensen D, Froelicher V: Can areas of myocardial ischemia be localized by the exercise electrocardiogram? A correlative study with thallium-201 scintigraphy. Am Heart J 1984;104:933-941
-
(1984)
Am Heart J
, vol.104
, pp. 933-941
-
-
Abouantoun, S.1
Ahnve, S.2
Savvides, M.3
Witztum, K.4
Jensen, D.5
Froelicher, V.6
-
12
-
-
0017744195
-
Myocardial imaging with thallium-201 at rest and during exercise: Comparison with coronary arteriography and resting and stress electrocardiography
-
Ritchie JL, Trobaugh GB, Hamilton GW, Gould KL, Narahara KA, Murray JA, Williams DL: Myocardial imaging with thallium-201 at rest and during exercise: Comparison with coronary arteriography and resting and stress electrocardiography. Circulation 1977;56:66-71
-
(1977)
Circulation
, vol.56
, pp. 66-71
-
-
Ritchie, J.L.1
Trobaugh, G.B.2
Hamilton, G.W.3
Gould, K.L.4
Narahara, K.A.5
Murray, J.A.6
Williams, D.L.7
-
13
-
-
0020605370
-
Comparison of exercise electrocardiography, thallium 201 myocardial imaging and exercise gated blood pool scan in patients with suspected coronary artery disease
-
O'Keefe JC, Cooper RA, Edwards AC, Shuter B, Wiseman J, Donnelly GL: Comparison of exercise electrocardiography, thallium 201 myocardial imaging and exercise gated blood pool scan in patients with suspected coronary artery disease. Aust NZ J Med 1983;13:45-50
-
(1983)
Aust NZ J Med
, vol.13
, pp. 45-50
-
-
O'Keefe, J.C.1
Cooper, R.A.2
Edwards, A.C.3
Shuter, B.4
Wiseman, J.5
Donnelly, G.L.6
-
15
-
-
0023204078
-
Computer-aided electrocardiography
-
Sheffield LT: Computer-aided electrocardiography. J Am Coll Cardiol 1987;10:448-455
-
(1987)
J Am Coll Cardiol
, vol.10
, pp. 448-455
-
-
Sheffield, L.T.1
-
16
-
-
0018914066
-
Treadmill score quantifies electrocardiographic response to exercise and improves test accuracy and reproducibility
-
Hollenberg M, Budge WR, Wisneski JA, Gertz EW: Treadmill score quantifies electrocardiographic response to exercise and improves test accuracy and reproducibility. Circulation 1980;61:276-285
-
(1980)
Circulation
, vol.61
, pp. 276-285
-
-
Hollenberg, M.1
Budge, W.R.2
Wisneski, J.A.3
Gertz, E.W.4
-
17
-
-
0021016404
-
Computer analysis of exercise-induced changes in electrocardiographic variables: Comparison of methods and criteria
-
Savvides M, Ahnve S, Bhargava V, Froelicher V: Computer analysis of exercise-induced changes in electrocardiographic variables: Comparison of methods and criteria. Chest 1983;84:699-706
-
(1983)
Chest
, vol.84
, pp. 699-706
-
-
Savvides, M.1
Ahnve, S.2
Bhargava, V.3
Froelicher, V.4
-
18
-
-
0024267880
-
Computer-based ST/HR slope calculation on Marquette CASE 12: Development and technical considerations
-
Kligfield P, Okin PM, Stumpf T, Zachman D: Computer-based ST/HR slope calculation on Marquette CASE 12: Development and technical considerations. J Electrocardiol 1988;21(suppl): S134-S138
-
(1988)
J Electrocardiol
, vol.21
, Issue.SUPPL.
-
-
Kligfield, P.1
Okin, P.M.2
Stumpf, T.3
Zachman, D.4
-
19
-
-
0027375687
-
Exercise testing in women with chest pain: Applications and limitations of computer analysis
-
Walling AD, Crawford MH: Exercise testing in women with chest pain: Applications and limitations of computer analysis. Coron Art Dis 1993;4:783-789
-
(1993)
Coron Art Dis
, vol.4
, pp. 783-789
-
-
Walling, A.D.1
Crawford, M.H.2
-
20
-
-
0025735121
-
Logistic discriminant analysis improves diagnostic accuracy of exercise testing for coronary artery disease in women
-
Robert AR, Melin JA, Detry JR: Logistic discriminant analysis improves diagnostic accuracy of exercise testing for coronary artery disease in women. Circulation 1991;83:1202-1209
-
(1991)
Circulation
, vol.83
, pp. 1202-1209
-
-
Robert, A.R.1
Melin, J.A.2
Detry, J.R.3
-
21
-
-
0028268615
-
Improved criteria for localization of coronary artery disease from the exercise electrocardiogram
-
Halon DA, Mevorach D, Rodeanu M, Lewis BS: Improved criteria for localization of coronary artery disease from the exercise electrocardiogram. Cardiology 1994;84:331-338
-
(1994)
Cardiology
, vol.84
, pp. 331-338
-
-
Halon, D.A.1
Mevorach, D.2
Rodeanu, M.3
Lewis, B.S.4
-
22
-
-
0026579726
-
Application of computerized exercise ECG digitization: Interpretation in large clinical trials
-
Caralis DG, Shaw L, Bilgere B, Younis L, Stocke K, Wiens RD, Chaitman BR: Application of computerized exercise ECG digitization: Interpretation in large clinical trials. J Electrocardiol 1992;25:101-110
-
(1992)
J Electrocardiol
, vol.25
, pp. 101-110
-
-
Caralis, D.G.1
Shaw, L.2
Bilgere, B.3
Younis, L.4
Stocke, K.5
Wiens, R.D.6
Chaitman, B.R.7
-
23
-
-
0026527437
-
A comparison of angioplasty with medical therapy in the treatment of single-vessel coronary artery disease
-
Parisi AF, Folland ED, Hartigan P: A comparison of angioplasty with medical therapy in the treatment of single-vessel coronary artery disease. N Engl J Med 1992;326:10-16
-
(1992)
N Engl J Med
, vol.326
, pp. 10-16
-
-
Parisi, A.F.1
Folland, E.D.2
Hartigan, P.3
-
24
-
-
0024268952
-
Survey of computer-assisted electrocardiography in the United States
-
Drazen E, Mann N, Borun R, Laks M, Bersen A: Survey of computer-assisted electrocardiography in the United States. J Electrocardiol 1988;21(suppl):S98-S104
-
(1988)
J Electrocardiol
, vol.21
, Issue.SUPPL.
-
-
Drazen, E.1
Mann, N.2
Borun, R.3
Laks, M.4
Bersen, A.5
-
25
-
-
0023231249
-
Computer-assisted versus unassisted analysis of the exercise electrocardiogram in patients without myocardial infarction
-
Detrano R, Salcedo E, Leatherman J, Day K: Computer-assisted versus unassisted analysis of the exercise electrocardiogram in patients without myocardial infarction. J Am Coll Cardiol 1987;10:794-799
-
(1987)
J Am Coll Cardiol
, vol.10
, pp. 794-799
-
-
Detrano, R.1
Salcedo, E.2
Leatherman, J.3
Day, K.4
-
26
-
-
0025338534
-
Comparison of ST segment/heart rate index to standard ST criteria for analysis of exercise electrocardiogram
-
Lachterman B, Lehmann KG, Detrano R, Neutel J, Froelicher VF: Comparison of ST segment/heart rate index to standard ST criteria for analysis of exercise electrocardiogram. Circulation 1990;82:44-50
-
(1990)
Circulation
, vol.82
, pp. 44-50
-
-
Lachterman, B.1
Lehmann, K.G.2
Detrano, R.3
Neutel, J.4
Froelicher, V.F.5
-
27
-
-
84948012343
-
Automated and nomographic analysis of exercise tests
-
Sketch MH, Mohiuddin SM, Nair CK, Mooss AN, Runco V: Automated and nomographic analysis of exercise tests. J Am Med Assoc 1980;243:1052-1055
-
(1980)
J Am Med Assoc
, vol.243
, pp. 1052-1055
-
-
Sketch, M.H.1
Mohiuddin, S.M.2
Nair, C.K.3
Mooss, A.N.4
Runco, V.5
-
28
-
-
0023485866
-
Description and evaluation of a method for computer analysis of the exercise electrocardiogram
-
Rossi L, Carbonieri E, Castello C, Rossi R, Sciarretta G, Eng D, Zardini P: Description and evaluation of a method for computer analysis of the exercise electrocardiogram. J Electrocardiol 1987;20:312-320
-
(1987)
J Electrocardiol
, vol.20
, pp. 312-320
-
-
Rossi, L.1
Carbonieri, E.2
Castello, C.3
Rossi, R.4
Sciarretta, G.5
Eng, D.6
Zardini, P.7
-
29
-
-
0017142657
-
Editorial-whither the ST segment during exercise?
-
Redwood DR, Borer JS, Epstein SE: Editorial-whither the ST segment during exercise? Circulation 1976;545:703-706
-
(1976)
Circulation
, vol.545
, pp. 703-706
-
-
Redwood, D.R.1
Borer, J.S.2
Epstein, S.E.3
-
30
-
-
0026045121
-
The prognostic value of exercise capacity: A review of the literature
-
Morris CK, Ueshima K, Kawaguchi T, Hideg A, Froelicher VF: The prognostic value of exercise capacity: A review of the literature. Am Heart J 1991;122:1423-1431
-
(1991)
Am Heart J
, vol.122
, pp. 1423-1431
-
-
Morris, C.K.1
Ueshima, K.2
Kawaguchi, T.3
Hideg, A.4
Froelicher, V.F.5
|