메뉴 건너뛰기




Volumn 38, Issue 10, 1997, Pages 1521-1528

Comparison of modified technetium-99m albumin and technetium-99m red blood cells for equilibrium ventriculography

Author keywords

Gated blood pool imaging; Technetium 99m DMP HSA; Technetium 99m labeled red blood cells

Indexed keywords

DIMERCAPTOPROPIONYL HUMAN SERUM ALBUMIN TC 99M; ERYTHROCYTE TC 99M; HUMAN SERUM ALBUMIN TC 99M; UNCLASSIFIED DRUG;

EID: 0030858717     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (31)
  • 1
    • 0028172335 scopus 로고
    • Prognostic assessment in coronary artery disease: Role of radionuclide angiography
    • Bonow RO. Prognostic assessment in coronary artery disease: role of radionuclide angiography. J Nucl Cordiol 1994;1:280-291.
    • (1994) J Nucl Cordiol , vol.1 , pp. 280-291
    • Bonow, R.O.1
  • 2
    • 0028557324 scopus 로고
    • Risk stratification of patients with coronary artery disease and left ventricular dysfunction by exercise radionuclide angiography and exercise electrocardiography
    • Mazzotta G, Pace L, Bonow RO. Risk stratification of patients with coronary artery disease and left ventricular dysfunction by exercise radionuclide angiography and exercise electrocardiography. J Nucl Cardiol 1994;1:529-536.
    • (1994) J Nucl Cardiol , vol.1 , pp. 529-536
    • Mazzotta, G.1    Pace, L.2    Bonow, R.O.3
  • 3
    • 0026076052 scopus 로고
    • Rest and exercise radionuclide angiography for diagnosis in chronic ischemic heart disease
    • Gibbons RJ. Rest and exercise radionuclide angiography for diagnosis in chronic ischemic heart disease. Circulation 1991;84:93-99.
    • (1991) Circulation , vol.84 , pp. 93-99
    • Gibbons, R.J.1
  • 4
    • 0017773983 scopus 로고
    • Real-time radionuclide cineangiography in the noninvasive evaluation of global and regional left ventricular function at rest and during exercise in patients with coronary artery disease
    • Borer SL, Bacharach SL, Green MV, Kent KM, Epstein SE, Johnston GS. Real-time radionuclide cineangiography in the noninvasive evaluation of global and regional left ventricular function at rest and during exercise in patients with coronary artery disease. N Engl J Med 1977;296:839-844.
    • (1977) N Engl J Med , vol.296 , pp. 839-844
    • Borer, S.L.1    Bacharach, S.L.2    Green, M.V.3    Kent, K.M.4    Epstein, S.E.5    Johnston, G.S.6
  • 5
    • 0020591340 scopus 로고
    • Evaluation of left ventricular function by radionuclide angiography during exercise in normal subjects and in patients with chronic coronary artery disease
    • Iskandrian AS, Hakki AH, DePace NL, Manno B, Segal BL. Evaluation of left ventricular function by radionuclide angiography during exercise in normal subjects and in patients with chronic coronary artery disease. J Am Coll Cardiol 1983;1:1518-1529.
    • (1983) J Am Coll Cardiol , vol.1 , pp. 1518-1529
    • Iskandrian, A.S.1    Hakki, A.H.2    DePace, N.L.3    Manno, B.4    Segal, B.L.5
  • 7
    • 0025039001 scopus 로고
    • Prognostic value of radionuclide angiography in medically treated patients with coronary artery disease: A comparison with clinical and catheterization variables
    • Lee KL, Pryor DB, Pieper KS, et al. Prognostic value of radionuclide angiography in medically treated patients with coronary artery disease: a comparison with clinical and catheterization variables. Circulation 1990;82:1705-1717.
    • (1990) Circulation , vol.82 , pp. 1705-1717
    • Lee, K.L.1    Pryor, D.B.2    Pieper, K.S.3
  • 8
    • 0018191468 scopus 로고
    • Cardiac function at rest and during exercise in patients with coronary heart disease: Evaluation by radionuclide angiography
    • Rerych SK, Scholz PM, Newman GE, Sabiston DC, Jones RH. Cardiac function at rest and during exercise in patients with coronary heart disease: evaluation by radionuclide angiography. Ann Surg 1978;187:449-463.
    • (1978) Ann Surg , vol.187 , pp. 449-463
    • Rerych, S.K.1    Scholz, P.M.2    Newman, G.E.3    Sabiston, D.C.4    Jones, R.H.5
  • 9
    • 0021339977 scopus 로고
    • Prognostic indicators from radionuclide angiography in medically treated patients with coronary artery disease
    • Pryor DB, Harrell FE, Lee KL, et al. Prognostic indicators from radionuclide angiography in medically treated patients with coronary artery disease. Am J Cardiol 1984;53:18-22.
    • (1984) Am J Cardiol , vol.53 , pp. 18-22
    • Pryor, D.B.1    Harrell, F.E.2    Lee, K.L.3
  • 10
    • 0028127814 scopus 로고
    • Severe exercise-induced ischemia does not identify high risk patients with normal left ventricular function and one- or two-vessel coronary artery disease
    • Miller TD, Christian TF, Taliercio CP, Zinsmeister AR, Gibbons RJ. Severe exercise-induced ischemia does not identify high risk patients with normal left ventricular function and one- or two-vessel coronary artery disease. J Am Coll Cardiol 1994;23: 219-224.
    • (1994) J Am Coll Cardiol , vol.23 , pp. 219-224
    • Miller, T.D.1    Christian, T.F.2    Taliercio, C.P.3    Zinsmeister, A.R.4    Gibbons, R.J.5
  • 11
    • 0028336759 scopus 로고
    • Developments in echocardiography
    • Hartnell GG. Developments in echocardiography. Rodiol Clin North Am 1994;32:461-475.
    • (1994) Rodiol Clin North Am , vol.32 , pp. 461-475
    • Hartnell, G.G.1
  • 12
    • 0028275108 scopus 로고
    • Evaluation of cardiac function with ultrafast computed tomography
    • Thompson BH, Stanford W. Evaluation of cardiac function with ultrafast computed tomography. Radiol Clin North Am 1994;32:537-551.
    • (1994) Radiol Clin North Am , vol.32 , pp. 537-551
    • Thompson, B.H.1    Stanford, W.2
  • 14
    • 0020401148 scopus 로고
    • Limitations of comparing left ventricular volumes by two dimensional echocardiography, myocardial markers and cineangiography
    • Schnittger I, Fitzgerald PJ, Daughters GT, et al. Limitations of comparing left ventricular volumes by two dimensional echocardiography, myocardial markers and cineangiography. Am J Cardiol 1982;50:512-519.
    • (1982) Am J Cardiol , vol.50 , pp. 512-519
    • Schnittger, I.1    Fitzgerald, P.J.2    Daughters, G.T.3
  • 15
    • 0019471608 scopus 로고
    • Comparative accuracy of apical bi-plane cross-sectional echocardiography and gated equilibrium radionuclide angiography for estimating left ventricular size and performance
    • Starling MR, Crawford MH, Sorenson SG, Levi B, Richards KL, O'Rourke RA. Comparative accuracy of apical bi-plane cross-sectional echocardiography and gated equilibrium radionuclide angiography for estimating left ventricular size and performance. Circulation 1981;63:1075-1084.
    • (1981) Circulation , vol.63 , pp. 1075-1084
    • Starling, M.R.1    Crawford, M.H.2    Sorenson, S.G.3    Levi, B.4    Richards, K.L.5    O'Rourke, R.A.6
  • 16
    • 0018232442 scopus 로고
    • Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo and with technetium-99m human serum albumin
    • Thrall JH, Freitas JE, Swanson D, et al. Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo and with technetium-99m human serum albumin. J Nucl Med 1978;19:796-803.
    • (1978) J Nucl Med , vol.19 , pp. 796-803
    • Thrall, J.H.1    Freitas, J.E.2    Swanson, D.3
  • 17
    • 0018901365 scopus 로고
    • 99mTc-labeled human serum albumin and in vitro labeled red blood cells for blood pool studies
    • 99mTc-labeled human serum albumin and in vitro labeled red blood cells for blood pool studies. Clin Nucl Med 1980;5:166-169.
    • (1980) Clin Nucl Med , vol.5 , pp. 166-169
    • Atkins, H.L.1    Klopper, J.F.2    Ansari, A.N.3
  • 19
    • 0026696123 scopus 로고
    • Health officials reacting to infection mishaps
    • Rojas-Burke J. Health officials reacting to infection mishaps. J Nucl Med 1992;33: 13N-14N.
    • (1992) J Nucl Med , vol.33
    • Rojas-Burke, J.1
  • 20
    • 9844246009 scopus 로고
    • Misadministration spurs statewide inspection of California nuclear medicine departments
    • Silverman L. Misadministration spurs statewide inspection of California nuclear medicine departments. J Nucl Med 1992;33:32N-33N.
    • (1992) J Nucl Med , vol.33
    • Silverman, L.1
  • 21
    • 0025228402 scopus 로고
    • Failure of zidovudine prophylaxis in accidental exposure to HIV-1
    • Lange JMA, Boucher CAB, Hollak CEM, et al. Failure of zidovudine prophylaxis in accidental exposure to HIV-1. N Engl J Med 1990;19:1375-1377.
    • (1990) N Engl J Med , vol.19 , pp. 1375-1377
    • Lange, J.M.A.1    Boucher, C.A.B.2    Hollak, C.E.M.3
  • 22
    • 0027179915 scopus 로고
    • Technetium-99m mercaptoalbumin as a potential substitute for technetium-99m-labeled red blood cells
    • Verbeke K, Vanbilloen HP, De Roo MJ, Verbruggen AM. Technetium-99m mercaptoalbumin as a potential substitute for technetium-99m-labeled red blood cells. Eur J Nucl Med 1993;20:473-482.
    • (1993) Eur J Nucl Med , vol.20 , pp. 473-482
    • Verbeke, K.1    Vanbilloen, H.P.2    De Roo, M.J.3    Verbruggen, A.M.4
  • 23
    • 0028040887 scopus 로고
    • First evaluation of technetium-99m dimercaptopropionyl albumin as a possible agent for ventriculography in a volunteer
    • Verbeke KA, Vanhecke WB, Mortelmans LA, Verbruggen AM. First evaluation of technetium-99m dimercaptopropionyl albumin as a possible agent for ventriculography in a volunteer. Eur J Nucl Med 1994;21:906-912.
    • (1994) Eur J Nucl Med , vol.21 , pp. 906-912
    • Verbeke, K.A.1    Vanhecke, W.B.2    Mortelmans, L.A.3    Verbruggen, A.M.4
  • 24
    • 0028926515 scopus 로고
    • Failure to label red blood cells adequately in daily practice using an in vivo method: Methodological and clinical considerations
    • Hambÿe AS, Vandermeiren R, Vervaet A, Vandevivere J. Failure to label red blood cells adequately in daily practice using an in vivo method: methodological and clinical considerations. Eur J Nucl Med 1995;22:61-67.
    • (1995) Eur J Nucl Med , vol.22 , pp. 61-67
    • Hambÿe, A.S.1    Vandermeiren, R.2    Vervaet, A.3    Vandevivere, J.4
  • 25
    • 0001802176 scopus 로고
    • Some common problems in medical research, method comparison studies
    • Altman DG, ed. London: Chapman and Hall
    • Altman DG. Some common problems in medical research, method comparison studies. In: Altman DG, ed. Practical statistics for medical research, 1st ed. London: Chapman and Hall; 1991:396-403.
    • (1991) Practical Statistics for Medical Research, 1st Ed. , pp. 396-403
    • Altman, D.G.1
  • 28
    • 0028047238 scopus 로고
    • Poor quality red blood cell labeling with technetium-99m: Case report and review of the literature
    • Adalet I, Gantez S. Poor quality red blood cell labeling with technetium-99m: case report and review of the literature. Eur J Nucl Med 1994;21:173-175.
    • (1994) Eur J Nucl Med , vol.21 , pp. 173-175
    • Adalet, I.1    Gantez, S.2
  • 29
    • 0022744318 scopus 로고
    • Effect of Sn(II) ion concentration and heparin on technetium-99m red blood cell labeling
    • Rao SA, Knobel J, Collier BD, et al. Effect of Sn(II) ion concentration and heparin on technetium-99m red blood cell labeling. J Nucl Med 1986;27:1202-1206.
    • (1986) J Nucl Med , vol.27 , pp. 1202-1206
    • Rao, S.A.1    Knobel, J.2    Collier, B.D.3
  • 30
    • 8044245766 scopus 로고
    • Interference of patient medications in the radiolabelling of blood cells: In vivo and in vitro effects
    • Sampson CB. Interference of patient medications in the radiolabelling of blood cells: in vivo and in vitro effects [Abstract]. Eur J Nucl Med 1994;21:S17.
    • (1994) Eur J Nucl Med , vol.21
    • Sampson, C.B.1
  • 31
    • 0021061356 scopus 로고
    • Pitfall to modified in vivo method of technetium-99m red blood cell labeling: Iodinated contrast media
    • Tatum JL, Burke TS, Hirsch JL, et al. Pitfall to modified in vivo method of technetium-99m red blood cell labeling: iodinated contrast media. Clin Nucl Med 1983;8:585-587.
    • (1983) Clin Nucl Med , vol.8 , pp. 585-587
    • Tatum, J.L.1    Burke, T.S.2    Hirsch, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.