메뉴 건너뛰기




Volumn 43, Issue 10, 1997, Pages 1944-1951

Candidate reference methods for hemoglobin A(1c) based on peptide mapping

Author keywords

[No Author keywords available]

Indexed keywords

GLYCOSYLATED HEMOGLOBIN; HEMOGLOBIN A1C; HEMOGLOBIN BETA CHAIN; HEXAPEPTIDE;

EID: 0030853707     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/43.10.1944     Document Type: Article
Times cited : (162)

References (27)
  • 1
    • 0019223025 scopus 로고
    • Sites of nonenzymatic glycosylation of human hemoglobin A
    • Shapiro R, McManus MJ, Zolut C, Bunn HF. Sites of nonenzymatic glycosylation of human hemoglobin A. J Biol Chem 1980;255: 3120-27.
    • (1980) J Biol Chem , vol.255 , pp. 3120-3127
    • Shapiro, R.1    McManus, M.J.2    Zolut, C.3    Bunn, H.F.4
  • 3
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
    • The Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993;329:977-86.
    • (1993) N Engl J Med , vol.329 , pp. 977-986
  • 4
    • 0027519381 scopus 로고
    • Lessons from the Diabetes Control and Complications Trial
    • Santiago JV. Lessons from the Diabetes Control and Complications Trial. Diabetes 1993;42:1549-54.
    • (1993) Diabetes , vol.42 , pp. 1549-1554
    • Santiago, J.V.1
  • 5
    • 0028212418 scopus 로고
    • Glycated protein update. Implications of recent studies, including the Diabetes Control and Complications Trial
    • Benjamin J, Sacks DB. Glycated protein update. Implications of recent studies, including the Diabetes Control and Complications Trial. Clin Chem 1994;40:683-7.
    • (1994) Clin Chem , vol.40 , pp. 683-687
    • Benjamin, J.1    Sacks, D.B.2
  • 6
    • 0028103882 scopus 로고
    • Is glycohemoglobin testing useful in diabetes mellitus? Lessons from the Diabetes Control and Complications Trial
    • Goldstein D, Little R, Wiedmeyer H-M, England JD, Rohlfing CL, Wilke AL. Is glycohemoglobin testing useful in diabetes mellitus? Lessons from the Diabetes Control and Complications Trial. Clin Chem 1994;40:1937-40.
    • (1994) Clin Chem , vol.40 , pp. 1937-1940
    • Goldstein, D.1    Little, R.2    Wiedmeyer, H.-M.3    England, J.D.4    Rohlfing, C.L.5    Wilke, A.L.6
  • 7
    • 0027102839 scopus 로고
    • Standardization, calibration, the care of diabetic patients
    • Bruns DE. Standardization, calibration, the care of diabetic patients [Editorial]. Clin Chem 1992;38:2363-4.
    • (1992) Clin Chem , vol.38 , pp. 2363-2364
    • Bruns, D.E.1
  • 9
    • 0028084320 scopus 로고
    • Effect of calibration on dispersion of glycohemoglobin values determined by 111 laboratories using 21 methods
    • Weykamp CW, Penders TJ, Muskiet FA, van der Slik W. Effect of calibration on dispersion of glycohemoglobin values determined by 111 laboratories using 21 methods. Clin Chem 1994;40:138-44.
    • (1994) Clin Chem , vol.40 , pp. 138-144
    • Weykamp, C.W.1    Penders, T.J.2    Muskiet, F.A.3    Van Der Slik, W.4
  • 10
    • 0028855786 scopus 로고
    • Standardization of glycohemoglobin results and reference values in whole blood studied in 103 laboratories using 20 methods
    • Weykamp CW, Penders TJ, Miedema K, Muskiet FA, van der Slik W. Standardization of glycohemoglobin results and reference values in whole blood studied in 103 laboratories using 20 methods. Clin Chem 1995;41:82-6.
    • (1995) Clin Chem , vol.41 , pp. 82-86
    • Weykamp, C.W.1    Penders, T.J.2    Miedema, K.3    Muskiet, F.A.4    Van Der Slik, W.5
  • 12
    • 84942964849 scopus 로고
    • Ethylene glycol-stabilized haemolysates for glycated haemoglobin assay. Further analytical investigations and applications to quality control programmes
    • Mosca A, Carpinelli A, Bonini PA. Ethylene glycol-stabilized haemolysates for glycated haemoglobin assay. Further analytical investigations and applications to quality control programmes. J Clin Chem Clin Biochem 1987;25:447-50.
    • (1987) J Clin Chem Clin Biochem , vol.25 , pp. 447-450
    • Mosca, A.1    Carpinelli, A.2    Bonini, P.A.3
  • 13
    • 0030159203 scopus 로고    scopus 로고
    • 1c/glycohemoglobin determinations
    • 1c/glycohemoglobin determinations. J IFCC 1996;9:62-7.
    • (1996) J IFCC , vol.9 , pp. 62-67
    • Hoelzel, W.1    Miedema, K.2
  • 14
    • 0020591947 scopus 로고
    • Application of affinity chromatography for separation and quantification of glycosylated hemoglobins
    • Abraham EC, Perry RE, Stallings M. Application of affinity chromatography for separation and quantification of glycosylated hemoglobins. J Lab Clin Med 1983;102:187-97.
    • (1983) J Lab Clin Med , vol.102 , pp. 187-197
    • Abraham, E.C.1    Perry, R.E.2    Stallings, M.3
  • 15
    • 0020622110 scopus 로고
    • Characterization of glycosylated hemoglobins: Relevance to monitoring of diabetic control and analysis of other proteins
    • Garlick RL, Mazer JS, Higgins PJ, Bunn HF. Characterization of glycosylated hemoglobins: relevance to monitoring of diabetic control and analysis of other proteins. J Clin Invest 1983;71: 1062-72.
    • (1983) J Clin Invest , vol.71 , pp. 1062-1072
    • Garlick, R.L.1    Mazer, J.S.2    Higgins, P.J.3    Bunn, H.F.4
  • 16
    • 0021797138 scopus 로고
    • Effect of temperature on quantifying glycated (glycosylated) hemoglobin by cation exchange chromatography
    • Fluckinger R, Woodtli T. Effect of temperature on quantifying glycated (glycosylated) hemoglobin by cation exchange chromatography. Clin Chem 1985;31:114-7.
    • (1985) Clin Chem , vol.31 , pp. 114-117
    • Fluckinger, R.1    Woodtli, T.2
  • 17
  • 19
    • 0030606922 scopus 로고    scopus 로고
    • 1c measurement by cation exchange liquid chromatography. Evaluation of a Mono S column method
    • 1c measurement by cation exchange liquid chromatography. Evaluation of a Mono S column method. Clin Chim Acta 1996;253:159-69.
    • (1996) Clin Chim Acta , vol.253 , pp. 159-169
    • Koskinen, L.K.1
  • 20
    • 0028292556 scopus 로고
    • Improved method for analysis of glycated haemoglobin by ion exchange chromatography
    • Eckerbom S, Bergqvist Y, Jeppsson J-O. Improved method for analysis of glycated haemoglobin by ion exchange chromatography. Ann Clin Biochem 1994;31:1-6.
    • (1994) Ann Clin Biochem , vol.31 , pp. 1-6
    • Eckerbom, S.1    Bergqvist, Y.2    Jeppsson, J.-O.3
  • 21
    • 0022929898 scopus 로고
    • 1c by a new liquid-chromatographic assay: Methodology, clinical utility and relation to glucose tolerance evaluated
    • 1c by a new liquid-chromatographic assay: methodology, clinical utility and relation to glucose tolerance evaluated. Clin Chem 1986;32:1867-72.
    • (1986) Clin Chem , vol.32 , pp. 1867-1872
    • Jeppsson, J.-O.1    Jerntorp, P.2    Sundkvist, G.3    Englund, H.4    Nylund, U.5
  • 24
    • 0029864587 scopus 로고    scopus 로고
    • Analytical specifications of Reference Methods. Compilation and critical discussion (from members of the European EQA-Organizers Working Group B)
    • Stöckl D, Franzini C, Kratochvila J, Middle J, Ricos C, Siekmann L, Thienpont LM. Analytical specifications of Reference Methods. Compilation and critical discussion (from members of the European EQA-Organizers Working Group B) [Review]. Eur J Clin Chem Clin Biochem 1996;34:319-37.
    • (1996) Eur J Clin Chem Clin Biochem , vol.34 , pp. 319-337
    • Stöckl, D.1    Franzini, C.2    Kratochvila, J.3    Middle, J.4    Ricos, C.5    Siekmann, L.6    Thienpont, L.M.7
  • 25
    • 0024438708 scopus 로고
    • Electro-spray ionization for mass spectrometry of large biomolecules
    • Fenn JB, Mann M, Meng C, Wong SF, Whitehouse CM. Electro-spray ionization for mass spectrometry of large biomolecules. Science 1989;246:64-71.
    • (1989) Science , vol.246 , pp. 64-71
    • Fenn, J.B.1    Mann, M.2    Meng, C.3    Wong, S.F.4    Whitehouse, C.M.5
  • 26
    • 0014080456 scopus 로고
    • Recommendations for hemoglobinometry in human blood
    • International Committee for Standardization in Haematology. Recommendations for hemoglobinometry in human blood. Br J Haematol 1967;13:71-5.
    • (1967) Br J Haematol , vol.13 , pp. 71-75
  • 27
    • 0021284728 scopus 로고
    • Hb-Linköping (β 36 Pro-Thr). A new hemoglobin mutant characterized by reversed phase high performance liquid chromatography
    • Jeppsson J-O, Källman I, Lindgren G, Fägerstam LG. Hb-Linköping (β 36 Pro-Thr). A new hemoglobin mutant characterized by reversed phase high performance liquid chromatography. J Chromatogr 1984;297:31-6.
    • (1984) J Chromatogr , vol.297 , pp. 31-36
    • Jeppsson, J.-O.1    Källman, I.2    Lindgren, G.3    Fägerstam, L.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.