메뉴 건너뛰기




Volumn 100, Issue 2, 1997, Pages 252-254

Carbon monoxide and bilirubin production in neonates

Author keywords

[No Author keywords available]

Indexed keywords

BILIRUBIN; BILIVERDIN; CARBON MONOXIDE;

EID: 0030851657     PISSN: 00314005     EISSN: None     Source Type: Journal    
DOI: 10.1542/peds.100.2.252     Document Type: Article
Times cited : (61)

References (7)
  • 1
    • 0028086109 scopus 로고
    • Practice parameter: Management of hyperbilirubinemia in the healthy term newborn
    • American Academy of Pediatrics. Practice parameter: management of hyperbilirubinemia in the healthy term newborn. Pediatrics. 1994;94: 558-565
    • (1994) Pediatrics , vol.94 , pp. 558-565
  • 2
    • 0018534391 scopus 로고
    • Effect of erythrocyte destruction on the pulmonary excretion rate of carbon monoxide in adult male Wistar rats
    • Stevenson DK, Ostrander CR, Johnson JD. Effect of erythrocyte destruction on the pulmonary excretion rate of carbon monoxide in adult male Wistar rats. J Lab Clin Med. 1979;94:649-654
    • (1979) J Lab Clin Med , vol.94 , pp. 649-654
    • Stevenson, D.K.1    Ostrander, C.R.2    Johnson, J.D.3
  • 3
    • 0028896481 scopus 로고
    • Glucose-6-phosphate dehydrogenase deficiency and carboxyhemoglobin concentrations associated with bilirubin-related morbidity and death in Nigerian infants
    • Slusher TM, Vreman HJ, McLaren DW, Lewison LJ, Brown AK, Stevenson DK. Glucose-6-phosphate dehydrogenase deficiency and carboxyhemoglobin concentrations associated with bilirubin-related morbidity and death in Nigerian infants. J Pediatr. 1994;126:102-108
    • (1994) J Pediatr , vol.126 , pp. 102-108
    • Slusher, T.M.1    Vreman, H.J.2    McLaren, D.W.3    Lewison, L.J.4    Brown, A.K.5    Stevenson, D.K.6
  • 4
    • 0028089756 scopus 로고
    • Semiportable electrochemical instrument for determining carbon monoxide in breath
    • Vreman HJ, Stevenson DK, Oh W, et al. Semiportable electrochemical instrument for determining carbon monoxide in breath. Clin Chem. 1994;40:1927-1933
    • (1994) Clin Chem , vol.40 , pp. 1927-1933
    • Vreman, H.J.1    Stevenson, D.K.2    Oh, W.3
  • 5
    • 0027967742 scopus 로고
    • Bilirubin production in healthy term infants as measured by carbon monoxide in breath
    • Stevenson DK, Vreman HJ, Oh W, et al. Bilirubin production in healthy term infants as measured by carbon monoxide in breath. Clin Chem. 1994;40:1934-1939
    • (1994) Clin Chem , vol.40 , pp. 1934-1939
    • Stevenson, D.K.1    Vreman, H.J.2    Oh, W.3
  • 6
    • 0030061342 scopus 로고    scopus 로고
    • Evaluation of a fully automated end-tidal carbon monoxide instrument for breath analysis
    • Vreman HJ, Baxter LM, Stone RT, Stevenson DK. Evaluation of a fully automated end-tidal carbon monoxide instrument for breath analysis. Clin Chem. 1996;42:50-56
    • (1996) Clin Chem , vol.42 , pp. 50-56
    • Vreman, H.J.1    Baxter, L.M.2    Stone, R.T.3    Stevenson, D.K.4
  • 7
    • 0030007784 scopus 로고    scopus 로고
    • Interlaboratory variability of bilirubin measurements
    • Vreman HJ, Verter J, Stevenson DK, et al. Interlaboratory variability of bilirubin measurements. Clin Chem. 1996;42:869-873
    • (1996) Clin Chem , vol.42 , pp. 869-873
    • Vreman, H.J.1    Verter, J.2    Stevenson, D.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.