-
1
-
-
0027070923
-
Pressure recovery in aortic stenosis: An in vitro study in a pulsatile flow model
-
Voelker W, Reul H, Stelzer T, et al. Pressure recovery in aortic stenosis: an in vitro study in a pulsatile flow model. J Am Coll Cardiol. 1992; 20: 1585-93.
-
(1992)
J Am Coll Cardiol.
, vol.20
, pp. 1585-1593
-
-
Voelker, W.1
Reul, H.2
Stelzer, T.3
-
2
-
-
0023792339
-
A review of hydrodynamic principles for the cardiologist: Applications to the study of blood flow and jets by imaging techniques
-
Yoganathan AP, Cape EG, Sung H-W, et al. A review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques. JACC 1988; 12: 1344-45.
-
(1988)
JACC
, vol.12
, pp. 1344-1345
-
-
Yoganathan, A.P.1
Cape, E.G.2
Sung, H.-W.3
-
3
-
-
26844445306
-
-
Berlin, Heidelberg, New York: Springer-Verlag
-
Truekenbrodt E. Stromungsmechanik. Berlin, Heidelberg, New York: Springer-Verlag. 1989: 18; 216-18.
-
(1989)
Stromungsmechanik
, vol.18
, pp. 216-218
-
-
Truekenbrodt, E.1
-
4
-
-
0027399467
-
Effect of stenosis geometry on the doppler-catheter gradient relation in vitro: A manifestation of pressure recovery
-
Baumgartner H, Schima H, Tulzer G, Kuhn P. Effect of stenosis geometry on the doppler-catheter gradient relation in vitro: A manifestation of pressure recovery. J Am Coll Cardiol. 1993; 21: 1018-25.
-
(1993)
J Am Coll Cardiol.
, vol.21
, pp. 1018-1025
-
-
Baumgartner, H.1
Schima, H.2
Tulzer, G.3
Kuhn, P.4
-
5
-
-
0021931764
-
The accuracy of Doppler ultrasound measurement of pressure gradients across irregular, dual, and tunnellike obstructions to blood flow
-
Teirstein PS, Yock PG, Popp RL. The accuracy of Doppler ultrasound measurement of pressure gradients across irregular, dual, and tunnellike obstructions to blood flow. Circulation. 1985; 72: 577-84.
-
(1985)
Circulation
, vol.72
, pp. 577-584
-
-
Teirstein, P.S.1
Yock, P.G.2
Popp, R.L.3
-
6
-
-
0024536693
-
Seminar on in vitro studies of cardiac flow and their applications for clinical doppler echocardiography - III. Pressure recovery distal to a stenosis: Potential cause of gradient "overestimation" by doppler echocardiography
-
Levine RA, Jimoh A, Cape EG, et al. Seminar on in vitro studies of cardiac flow and their applications for clinical doppler echocardiography - III. Pressure recovery distal to a stenosis: Potential cause of gradient "overestimation" by doppler echocardiography. J Am Coll Cardiol. 1989; 13: 706-15.
-
(1989)
J Am Coll Cardiol.
, vol.13
, pp. 706-715
-
-
Levine, R.A.1
Jimoh, A.2
Cape, E.G.3
-
7
-
-
0029825136
-
Importance of pressure recovery for the assessment of aortic stenosis by doppler ultrasound. Role of aortic size, aortic valve area, and direction of the stenotic jet in vitro
-
Niederberger J, Schima H, Maurer G, Baumgartner H. Importance of pressure recovery for the assessment of aortic stenosis by doppler ultrasound. Role of aortic size, aortic valve area, and direction of the stenotic jet in vitro. Circulation. 1996; 94: 1934-40.
-
(1996)
Circulation
, vol.94
, pp. 1934-1940
-
-
Niederberger, J.1
Schima, H.2
Maurer, G.3
Baumgartner, H.4
-
8
-
-
0029845424
-
Turbulent/viscous interactions control Doppler/catheter pressure discrepancies in aortic stenosis. the role of the Reynolds number
-
Cape EG, Jones M, Yamada I, et al. Turbulent/viscous interactions control Doppler/catheter pressure discrepancies in aortic stenosis. The role of the Reynolds number. Circulation. 1996; 94: 2975-81.
-
(1996)
Circulation
, vol.94
, pp. 2975-2981
-
-
Cape, E.G.1
Jones, M.2
Yamada, I.3
-
9
-
-
26844547485
-
Pressure recovery, not maximal orifice pressure drop, influences left ventricular work in aortic stenosis
-
[abstract # 735-5]
-
Russel S, Fontaine AA, Grimes RY, et al. Pressure recovery, not maximal orifice pressure drop, influences left ventricular work in aortic stenosis, [abstract # 735-5] JACC. 1996; 27: 143A.
-
(1996)
JACC
, vol.27
-
-
Russel, S.1
Fontaine, A.A.2
Grimes, R.Y.3
-
10
-
-
0027474615
-
Pressure recovery distal to stenoses: Expanding clinical applications of engineering principles
-
Levine RA, Cape EG, Yoganathan AP. Pressure recovery distal to stenoses: Expanding clinical applications of engineering principles. J Am Coll Cardiol. 1993; 21: 1026-28.
-
(1993)
J Am Coll Cardiol.
, vol.21
, pp. 1026-1028
-
-
Levine, R.A.1
Cape, E.G.2
Yoganathan, A.P.3
-
11
-
-
0027552897
-
Assessment of prosthetic valve hemodynamics by doppler: Lessons from in vitro studies of the St. Jude valve
-
Khan SS. Assessment of prosthetic valve hemodynamics by doppler: Lessons from in vitro studies of the St. Jude valve. J Heart Valve Dis. 1993; 2: 183-93.
-
(1993)
J Heart Valve Dis.
, vol.2
, pp. 183-193
-
-
Khan, S.S.1
-
12
-
-
0025552864
-
Discrepancies between doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery
-
Baumgartner H, Khan S, DeRobertis M, et al. Discrepancies between doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery. Circulation. 1990; 82: 1467-75.
-
(1990)
Circulation
, vol.82
, pp. 1467-1475
-
-
Baumgartner, H.1
Khan, S.2
DeRobertis, M.3
-
13
-
-
0026512411
-
Effect of prosthetic aortic valve design on the doppler-catheter gradient correlation: An in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves
-
Baumgartner H, Khan S, DeRobertis M, et al. Effect of prosthetic aortic valve design on the doppler-catheter gradient correlation: an in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves. J Am Coll Cardiol. 1992; 19: 324-32.
-
(1992)
J Am Coll Cardiol.
, vol.19
, pp. 324-332
-
-
Baumgartner, H.1
Khan, S.2
DeRobertis, M.3
|