메뉴 건너뛰기




Volumn 39, Issue 3, 1997, Pages 355-361

Evaluation of Innofluor fluorescence polarization immunoassay kits for the determination of serum concentrations of gentamicin, tobramycin, amikacin and vancomycin

Author keywords

[No Author keywords available]

Indexed keywords

AMIKACIN; ANTIBIOTIC AGENT; GENTAMICIN; TOBRAMYCIN; VANCOMYCIN;

EID: 0030901031     PISSN: 03057453     EISSN: None     Source Type: Journal    
DOI: 10.1093/jac/39.3.355     Document Type: Article
Times cited : (19)

References (9)
  • 2
    • 0027376896 scopus 로고
    • Cost of gentamicin assays carried out by microbiology laboratories
    • Vacani, P. F., Malek, M. M. & Davey, P. G. (1993). Cost of gentamicin assays carried out by microbiology laboratories. Journal of Clinical Pathology 46, 890-5.
    • (1993) Journal of Clinical Pathology , vol.46 , pp. 890-895
    • Vacani, P.F.1    Malek, M.M.2    Davey, P.G.3
  • 4
    • 0021229890 scopus 로고
    • Clinical evaluation of the Abbott TDx fluorescence polarization immunoassay analyzer
    • Oeltgen, P. R., Shank, W. A., Blouin, R. A. & Clark, T. (1984). Clinical evaluation of the Abbott TDx fluorescence polarization immunoassay analyzer. Therapeutic Drug Monitoring 6, 360-7.
    • (1984) Therapeutic Drug Monitoring , vol.6 , pp. 360-367
    • Oeltgen, P.R.1    Shank, W.A.2    Blouin, R.A.3    Clark, T.4
  • 5
    • 0021172275 scopus 로고
    • Laboratory evaluation of five assay methods for vancomycin: Bioassay, high-pressure liquid chromatography, fluorescence polarization immunoassay, radioimmunoassay, and fluorescence immunoassay
    • Pfaller, M. A., Krogstad, D. J., Granich, G. G. & Murray, P. R. (1984). Laboratory evaluation of five assay methods for vancomycin: bioassay, high-pressure liquid chromatography, fluorescence polarization immunoassay, radioimmunoassay, and fluorescence immunoassay. Journal of Clinical Microbiology 20, 311-6.
    • (1984) Journal of Clinical Microbiology , vol.20 , pp. 311-316
    • Pfaller, M.A.1    Krogstad, D.J.2    Granich, G.G.3    Murray, P.R.4
  • 6
    • 0020551096 scopus 로고
    • Automated fluorescence polarization immunoassay for monitoring vancomycin
    • Schwenzer, K. S., Wang, C. H. & Anhalt, J. P. (1983). Automated fluorescence polarization immunoassay for monitoring vancomycin. Therapeutic Drug Monitoring, 5, 341-5.
    • (1983) Therapeutic Drug Monitoring , vol.5 , pp. 341-345
    • Schwenzer, K.S.1    Wang, C.H.2    Anhalt, J.P.3
  • 7
    • 0024408705 scopus 로고
    • Long-term accuracy of fluorescence polarization immunoassays for gentamicin, tobramycin, netilmicin and vancomycin
    • Joos, B., Luthy, R. & Blaser, J. (1989). Long-term accuracy of fluorescence polarization immunoassays for gentamicin, tobramycin, netilmicin and vancomycin. Journal of Antimicrobial Chemotherapy 24, 797-803.
    • (1989) Journal of Antimicrobial Chemotherapy , vol.24 , pp. 797-803
    • Joos, B.1    Luthy, R.2    Blaser, J.3
  • 8
    • 0020684908 scopus 로고
    • Variations in gentamicin C1, C1a, C2, and C2a content of some preparations of gentamicin sulphate used clinically as determined by high-performance liquid chromatography
    • White, L. O., Lovering, A. M. & Reeves, D. S. (1983). Variations in gentamicin C1, C1a, C2, and C2a content of some preparations of gentamicin sulphate used clinically as determined by high-performance liquid chromatography. Therapeutic Drug Monitoring 5, 123-6.
    • (1983) Therapeutic Drug Monitoring , vol.5 , pp. 123-126
    • White, L.O.1    Lovering, A.M.2    Reeves, D.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.