Volumn 52, Issue 7, 1997, Pages 662-667

Reshaping the Macintosh blade using biomechanical modelling. A prospective comparative study in patients

Author keywords

Anaesthetic techniques; laryngoscopy; Equipment; laryngoscopes; Intubation, tracheal; technique; Larynx; laryngoscopy

Indexed keywords

ADULT; AGED; ANESTHETIC EQUIPMENT; ARTICLE; BIOMECHANICS; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; ENDOTRACHEAL INTUBATION; FEMALE; FORCE; HUMAN; INCISOR; LARYNGOSCOPY; MALE; MAXILLA;

EID: 0030879481     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2044.1997.134-az0133.x     Document Type: Article
Times cited : (22)

References (14)
  • 2
    • 0024600122 scopus 로고
    • Laryngoscope design and the difficult adult tracheal intubation
    • McIntyre JWR. Laryngoscope design and the difficult adult tracheal intubation. Canadian Journal of Anaesthesia 1989; 36: 94-8.
    • (1989) Canadian Journal of Anaesthesia , vol.36 , pp. 94-98
    • McIntyre, J.W.R.1
  • 3
    • 0028566560 scopus 로고
    • Forces acting on maxillary incisor teeth during laryngoscopy using the Macintosh laryngoscope
    • Bucx MJL, Snijders CJ, van Geel RTM, et al. Forces acting on maxillary incisor teeth during laryngoscopy using the Macintosh laryngoscope. Anaesthesia 1994; 49: 1064-70.
    • (1994) Anaesthesia , vol.49 , pp. 1064-1070
    • Bucx, M.J.L.1    Snijders, C.J.2    Van Geel, R.T.M.3
  • 7
    • 0000270555 scopus 로고
    • A new laryngoscope
    • Macintosh RR. A new laryngoscope. The Lancet 1943; 1: 205.
    • (1943) The Lancet , vol.1 , pp. 205
    • Macintosh, R.R.1
  • 8
    • 0027159550 scopus 로고
    • An analysis of laryngoscope blade shape and design: New criteria for laryngoscope evaluation
    • Marks RRD, Hancock R, Charters P. An analysis of laryngoscope blade shape and design: new criteria for laryngoscope evaluation. Canadian Journal of Anaesthesia 1993; 40: 262-70.
    • (1993) Canadian Journal of Anaesthesia , vol.40 , pp. 262-270
    • Marks, R.R.D.1    Hancock, R.2    Charters, P.3
  • 10
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11.
    • (1984) Anaesthesia , vol.39 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 11
    • 0000362559 scopus 로고
    • Improved laryngoscope blade designed for ease of manipulation and reduction of trauma
    • Bizzarri DV, Giuffrida JG. Improved laryngoscope blade designed for ease of manipulation and reduction of trauma. Anesthesia and Analgesia (Current Researches) 1958; 37: 231-2.
    • (1958) Anesthesia and Analgesia (Current Researches) , vol.37 , pp. 231-232
    • Bizzarri, D.V.1    Giuffrida, J.G.2
  • 12
    • 0025095472 scopus 로고
    • The adult cervical spine: Implications for airway management
    • Crosby ET. The adult cervical spine: implications for airway management. Canadian Journal of Anaesthesia 1990; 37: 77-93.
    • (1990) Canadian Journal of Anaesthesia , vol.37 , pp. 77-93
    • Crosby, E.T.1
  • 13
    • 0026017726 scopus 로고
    • Unexpected, difficult laryngoscopy: A prospective survey in routine general surgery
    • Williams KN, Carli F, Cormack RS. Unexpected, difficult laryngoscopy: a prospective survey in routine general surgery. British Journal of Anaesthesia 1991; 66: 38-44.
    • (1991) British Journal of Anaesthesia , vol.66 , pp. 38-44
    • Williams, K.N.1    Carli, F.2    Cormack, R.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.