메뉴 건너뛰기




Volumn 15, Issue 7, 1997, Pages 863-867

Convergent flow phenomenon mimics the appearance of venous thrombosis in gradient-echo images with or without the presence of a contrast agent

Author keywords

Complex flow; Convergent flow; Image artifact; Magnetic resonance imaging; Spin dephasing

Indexed keywords

AGED; ARTICLE; CASE REPORT; CLINICAL FEATURE; DOPPLER FLOWMETRY; HUMAN; IMAGE ANALYSIS; IMAGE ENHANCEMENT; INFERIOR CAVA VEIN; KIDNEY BLOOD FLOW; KIDNEY VEIN; LEG EDEMA; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; VEIN THROMBOSIS;

EID: 0030884516     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0730-725X(97)00025-8     Document Type: Article
Times cited : (5)

References (22)
  • 1
    • 0000653425 scopus 로고
    • Flow phenomena
    • D.D. Stark, W.G. Bradley (Eds). St. Louis, MO: Mosby
    • 1. Bradley, W.G. Flow phenomena. In: D.D. Stark, W.G. Bradley (Eds). Magnetic Resonance Imaging, 2nd ed., Vol. 1. St. Louis, MO: Mosby, 1992: pp. 253-298.
    • (1992) Magnetic Resonance Imaging, 2nd Ed. , vol.1 , pp. 253-298
    • Bradley, W.G.1
  • 2
    • 0021972302 scopus 로고
    • Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method
    • 2. Moran, P.R.; Moran, R.A.; Karstaedt, N. Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method. Radiology 154:433-441; 1985.
    • (1985) Radiology , vol.154 , pp. 433-441
    • Moran, P.R.1    Moran, R.A.2    Karstaedt, N.3
  • 3
    • 0024509769 scopus 로고
    • Quantification of blood flow with dynamic MR imaging and presaturation bolus tracking
    • 3. Edelman, R.R.; Mattle, H.P.; Kleefield, J.; Silver, M.S. Quantification of blood flow with dynamic MR imaging and presaturation bolus tracking. Radiology 171:551-556; 1989.
    • (1989) Radiology , vol.171 , pp. 551-556
    • Edelman, R.R.1    Mattle, H.P.2    Kleefield, J.3    Silver, M.S.4
  • 4
    • 0021741851 scopus 로고
    • Blood flow effects in magnetic resonance imaging
    • 4. Axel, L. Blood flow effects in magnetic resonance imaging. Am. J. Roentgenol. 143:1157-1166; 1984.
    • (1984) Am. J. Roentgenol. , vol.143 , pp. 1157-1166
    • Axel, L.1
  • 5
    • 0022367617 scopus 로고
    • Blood flow imaging with MR: Spin-phase phenomena
    • 5. von Schulthess, G.K.; Higgins, C.B. Blood flow imaging with MR: spin-phase phenomena. Radiology 157:687-695; 1985.
    • (1985) Radiology , vol.157 , pp. 687-695
    • Von Schulthess, G.K.1    Higgins, C.B.2
  • 6
    • 0021175090 scopus 로고
    • Pulsatile blood velocity in human arteries displayed by magnetic resonance imaging
    • 6. Feinberg, D.A.; Crooks, L.E.; Hoenninger, J.; Arakawa, M.; Watts, J. Pulsatile blood velocity in human arteries displayed by magnetic resonance imaging. Radiology 153: 177-180; 1984.
    • (1984) Radiology , vol.153 , pp. 177-180
    • Feinberg, D.A.1    Crooks, L.E.2    Hoenninger, J.3    Arakawa, M.4    Watts, J.5
  • 7
    • 0026023195 scopus 로고
    • Appearance of poststenotic jets in MRI: Dependence on flow velocity and on imaging parameters
    • 7. Spielmann, R.P.; Schneider, O.; Thiele, F.; Heller, M.; Buecheler, E. Appearance of poststenotic jets in MRI: Dependence on flow velocity and on imaging parameters. Magn. Reson. Imaging 9:67-72; 1991.
    • (1991) Magn. Reson. Imaging , vol.9 , pp. 67-72
    • Spielmann, R.P.1    Schneider, O.2    Thiele, F.3    Heller, M.4    Buecheler, E.5
  • 8
    • 0022273764 scopus 로고
    • MR imaging of venous and arterial flow by a Selective Saturation-Recovery Spin Echo (SSRSE) method
    • 8. Wehrli, F.W.; Shimakawa, A.; MacFall, J.R.; Axel, L.; Perman, W. MR imaging of venous and arterial flow by a selective saturation-recovery spin echo (SSRSE) method. J. Comput. Assist. Tomogr. 9:537-545; 1985.
    • (1985) J. Comput. Assist. Tomogr. , vol.9 , pp. 537-545
    • Wehrli, F.W.1    Shimakawa, A.2    MacFall, J.R.3    Axel, L.4    Perman, W.5
  • 9
    • 0026601498 scopus 로고
    • Visualization and quantification of the human blood flow by magnetic resonance imaging
    • 9. Boesiger, P.; Maier, S.E.; Kecheng, L.; Scheidegger, M.B.; Meier, D. Visualization and quantification of the human blood flow by magnetic resonance imaging. J. Biomech. 25:55-67; 1992.
    • (1992) J. Biomech. , vol.25 , pp. 55-67
    • Boesiger, P.1    Maier, S.E.2    Kecheng, L.3    Scheidegger, M.B.4    Meier, D.5
  • 10
    • 0011193183 scopus 로고
    • Flow in the macrocirculation: Basic concepts from fluid mechanics
    • E.J. Potchen, J.E. Siebert, E.M. Haacke, A. Gottschalk, (Eds). St. Louis, MO: Mosby
    • 10. Parker, K.H.; Caro, C.G. Flow in the macrocirculation: Basic concepts from fluid mechanics. In: E.J. Potchen, J.E. Siebert, E.M. Haacke, A. Gottschalk, (Eds). Magnetic resonance angiography - concept & applications. St. Louis, MO: Mosby, 1993: pp. 134-145.
    • (1993) Magnetic Resonance Angiography - Concept & Applications , pp. 134-145
    • Parker, K.H.1    Caro, C.G.2
  • 12
    • 0027290691 scopus 로고
    • Mechanisms of signal loss in magnetic resonance imaging of stenoses
    • 12. Gatenby, J.C.; McCauley, T.R.; Gore, J.C. Mechanisms of signal loss in magnetic resonance imaging of stenoses. Med. Phys. 20:1049-1057; 1993.
    • (1993) Med. Phys. , vol.20 , pp. 1049-1057
    • Gatenby, J.C.1    McCauley, T.R.2    Gore, J.C.3
  • 13
    • 0028099916 scopus 로고
    • Pulse sequence design for MR velocity mapping of complex flow: Notes on the necessity of low echo times
    • 13. Stahlberg, F.; Thomsen, C.; Sondergaard, L.; Henriksen, O. Pulse sequence design for MR velocity mapping of complex flow: Notes on the necessity of low echo times. Magn. Reson. Imaging 12:1255-1262; 1994.
    • (1994) Magn. Reson. Imaging , vol.12 , pp. 1255-1262
    • Stahlberg, F.1    Thomsen, C.2    Sondergaard, L.3    Henriksen, O.4
  • 14
    • 0025324799 scopus 로고
    • Improved contrast at 1.5 Tesla using half-Fourier: Application to spin-echo and angiographic imaging
    • 14. Haacke, E.M.; Mitchell, J.; Lee, D. Improved contrast at 1.5 Tesla using half-Fourier: Application to spin-echo and angiographic imaging. Magn. Reson. Imaging 8:79-90; 1990.
    • (1990) Magn. Reson. Imaging , vol.8 , pp. 79-90
    • Haacke, E.M.1    Mitchell, J.2    Lee, D.3
  • 15
    • 0000857167 scopus 로고
    • Optimal imaging strategies for three-dimensional nuclear magnetic resonance microscopy
    • 15. Ahn, C.B.; Chu, W.C. Optimal imaging strategies for three-dimensional nuclear magnetic resonance microscopy. J. Magn. Reson. 94:455-470; 1991.
    • (1991) J. Magn. Reson. , vol.94 , pp. 455-470
    • Ahn, C.B.1    Chu, W.C.2
  • 16
    • 0025890374 scopus 로고
    • NMR angiography with enhanced quasi-half-echo scanning
    • 16. Guo, Q.; Kashmar, G.; Nalcioglu, O. NMR angiography with enhanced quasi-half-echo scanning. Magn. Reson. Imaging 9:129-139; 1991.
    • (1991) Magn. Reson. Imaging , vol.9 , pp. 129-139
    • Guo, Q.1    Kashmar, G.2    Nalcioglu, O.3
  • 17
    • 0025938956 scopus 로고
    • FID-acquired echoes (FAcE): A short echo time imaging method for flow artifact suppression
    • 17. Scheidegger, M.B.; Maier, S.E.; Boesinger, P. FID-acquired echoes (FAcE): A short echo time imaging method for flow artifact suppression. Magn. Reson. Imaging 9:517-524; 1991.
    • (1991) Magn. Reson. Imaging , vol.9 , pp. 517-524
    • Scheidegger, M.B.1    Maier, S.E.2    Boesinger, P.3
  • 18
    • 0025886983 scopus 로고
    • MR imaging of the portal venous system: Value of gradient echo imaging as an adjunct to spin echo imaging
    • 18. Silverman, P.M.; Patt, R.H.; Garra, B.S.; Horii, S.C.; Cooper, C.; Hayes, W.S.; Zeman, R.K. MR imaging of the portal venous system: Value of gradient echo imaging as an adjunct to spin echo imaging. Am. J. Roentgenol. 157: 297-302; 1991.
    • (1991) Am. J. Roentgenol. , vol.157 , pp. 297-302
    • Silverman, P.M.1    Patt, R.H.2    Garra, B.S.3    Horii, S.C.4    Cooper, C.5    Hayes, W.S.6    Zeman, R.K.7
  • 22
    • 0023270454 scopus 로고
    • Disappearing iliac vessels: An MR phase cancellation phenomenon
    • 22. Mayo, J.; McVeigh, E.R.; Hoffman N.; Poon, P.Y.; Henkelman R.M. Disappearing iliac vessels: An MR phase cancellation phenomenon. Radiology 164:555-557; 1986.
    • (1986) Radiology , vol.164 , pp. 555-557
    • Mayo, J.1    McVeigh, E.R.2    Hoffman, N.3    Poon, P.Y.4    Henkelman, R.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.