메뉴 건너뛰기




Volumn 12, Issue 7, 1997, Pages 577-585

Photosensitive polyurethanes applied to the development of CHEMFET and ENFET devices for biomedical sensing

Author keywords

Biocompatibility; CHEMFET; ENFET; Packaging; Photoc urable membranes; Photolithography; Polyurethane

Indexed keywords

BIOCOMPATIBILITY; CHEMICALLY SENSITIVE FIELD EFFECT TRANSISTORS; ION SENSITIVE FIELD EFFECT TRANSISTORS; PHOTOLITHOGRAPHY; PHOTOSENSITIVITY; POLYURETHANES; SEMICONDUCTOR DEVICE MANUFACTURE;

EID: 0030866115     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(96)00081-4     Document Type: Article
Times cited : (68)

References (19)
  • 4
    • 0026173242 scopus 로고
    • An ISFET-based calcium sensor using a photopolymerized polysiloxane membrane
    • Van Den Berg, A., Grisel, A. and Verney-Norberg, E. (1991) An ISFET-based calcium sensor using a photopolymerized polysiloxane membrane. Sensors & Actuators B4, 235-238.
    • (1991) Sensors & Actuators , vol.B4 , pp. 235-238
    • Van Den Berg, A.1    Grisel, A.2    Verney-Norberg, E.3
  • 5
    • 0029001184 scopus 로고
    • The remarkable similarity between the acid-base properties of ISFET and proteins and the consequences for the design of ISFET biosensors
    • Bergveld, P., Van Hal, R. E. G. and Eijkel, J. C. T. (1995) The remarkable similarity between the acid-base properties of ISFET and proteins and the consequences for the design of ISFET biosensors. Biosensors & Bioelectronics 10, 405-414.
    • (1995) Biosensors & Bioelectronics , vol.10 , pp. 405-414
    • Bergveld, P.1    Van Hal, R.E.G.2    Eijkel, J.C.T.3
  • 6
    • 0000586531 scopus 로고
    • Photocurable polymer matrices for potassium sensitive ion-selective electrode membrane
    • Bratov, A., Abramova, N., Muñoz, J., Dominguez, C., Alegret, S. and Bartrolí, J. (1995) Photocurable polymer matrices for potassium sensitive ion-selective electrode membrane. Anal. Chem. 67, 3589-3595.
    • (1995) Anal. Chem. , vol.67 , pp. 3589-3595
    • Bratov, A.1    Abramova, N.2    Muñoz, J.3    Dominguez, C.4    Alegret, S.5    Bartrolí, J.6
  • 7
    • 0029290625 scopus 로고
    • Photocurable polymers applied as encapsulating materials for ISFETs mass production
    • Bratov, A., Muñoz, J., Dominguez, C. and Bartrolí, J. (1995a) Photocurable polymers applied as encapsulating materials for ISFETs mass production. Sensors & Actuators 25, 823-825.
    • (1995) Sensors & Actuators , vol.25 , pp. 823-825
    • Bratov, A.1    Muñoz, J.2    Dominguez, C.3    Bartrolí, J.4
  • 9
    • 0026216161 scopus 로고
    • Electrochemical performance, biocompatibility and adhesion of new polymer matrices for solid state ion sensors
    • Cha, G. S., Liu, D., Meyerhoff, M. E., Cantor, H. C., Midgley, A. R., Goldberg, H. D. and Brown, R. B. (1991) Electrochemical performance, biocompatibility and adhesion of new polymer matrices for solid state ion sensors. Anal. Chem. 63, 1666-1672.
    • (1991) Anal. Chem. , vol.63 , pp. 1666-1672
    • Cha, G.S.1    Liu, D.2    Meyerhoff, M.E.3    Cantor, H.C.4    Midgley, A.R.5    Goldberg, H.D.6    Brown, R.B.7
  • 10
    • 0026152395 scopus 로고
    • Membranes for chemical sensors
    • Clechet, P. (1991) Membranes for chemical sensors. Sensors & Actuators B4, 53-63.
    • (1991) Sensors & Actuators , vol.B4 , pp. 53-63
    • Clechet, P.1
  • 11
    • 0001156237 scopus 로고
    • Ion-selective microchemical sensors with reduced preconditionong time. Membrane biostability studies and applications in blood analysis
    • Cosofret, V., Erdösy, M., Lindner, E., Johnson, T. A., Buck, R., Kao, W. J., Neuman, M. R. and Anderson, J. M. (1994) Ion-selective microchemical sensors with reduced preconditionong time. Membrane biostability studies and applications in blood analysis. Anal. Lett. 27, 3039-3063.
    • (1994) Anal. Lett. , vol.27 , pp. 3039-3063
    • Cosofret, V.1    Erdösy, M.2    Lindner, E.3    Johnson, T.A.4    Buck, R.5    Kao, W.J.6    Neuman, M.R.7    Anderson, J.M.8
  • 12
    • 0026013222 scopus 로고
    • Photolithographically patternable nitrate-sensitive acrylate-based membrane
    • Dumschat, C, Frömer, R., Rautschek, H., Müller, H. and Timpe, H. J. (1991) Photolithographically patternable nitrate-sensitive acrylate-based membrane. Anal. Chim. Acta 243, 179-182.
    • (1991) Anal. Chim. Acta , vol.243 , pp. 179-182
    • Dumschat, C.1    Frömer, R.2    Rautschek, H.3    Müller, H.4    Timpe, H.J.5
  • 13
    • 0022026038 scopus 로고
    • Integrated enzyme FETs for simultaneous detection of urea and glucose
    • Miyahara, Y., Moriizumi, T. and Ichimura, K. (1985) Integrated enzyme FETs for simultaneous detection of urea and glucose. Sensors & Actuators 7, 1-10.
    • (1985) Sensors & Actuators , vol.7 , pp. 1-10
    • Miyahara, Y.1    Moriizumi, T.2    Ichimura, K.3
  • 14
    • 0000234158 scopus 로고
    • Modified poly(vinyl chloride) matrix membranes for ion-selective field effect transistor sensors
    • Moody, G. J., Thomas, J. D. R. and Slater, J. M. (1988) Modified poly(vinyl chloride) matrix membranes for ion-selective field effect transistor sensors. Analyst 113, 1703-1707.
    • (1988) Analyst , vol.113 , pp. 1703-1707
    • Moody, G.J.1    Thomas, J.D.R.2    Slater, J.M.3
  • 15
    • 0030171614 scopus 로고
    • Planar compatible polymer technology for packaging of chemical microsensors
    • Muñoz, J., Bratov, A., Mas, R., Bartrolí, J. and Dominguez, C. (1995) Planar compatible polymer technology for packaging of chemical microsensors. J. Electrochem. Soc. 143, 2020-2025.
    • (1995) J. Electrochem. Soc. , vol.143 , pp. 2020-2025
    • Muñoz, J.1    Bratov, A.2    Mas, R.3    Bartrolí, J.4    Dominguez, C.5
  • 17
    • 0025226885 scopus 로고
    • Urushi matrix sodium, potassium, calcium and chloride-selective field effect transistors
    • Wakida, S., Yamane, H., Hishashi, K., Hiiro, K. and Ujira, Y. (1990) Urushi matrix sodium, potassium, calcium and chloride-selective field effect transistors. Sensors & Actuators B1, 412-415.
    • (1990) Sensors & Actuators , vol.B1 , pp. 412-415
    • Wakida, S.1    Yamane, H.2    Hishashi, K.3    Hiiro, K.4    Ujira, Y.5
  • 19
    • 0026995517 scopus 로고
    • Analytical applications of pH-ISFETs
    • Vlasov, Y. G. and Bratov, D. (1992) Analytical applications of pH-ISFETs, Sensors & Actuators B10, 1-6.
    • (1992) Sensors & Actuators , vol.B10 , pp. 1-6
    • Vlasov, Y.G.1    Bratov, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.