Volumn 96, Issue 6, 1997, Pages 2016-2021

Guidance of radiofrequency endocardial ablation with real-time three- dimensional magnetic navigation system

Author keywords

Arrhythmia; Catheter ablation; Electrophysiology; Mapping

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; AUTOPSY; CATHETER ABLATION; CONTROLLED STUDY; ENDOCARDIUM; FLUOROSCOPY; HEART ATRIUM ARRHYTHMIA; HEART RIGHT ATRIUM; MAGNETIC FIELD; MALE; NONHUMAN; PRIORITY JOURNAL; REPRODUCIBILITY; SWINE; THREE DIMENSIONAL IMAGING;

EID: 0030874863     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.96.6.2016     Document Type: Article
Times cited : (156)

References (20)
  • 2
    • 0028092959 scopus 로고
    • Radiofrequency catheter ablation in unusual mechanisms of atrial fibrillation: Report of three cases
    • Haïssaguerre M, Marcus FI, Fischer B, Clementy J. Radiofrequency catheter ablation in unusual mechanisms of atrial fibrillation: report of three cases. J Cardiovasc Electrophysiol. 1994;5: 743-751.
    • (1994) J Cardiovasc Electrophysiol , vol.5 , pp. 743-751
    • Haïssaguerre, M.1    Marcus, F.I.2    Fischer, B.3    Clementy, J.4
  • 3
    • 0029082028 scopus 로고
    • Radiofrequency ablation: What is left?
    • Zipes DP. Radiofrequency ablation: what is left? Eur Heart J. 1995;16(suppl G):24-27.
    • (1995) Eur Heart J , vol.16 , Issue.SUPPL. G , pp. 24-27
    • Zipes, D.P.1
  • 4
    • 0003302270 scopus 로고
    • The biophysics and pathophysiology of lesion formation during radiofrequency catheter ablation
    • Zipes DP, Jalife J, eds. Philadelphia, Pa: WB Saunders
    • Haines DE. The biophysics and pathophysiology of lesion formation during radiofrequency catheter ablation. In: Zipes DP, Jalife J, eds. Cardiac Electrophysiology: From Cell to Bedside. Philadelphia, Pa: WB Saunders; 1995:1442-1452.
    • (1995) Cardiac Electrophysiology: From Cell to Bedside , pp. 1442-1452
    • Haines, D.E.1
  • 5
    • 0028881908 scopus 로고
    • Catheter ablation for the treatment of paroxysmal supraventricular tachycardia
    • Naccarelli GV, Shih H, Jalal S. Catheter ablation for the treatment of paroxysmal supraventricular tachycardia. J Cardiovasc Electrophysiol. 1995;6(10 pt 2):951-961.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , Issue.10 PART 2 , pp. 951-961
    • Naccarelli, G.V.1    Shih, H.2    Jalal, S.3
  • 6
    • 0342632854 scopus 로고
    • NASPE survey on catheter ablation
    • Scheinman MM. NASPE survey on catheter ablation. Pacing Clin Electrophysiol. 1995;18:1474-1478.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 1474-1478
    • Scheinman, M.M.1
  • 7
    • 0029998815 scopus 로고    scopus 로고
    • The present role of radiofrequency catheter ablation in the management of cardiac arrhythmias
    • Kay GN, Plumb VJ. The present role of radiofrequency catheter ablation in the management of cardiac arrhythmias. Am J Med. 1996;100:344-356.
    • (1996) Am J Med , vol.100 , pp. 344-356
    • Kay, G.N.1    Plumb, V.J.2
  • 12
    • 0028911685 scopus 로고
    • Radiofrequency catheter ablation of the atria reduces inducibility and duration of atrial fibrillation in dogs
    • Elvan A, Pride HP, Eble JN, Zipes DP. Radiofrequency catheter ablation of the atria reduces inducibility and duration of atrial fibrillation in dogs. Circulation. 1995;91:2235-2244.
    • (1995) Circulation , vol.91 , pp. 2235-2244
    • Elvan, A.1    Pride, H.P.2    Eble, J.N.3    Zipes, D.P.4
  • 13
    • 0005656456 scopus 로고    scopus 로고
    • Accuracy of the in vivo determination of location using a new nonfluoroscopic electroanatomical mapping system
    • Abstract
    • Hayam G, Gepstein L, Ben-Haim SA. Accuracy of the in vivo determination of location using a new nonfluoroscopic electroanatomical mapping system. Pacing Clin Electrophysiol. 1996;19(4 pt 2):712. Abstract.
    • (1996) Pacing Clin Electrophysiol , vol.19 , Issue.4 PART 2 , pp. 712
    • Hayam, G.1    Gepstein, L.2    Ben-Haim, S.A.3
  • 15
    • 0005758496 scopus 로고    scopus 로고
    • A new method for cardiac volumetric measurement based on nonfluoroscopic electroanatomical mapping of the heart
    • Abstract
    • Gepstein L, Hayam G, Josephson ME, Ben-Haim SA. A new method for cardiac volumetric measurement based on nonfluoroscopic electroanatomical mapping of the heart. Pacing Clin Electrophysiol. 1996;19(4 pt 2):724. Abstract.
    • (1996) Pacing Clin Electrophysiol , vol.19 , Issue.4 PART 2 , pp. 724
    • Gepstein, L.1    Hayam, G.2    Josephson, M.E.3    Ben-Haim, S.A.4
  • 17
    • 0029074563 scopus 로고
    • Temperature measurement as a determinant of tissue heating during radiofrequency catheter ablation: An examination of electrode thermistor positioning for measurement accuracy
    • McRury ID, Whayne JG, Haines DE. Temperature measurement as a determinant of tissue heating during radiofrequency catheter ablation: an examination of electrode thermistor positioning for measurement accuracy. J Cardiovasc Electrophysiol. 1995;6:268-278.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 268-278
    • McRury, I.D.1    Whayne, J.G.2    Haines, D.E.3
  • 20
    • 0030055768 scopus 로고    scopus 로고
    • Non-pharmacological treatment of supraventricular arrhythmias
    • Josephson ME, Schibgilla VH. Non-pharmacological treatment of supraventricular arrhythmias. Eur Heart J. 1996;17(suppl C):26-34.
    • (1996) Eur Heart J , vol.17 , Issue.SUPPL. C , pp. 26-34
    • Josephson, M.E.1    Schibgilla, V.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.