메뉴 건너뛰기




Volumn 21, Issue 7, 1997, Pages 635-638

Chronic animal experiment with magnetically suspended centrifugal pump

Author keywords

Long term ventricular assist; Magnetically suspended centrifugal pump

Indexed keywords

BLOOD VESSELS;

EID: 0030834136     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1525-1594.1997.tb03713.x     Document Type: Review
Times cited : (9)

References (7)
  • 1
    • 0026689559 scopus 로고
    • Centrifugal blood pump with a magnetically suspended impeller
    • Akamatsu T, Nakazeki T, Itoh H. Centrifugal blood pump with a magnetically suspended impeller. Artif Organs 1992;16: 305-8.
    • (1992) Artif Organs , vol.16 , pp. 305-308
    • Akamatsu, T.1    Nakazeki, T.2    Itoh, H.3
  • 2
    • 0026689559 scopus 로고
    • Recent development of a centrifugal blood pump with a magnetically suspended impeller
    • Akutsu T, Koyanagi H, eds. Tokyo: Springer-Verlag
    • Akamatsu T, Nakazeki T. Recent development of a centrifugal blood pump with a magnetically suspended impeller. In: Akutsu T, Koyanagi H, eds. Heart replacement-artificial heart 4. Tokyo: Springer-Verlag, 1993:305-8.
    • (1993) Heart Replacement-artificial Heart 4 , pp. 305-308
    • Akamatsu, T.1    Nakazeki, T.2
  • 3
    • 0029142494 scopus 로고
    • Recent studies of the centrifugal blood pump with a magnetically suspended impeller
    • Akamatsu T, Tsukiya T, Nishimura K, Park CH, Nakazeki T. Recent studies of the centrifugal blood pump with a magnetically suspended impeller. Artif Organs 1995;19:631-4.
    • (1995) Artif Organs , vol.19 , pp. 631-634
    • Akamatsu, T.1    Tsukiya, T.2    Nishimura, K.3    Park, C.H.4    Nakazeki, T.5
  • 5
    • 0030053665 scopus 로고    scopus 로고
    • Development of a magnetically suspended centrifugal pump as a cardiac assist device for long-term application
    • Nishimura K, Park CH, Akamatsu T, Yamada T, Ban T. Development of a magnetically suspended centrifugal pump as a cardiac assist device for long-term application. ASAIO J 1996; 42:68-71.
    • (1996) ASAIO J , vol.42 , pp. 68-71
    • Nishimura, K.1    Park, C.H.2    Akamatsu, T.3    Yamada, T.4    Ban, T.5
  • 7
    • 0029956030 scopus 로고    scopus 로고
    • Indirect measurement of flow rate and pressure difference and operation mode of the centrifugal blood pump with magnetically suspended impeller
    • Tsukiya T, Akamatsu T, Nishimura K, Park CH. Indirect measurement of flow rate and pressure difference and operation mode of the centrifugal blood pump with magnetically suspended impeller. Jpn J Artif Organs 1996;25:249-54.
    • (1996) Jpn J Artif Organs , vol.25 , pp. 249-254
    • Tsukiya, T.1    Akamatsu, T.2    Nishimura, K.3    Park, C.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.