메뉴 건너뛰기




Volumn 73, Issue 5, 1997, Pages 787-793

A case study on radon remedial measures in a family dwelling

Author keywords

Computer calculations; Modeling, dose assessment; Radon; Ventilation

Indexed keywords

RADON;

EID: 0030879408     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004032-199711000-00006     Document Type: Article
Times cited : (6)

References (18)
  • 4
    • 0342339146 scopus 로고
    • Watford, UK: Building Research Establishment
    • Building Research Establishment. BREEZE 6.0 User Manual. Watford, UK: Building Research Establishment; 1993.
    • (1993) BREEZE 6.0 User Manual
  • 5
    • 0026984703 scopus 로고
    • The effect of natural ventilation on radon and radon progeny levels in houses
    • Cavallo, A.; Gadsby, K.; Reddy, T. A.; Socolow, R. The effect of natural ventilation on radon and radon progeny levels in houses. Radiat. Prot. Dosim. 45:569-573; 1992a.
    • (1992) Radiat. Prot. Dosim. , vol.45 , pp. 569-573
    • Cavallo, A.1    Gadsby, K.2    Reddy, T.A.3    Socolow, R.4
  • 6
    • 0026909739 scopus 로고
    • Use of natural basement ventilation to control radon in single family dwellings
    • Cavallo. A.; Gadsby, K.; Reddy, T. A. Use of natural basement ventilation to control radon in single family dwellings. Atmospheric Environ. 26:2251-2256; 1992b.
    • (1992) Atmospheric Environ. , vol.26 , pp. 2251-2256
    • Cavallo, A.1    Gadsby, K.2    Reddy, T.A.3
  • 10
    • 0027004991 scopus 로고
    • Models of radon entry
    • Gadgil, A. J. Models of radon entry. Radiat. Prot. Dosim. 45:373-379; 1992.
    • (1992) Radiat. Prot. Dosim. , vol.45 , pp. 373-379
    • Gadgil, A.J.1
  • 11
    • 0028344881 scopus 로고
    • Influence of ventilation strategies on indoor radon concentrations based on a semiempirical model for Florida-style houses
    • Hintenlang, D E.; Alahmady, K. K. Influence of ventilation strategies on indoor radon concentrations based on a semiempirical model for Florida-style houses. Health Phys. 66:427-432; 1994.
    • (1994) Health Phys. , vol.66 , pp. 427-432
    • Hintenlang, D.E.1    Alahmady, K.K.2
  • 14
    • 0002465296 scopus 로고
    • Preventing radon entry
    • Nazaroff, W. W.; Nero, A. V., eds. New York: John Wiley & Sons
    • Scott, A. G. Preventing radon entry. In: Nazaroff, W. W.; Nero, A. V., eds. Radon and its decay products in indoor air. New York: John Wiley & Sons; 1988: 407-433.
    • (1988) Radon and Its Decay Products in Indoor Air , pp. 407-433
    • Scott, A.G.1
  • 18
    • 0005451964 scopus 로고
    • Reducing indoor radon levels in a UK test house using different ventilation strategies
    • Nashville, TN: American Association of Radon Scientist and Technologists Inc.
    • Welsh, P. A. Reducing indoor radon levels in a UK test house using different ventilation strategies. The Proceedings of '95 International Radon Symposium. Nashville, TN: American Association of Radon Scientist and Technologists Inc.; 1995.
    • (1995) The Proceedings of '95 International Radon Symposium
    • Welsh, P.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.