메뉴 건너뛰기




Volumn 10, Issue 1, 1997, Pages 41-47

Sonographic prediction of malignancy in adnexal masses using multivariate logistic regression analysis

Author keywords

Doppler ultrasound; Logistic regression analysis; Ovarian cancer; Transvaginal ultrasound

Indexed keywords

ADNEXA DISEASE; ADULT; AGED; ARTICLE; B SCAN; COLOR ULTRASOUND FLOWMETRY; FEMALE; HISTOLOGY; HUMAN; MAJOR CLINICAL STUDY; MALIGNANT NEOPLASTIC DISEASE; MULTIVARIATE ANALYSIS; ONSET AGE; OVARY TUMOR; PELVIS; PREDICTION; PRIORITY JOURNAL; PROBABILITY; REGRESSION ANALYSIS; STATISTICAL MODEL; TRANSVAGINAL ECHOGRAPHY; TUMOR DIFFERENTIATION; TUMOR VOLUME; ULTRASOUND;

EID: 0030882279     PISSN: 09607692     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1469-0705.1997.10010041.x     Document Type: Article
Times cited : (126)

References (24)
  • 1
    • 0024306230 scopus 로고
    • Transvaginal colour flow imaging: A possible new screening technique for ovarian cancer
    • Bourne, T. H., Campbell, S., Steer, C., Whitehead, M. I. and Collins, W. P. (1989). Transvaginal colour flow imaging: a possible new screening technique for ovarian cancer. Br. Med. J., 299, 1367-70
    • (1989) Br. Med. J. , vol.299 , pp. 1367-1370
    • Bourne, T.H.1    Campbell, S.2    Steer, C.3    Whitehead, M.I.4    Collins, W.P.5
  • 2
    • 0025904410 scopus 로고
    • Evaluation of adnexal masses with transvaginal color ultrasound
    • Kurjak, A., Zalud, I. and Alfirevic, Z. (1991). Evaluation of adnexal masses with transvaginal color ultrasound. J. Ultra~sound Med., 10, 295-7
    • (1991) J. Ultrasound Med. , vol.10 , pp. 295-297
    • Kurjak, A.1    Zalud, I.2    Alfirevic, Z.3
  • 3
    • 0027479210 scopus 로고
    • Transvaginal ultrasonographic characterization of ovarian masses by means of color flow-directed Doppler measurements and a morphologic scoring system
    • Timor-Tritsch, I. E., Lerner, J. P., Monteagudo, A. and Santos, R. (1993). Transvaginal ultrasonographic characterization of ovarian masses by means of color flow-directed Doppler measurements and a morphologic scoring system. Am. J. Obstet. Gynecol., 168, 909-13
    • (1993) Am. J. Obstet. Gynecol. , vol.168 , pp. 909-913
    • Timor-Tritsch, I.E.1    Lerner, J.P.2    Monteagudo, A.3    Santos, R.4
  • 4
    • 84989094213 scopus 로고
    • Validity of pulsatility and resistance indices in classification of adnexal tumors with transvaginal color Doppler ultrasound
    • Tekay, A. and Jouppila, P. (1992). Validity of pulsatility and resistance indices in classification of adnexal tumors with transvaginal color Doppler ultrasound. Ultrasound Obstet. Gynecol., 2, 338-44
    • (1992) Ultrasound Obstet. Gynecol. , vol.2 , pp. 338-344
    • Tekay, A.1    Jouppila, P.2
  • 5
    • 0027449333 scopus 로고
    • Conventional and color Doppler transvaginal sonography of pelvic masses: A comparison of relative histologic specificities
    • Fleischer, A. C., Cullinan, J. A., Kepple, D. M. and Williams, L. L. (1993). Conventional and color Doppler transvaginal sonography of pelvic masses: a comparison of relative histologic specificities. J. Ultrasound Med., 12, 705-12
    • (1993) J. Ultrasound Med. , vol.12 , pp. 705-712
    • Fleischer, A.C.1    Cullinan, J.A.2    Kepple, D.M.3    Williams, L.L.4
  • 6
    • 0028176033 scopus 로고
    • Limited contribution of Doppler velocimetry to the differential diagnosis of extrauterine pelvic tumours
    • Valentin, L., Sladkevicius, P. and Marsal, K. (1994). Limited contribution of Doppler velocimetry to the differential diagnosis of extrauterine pelvic tumours. Obstet. Gynecol., 83, 425-33
    • (1994) Obstet. Gynecol. , vol.83 , pp. 425-433
    • Valentin, L.1    Sladkevicius, P.2    Marsal, K.3
  • 7
    • 0028013539 scopus 로고
    • Flow characteristics in benign and malignant gynecologic tumors using transvaginal color flow Doppler
    • Carter, J., Saltzman, A., Hartenbach, E., Fowler, J., Carson, L. and Twiggs, L. B. (1994). Flow characteristics in benign and malignant gynecologic tumors using transvaginal color flow Doppler. Obstet. Gynecol., 83, 125-30
    • (1994) Obstet. Gynecol. , vol.83 , pp. 125-130
    • Carter, J.1    Saltzman, A.2    Hartenbach, E.3    Fowler, J.4    Carson, L.5    Twiggs, L.B.6
  • 8
    • 0028895817 scopus 로고
    • Differentiation of benign and malignant adnexal masses: Relative value of gray-scale, color Doppler, and spectral Doppler sonography
    • Stein, S. M., Leifer-Narin, S., Johnson, M. B., Roman, L. D., Muderspach, L. I., Tyszka, J. M. and Ralls, P. W. (1995). Differentiation of benign and malignant adnexal masses: relative value of gray-scale, color Doppler, and spectral Doppler sonography. Am. J. Roentgenol., 164, 381-6
    • (1995) Am. J. Roentgenol. , vol.164 , pp. 381-386
    • Stein, S.M.1    Leifer-Narin, S.2    Johnson, M.B.3    Roman, L.D.4    Muderspach, L.I.5    Tyszka, J.M.6    Ralls, P.W.7
  • 9
    • 0029764621 scopus 로고    scopus 로고
    • A comparison of intratumoural indices of blood flow velocity and impedance for the diagnosis of ovarian cancer
    • Tailor, A., Jurkovic, D., Bourne, T. H., Natucci, M., Collins, W. P. and Campbell, S. (1996). A comparison of intratumoural indices of blood flow velocity and impedance for the diagnosis of ovarian cancer. Ultrasound Med. Biol., 22, 837-43
    • (1996) Ultrasound Med. Biol. , vol.22 , pp. 837-843
    • Tailor, A.1    Jurkovic, D.2    Bourne, T.H.3    Natucci, M.4    Collins, W.P.5    Campbell, S.6
  • 10
    • 0002923202 scopus 로고
    • Prediction analyses for binary data
    • Miller, R. G., Efron, B., Brown, B. W. J. and Moses, L. E. (eds.) New York: John Wiley & Sons
    • Brown, B. W. J. (1980). Prediction analyses for binary data. In Miller, R. G., Efron, B., Brown, B. W. J. and Moses, L. E. (eds.) Biostatistics Casebook, pp.3-18. (New York: John Wiley & Sons)
    • (1980) Biostatistics Casebook , pp. 3-18
    • Brown, B.W.J.1
  • 11
    • 0029845122 scopus 로고    scopus 로고
    • Using a logistic model to identify women with first-trimester spontaneous abortion suitable for expectant management
    • Nielsen, S., Hahlin, M. and Oden, A. (1996). Using a logistic model to identify women with first-trimester spontaneous abortion suitable for expectant management. Br. J. Obstet. Gynaecol., 103, 1230-5
    • (1996) Br. J. Obstet. Gynaecol. , vol.103 , pp. 1230-1235
    • Nielsen, S.1    Hahlin, M.2    Oden, A.3
  • 12
    • 0002542619 scopus 로고
    • Ultrasonic angiology
    • Harens, A. W. and Adamson, L. (eds.) Edinburgh: Churchill Livingstone
    • Gosling, R. G. and King, D. H. (1975). Ultrasonic angiology. In Harens, A. W. and Adamson, L. (eds.) Arteries and Veins, pp. 61-98. (Edinburgh: Churchill Livingstone)
    • (1975) Arteries and Veins , pp. 61-98
    • Gosling, R.G.1    King, D.H.2
  • 13
    • 0016180551 scopus 로고
    • Applications clinique de l'examen Doppler transcutane
    • Peronneau, P. (ed.) Paris: Inserm
    • Pourcelot, L. (1974). Applications clinique de l'examen Doppler transcutane. In Peronneau, P. (ed.) Velocimetric Ultrasonore Doppler, pp. 213-40. (Paris: Inserm)
    • (1974) Velocimetric Ultrasonore Doppler , pp. 213-240
    • Pourcelot, L.1
  • 14
    • 84989040366 scopus 로고
    • Quantitative flow measurement for classification of ovarian tumors by transvaginal color Doppler sonography in postmenopausal patients
    • Prompeler, H. J., Madjar, H., Sauerbrei, W., Lattermann, U. and Pfleiderer, A. (1994). Quantitative flow measurement for classification of ovarian tumors by transvaginal color Doppler sonography in postmenopausal patients. Ultrasound Obstet. Gynecol., 4, 406-13
    • (1994) Ultrasound Obstet. Gynecol. , vol.4 , pp. 406-413
    • Prompeler, H.J.1    Madjar, H.2    Sauerbrei, W.3    Lattermann, U.4    Pfleiderer, A.5
  • 15
    • 0028999310 scopus 로고
    • Intratumoral peak systolic velocity as a new possible predictor for detection of adnexal malignancy
    • Hata, K., Hata, T. and Kitao, M. (1995). Intratumoral peak systolic velocity as a new possible predictor for detection of adnexal malignancy. Am. J. Obstet. Gynecol., 172, 1496-500
    • (1995) Am. J. Obstet. Gynecol. , vol.172 , pp. 1496-1500
    • Hata, K.1    Hata, T.2    Kitao, M.3
  • 16
    • 0029349033 scopus 로고
    • Interobserver agreement in the results of Doppler examinations of extrauterine pelvic tumours
    • Sladkevicius, P. and Valentin, L. (1995). Interobserver agreement in the results of Doppler examinations of extrauterine pelvic tumours. Ultrasound Obstet. Gynecol., 6, 91-6
    • (1995) Ultrasound Obstet. Gynecol. , vol.6 , pp. 91-96
    • Sladkevicius, P.1    Valentin, L.2
  • 18
    • 0024711621 scopus 로고
    • Revised FIGO staging for gynaecological cancer
    • Shepherd, J. H. (1988). Revised FIGO staging for gynaecological cancer. Br. J. Obstet. Gynaecol., 96, 889-92
    • (1988) Br. J. Obstet. Gynaecol. , vol.96 , pp. 889-892
    • Shepherd, J.H.1
  • 19
    • 0029008314 scopus 로고
    • Software for illustrative presentation of basic clinical characteristics of laboratory tests - GraphROC for Windows
    • Kairisto, V. and Poola, A. (1995). Software for illustrative presentation of basic clinical characteristics of laboratory tests - GraphROC for Windows. Scand. J. Clin. Lab. Invest., 55(Suppl. 222), 43-60
    • (1995) Scand. J. Clin. Lab. Invest. , vol.55 , Issue.222 SUPPL. , pp. 43-60
    • Kairisto, V.1    Poola, A.2
  • 20
    • 0020524559 scopus 로고
    • A method of comparing the areas under the receiver operating characteristics curves derived from the same cases
    • Hanley, J. A. and McNeil, B. (1983). A method of comparing the areas under the receiver operating characteristics curves derived from the same cases. Radiology, 148, 839-43
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.2
  • 22
    • 0025865303 scopus 로고
    • Transvaginal sonographic characterization of ovarian disease: Evaluation of a new scoring system to predict ovarian malignancy
    • Sassone, A. M., Timor-Tritsch, I. E., Artner, A., Westhoff, C. and Warren, W. B. (1991). Transvaginal sonographic characterization of ovarian disease: evaluation of a new scoring system to predict ovarian malignancy. Obstet. Gynecol., 78, 70-6
    • (1991) Obstet. Gynecol. , vol.78 , pp. 70-76
    • Sassone, A.M.1    Timor-Tritsch, I.E.2    Artner, A.3    Westhoff, C.4    Warren, W.B.5
  • 23
    • 0028197105 scopus 로고
    • Transvaginal ultrasonographic characterization of ovarian masses with an improved, weighted scoring system
    • Lerner, J. P., Timor-Tritsch, I. E., Federman, A. and Abramovich, G. (1994). Transvaginal ultrasonographic characterization of ovarian masses with an improved, weighted scoring system. Am. J. Obstet. Gynecol., 170, 81-5
    • (1994) Am. J. Obstet. Gynecol. , vol.170 , pp. 81-85
    • Lerner, J.P.1    Timor-Tritsch, I.E.2    Federman, A.3    Abramovich, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.