메뉴 건너뛰기




Volumn 23, Issue 5, 1997, Pages 793-796

Acoustic cavitation nuclei survive the apparent ultrasonic destruction of albunex® microspheres

Author keywords

Albunex microspheres; Cavitation nuclei; Ultrasonic hemolysis

Indexed keywords

BLOOD; CAVITATION; CELLS; PHYSIOLOGY; ULTRASONIC EFFECTS;

EID: 0030841811     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(97)00008-2     Document Type: Article
Times cited : (28)

References (12)
  • 2
    • 0025123070 scopus 로고
    • Ultrasonic characterization of Albunex®, a new contrast agent
    • Bleeker HJ, Shung KK, Barnhart JL. Ultrasonic characterization of Albunex®, a new contrast agent. J Acoust Soc Am 1990; 87:1792-1797.
    • (1990) J Acoust Soc Am , vol.87
    • Bleeker, H.J.1    Shung, K.K.2    Barnhart, J.L.3
  • 3
    • 0029760959 scopus 로고    scopus 로고
    • Hemolysis of Albu-nex®-supplemented, 40% hematocrit human erythrocytes in vitro by 1 MHz pulsed ultrasound: Acoustic pressure and pulse length dependence
    • Brayman AA, Azadniv M, Cox C, Miller MW. Hemolysis of Albu-nex®-supplemented, 40% hematocrit human erythrocytes in vitro by 1 MHz pulsed ultrasound: Acoustic pressure and pulse length dependence. Ultrasound Med Biol 1996;22:927-938.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 927-938
    • Brayman, A.A.1    Azadniv, M.2    Cox, C.3    Miller, M.W.4
  • 5
    • 0026782293 scopus 로고
    • Apparent contribution of respiratory gas exchange to the in vitro "cell density effect" in ultrasonic cell lysis
    • Brayman AA, Doida Y, Miller MW. Apparent contribution of respiratory gas exchange to the in vitro "cell density effect" in ultrasonic cell lysis. Ultrasound Med Biol 1992;18:701-714.
    • (1992) Ultrasound Med Biol , vol.18 , pp. 701-714
    • Brayman, A.A.1    Doida, Y.2    Miller, M.W.3
  • 8
    • 0028899059 scopus 로고
    • Effect of a stabilized microbubble contrast agent on CW ultrasound-induced red blood cell lysis in vitro
    • Miller MW, Azadniv M, Doida Y, Brayman AA. Effect of a stabilized microbubble contrast agent on CW ultrasound-induced red blood cell lysis in vitro. Echocardiography 1995;12:1-12.
    • (1995) Echocardiography , vol.12 , pp. 1-12
    • Miller, M.W.1    Azadniv, M.2    Doida, Y.3    Brayman, A.A.4
  • 9
    • 0030442881 scopus 로고    scopus 로고
    • A review of in vitro bioeffects of inertial cavitation from a mechanistic perspective
    • Miller MW, Miller DL, Brayman AA. A review of in vitro bioeffects of inertial cavitation from a mechanistic perspective. Ultrasound Med Biol 1996;22:1131-1154.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 1131-1154
    • Miller, M.W.1    Miller, D.L.2    Brayman, A.A.3
  • 10
    • 0344227852 scopus 로고
    • Reproducibility of albumin microbubble backscatter measurement: Influence of acoustic output
    • Vandenberg BF. Reproducibility of albumin microbubble backscatter measurement: Influence of acoustic output [abstract]. Clin Res 1990;38:887A.
    • (1990) Clin Res , vol.38
    • Vandenberg, B.F.1
  • 12
    • 0026248783 scopus 로고
    • Relation of mean pixel intensity to concentration of sonicated albumin microspheres: Effects of ultrasound system settings
    • Wray RA, Quinones MA, Zoghbi WA, Cheirif J. Relation of mean pixel intensity to concentration of sonicated albumin microspheres: Effects of ultrasound system settings. Clin Cardiol 1991;14:23-28.
    • (1991) Clin Cardiol , vol.14 , pp. 23-28
    • Wray, R.A.1    Quinones, M.A.2    Zoghbi, W.A.3    Cheirif, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.