Quality Assurance in radiation therapy: systematic evaluation of errors during the treatment execution
-
Blanco, S., Lopez-Bote, M. and Desco, M. Quality Assurance in radiation therapy: systematic evaluation of errors during the treatment execution. Radiother. Oncol. 8: 256-261.
-
Radiother. Oncol.
, vol.8
, pp. 256-261
-
-
Blanco, S.1
Lopez-Bote, M.2
Desco, M.3
-
2
-
-
0027482664
-
Human errors in the calculation of monitor unit in clinical radiotherapy practice
-
Calandrino, R., Cattaneo, G.M., del Vecchio, A., Fiorino, C., Longobardi, B. and Signorotto, P. Human errors in the calculation of monitor unit in clinical radiotherapy practice. Radiother. Oncol. 28: 86-88, 1993.
-
(1993)
Radiother. Oncol.
, vol.28
, pp. 86-88
-
-
Calandrino, R.1
Cattaneo, G.M.2
Del Vecchio, A.3
Fiorino, C.4
Longobardi, B.5
Signorotto, P.6
-
3
-
-
0027691059
-
The role of in-vivo dosimetry
-
Garavaglia, G., Johansson, K.A., Leunens, G. and Mijnher, B. The role of in-vivo dosimetry. Radiother. Oncol. 29: 281-282, 1993.
-
(1993)
Radiother. Oncol.
, vol.29
, pp. 281-282
-
-
Garavaglia, G.1
Johansson, K.A.2
Leunens, G.3
Mijnher, B.4
-
4
-
-
0015827035
-
Accuracy in clinical dosimetry
-
Kartha, P.K.I., Chung Bin, A. and Hendrickson, F.R. Accuracy in clinical dosimetry. Br. J. Radiol. 46: 1083, 1973.
-
(1973)
Br. J. Radiol.
, vol.46
, pp. 1083
-
-
Kartha, P.K.I.1
Chung Bin, A.2
Hendrickson, F.R.3
-
5
-
-
0028230872
-
Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40
-
Kutcher, G.J., Coia, L., Gillin, et al. Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40. Med. Phys. 21: 581-618, 1994.
-
(1994)
Med. Phys.
, vol.21
, pp. 581-618
-
-
Kutcher, G.J.1
Coia, L.2
Gillin et, al.3
-
7
-
-
0026563447
-
Detection of systematic patient setup errors by portal film analysis
-
Lebesque, J.V., Bel, A., Bijhold, J. and Hart, A.A.M. Detection of systematic patient setup errors by portal film analysis. Radiother. Oncol. 23: 198, 1992.
-
(1992)
Radiother. Oncol.
, vol.23
, pp. 198
-
-
Lebesque, J.V.1
Bel, A.2
Bijhold, J.3
Hart, A.A.M.4
-
8
-
-
0025166575
-
Quality assurance in radiotherapy by in-vivo dosimetry. 1. Entrance dose measurements, a reliable procedure
-
Leunens, G., van Dam, J., Dutreix, A. and van der Schueren, E. Quality assurance in radiotherapy by in-vivo dosimetry. 1. Entrance dose measurements, a reliable procedure. Radiother. Oncol. 17: 141-151, 1990.
-
(1990)
Radiother. Oncol.
, vol.17
, pp. 141-151
-
-
Leunens, G.1
Van Dam, J.2
Dutreix, A.3
Van Der Schueren, E.4
-
9
-
-
0026587135
-
Human errors in data transfer during the preparation and delivery of radiation treatment affecting the final result: 'garbage in, garbage out'
-
Leunens, G., Verstrate, J., Van der Gogaert, W., Van Dam, J., Dutreix, A. and Van der Schueren, E. Human errors in data transfer during the preparation and delivery of radiation treatment affecting the final result: 'garbage in, garbage out'. Radiother. Oncol. 23: 217-222, 1992.
-
(1992)
Radiother. Oncol.
, vol.23
, pp. 217-222
-
-
Leunens, G.1
Verstrate, J.2
Van Der Gogaert, W.3
Van Dam, J.4
Dutreix, A.5
Van Der Schueren, E.6
-
10
-
-
0017133803
-
The value of frequent verification films in reducing localization errors in the irradiation of complex fields
-
Marks, J.E., Haus, A.G., Sutton, H.G. and Griem, M.L. The value of frequent verification films in reducing localization errors in the irradiation of complex fields. Cancer 37: 2755-2761, 1976.
-
(1976)
Cancer
, vol.37
, pp. 2755-2761
-
-
Marks, J.E.1
Haus, A.G.2
Sutton, H.G.3
Griem, M.L.4
-
11
-
-
0028958815
-
Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry
-
Noël, A., Aletti, P., Bey, P. and Malissard, L. Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry. Radiother. Oncol. 34: 144-151, 1995.
-
(1995)
Radiother. Oncol.
, vol.34
, pp. 144-151
-
-
Noël, A.1
Aletti, P.2
Bey, P.3
Malissard, L.4
-
12
-
-
0021889491
-
Clinical experience with a computerized record and verify system
-
Podmaniczky, K.C., Mohan, R., Kutcher, G.J., Kestler, C. and Vikram, B. Clinical experience with a computerized record and verify system. Int. J. Radiat. Oncol. Biol. Phys. 11: 1529-1537, 1985.
-
(1985)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.11
, pp. 1529-1537
-
-
Podmaniczky, K.C.1
Mohan, R.2
Kutcher, G.J.3
Kestler, C.4
Vikram, B.5
-
13
-
-
0021979174
-
Dose evaluation to patients irradiated by Co60, by means of direct measurement on the incident and on the exit surfaces
-
Rizzotti, A., Compri, C. and Garusi, G. Dose evaluation to patients irradiated by Co60, by means of direct measurement on the incident and on the exit surfaces. Radiother. Oncol. 3: 279-283, 1985.
-
(1985)
Radiother. Oncol.
, vol.3
, pp. 279-283
-
-
Rizzotti, A.1
Compri, C.2
Garusi, G.3
-
14
-
-
0027968741
-
Evaluation of most frequent errors in daily compilation and use of a radiation treatment chart
-
Valli, M.C., Prina, P., Bossi, A. et al. Evaluation of most frequent errors in daily compilation and use of a radiation treatment chart. Radiother. Oncol. 32: 87-89, 1994.
-
(1994)
Radiother. Oncol.
, vol.32
, pp. 87-89
-
-
Valli, M.C.1
Prina, P.2
Bossi, A.3
|