Volumn 45, Issue 3, 1997, Pages 271-274

Detection of systematic errors in external radiotherapy before treatment delivery

Author keywords

Human errors; In vivo dosimetry; Monitor unit calculation; Quality assurance; Transfer errors

Indexed keywords

ANALYTICAL ERROR; ARTICLE; CONTROLLED STUDY; DOSE CALCULATION; HEALTH CARE DELIVERY; HUMAN; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; QUALITY CONTROL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; TREATMENT PLANNING;

EID: 0030831903     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(97)00095-9     Document Type: Article
Times cited : (49)

References (14)
  • 1
    • 0023184257 scopus 로고    scopus 로고
    • Quality Assurance in radiation therapy: systematic evaluation of errors during the treatment execution
    • Blanco, S., Lopez-Bote, M. and Desco, M. Quality Assurance in radiation therapy: systematic evaluation of errors during the treatment execution. Radiother. Oncol. 8: 256-261.
    • Radiother. Oncol. , vol.8 , pp. 256-261
    • Blanco, S.1    Lopez-Bote, M.2    Desco, M.3
  • 5
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40
    • Kutcher, G.J., Coia, L., Gillin, et al. Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40. Med. Phys. 21: 581-618, 1994.
    • (1994) Med. Phys. , vol.21 , pp. 581-618
    • Kutcher, G.J.1    Coia, L.2    Gillin et, al.3
  • 7
    • 0026563447 scopus 로고
    • Detection of systematic patient setup errors by portal film analysis
    • Lebesque, J.V., Bel, A., Bijhold, J. and Hart, A.A.M. Detection of systematic patient setup errors by portal film analysis. Radiother. Oncol. 23: 198, 1992.
    • (1992) Radiother. Oncol. , vol.23 , pp. 198
    • Lebesque, J.V.1    Bel, A.2    Bijhold, J.3    Hart, A.A.M.4
  • 8
    • 0025166575 scopus 로고
    • Quality assurance in radiotherapy by in-vivo dosimetry. 1. Entrance dose measurements, a reliable procedure
    • Leunens, G., van Dam, J., Dutreix, A. and van der Schueren, E. Quality assurance in radiotherapy by in-vivo dosimetry. 1. Entrance dose measurements, a reliable procedure. Radiother. Oncol. 17: 141-151, 1990.
    • (1990) Radiother. Oncol. , vol.17 , pp. 141-151
    • Leunens, G.1    Van Dam, J.2    Dutreix, A.3    Van Der Schueren, E.4
  • 9
    • 0026587135 scopus 로고
    • Human errors in data transfer during the preparation and delivery of radiation treatment affecting the final result: 'garbage in, garbage out'
    • Leunens, G., Verstrate, J., Van der Gogaert, W., Van Dam, J., Dutreix, A. and Van der Schueren, E. Human errors in data transfer during the preparation and delivery of radiation treatment affecting the final result: 'garbage in, garbage out'. Radiother. Oncol. 23: 217-222, 1992.
    • (1992) Radiother. Oncol. , vol.23 , pp. 217-222
    • Leunens, G.1    Verstrate, J.2    Van Der Gogaert, W.3    Van Dam, J.4    Dutreix, A.5    Van Der Schueren, E.6
  • 10
    • 0017133803 scopus 로고
    • The value of frequent verification films in reducing localization errors in the irradiation of complex fields
    • Marks, J.E., Haus, A.G., Sutton, H.G. and Griem, M.L. The value of frequent verification films in reducing localization errors in the irradiation of complex fields. Cancer 37: 2755-2761, 1976.
    • (1976) Cancer , vol.37 , pp. 2755-2761
    • Marks, J.E.1    Haus, A.G.2    Sutton, H.G.3    Griem, M.L.4
  • 11
    • 0028958815 scopus 로고
    • Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry
    • Noël, A., Aletti, P., Bey, P. and Malissard, L. Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry. Radiother. Oncol. 34: 144-151, 1995.
    • (1995) Radiother. Oncol. , vol.34 , pp. 144-151
    • Noël, A.1    Aletti, P.2    Bey, P.3    Malissard, L.4
  • 13
    • 0021979174 scopus 로고
    • Dose evaluation to patients irradiated by Co60, by means of direct measurement on the incident and on the exit surfaces
    • Rizzotti, A., Compri, C. and Garusi, G. Dose evaluation to patients irradiated by Co60, by means of direct measurement on the incident and on the exit surfaces. Radiother. Oncol. 3: 279-283, 1985.
    • (1985) Radiother. Oncol. , vol.3 , pp. 279-283
    • Rizzotti, A.1    Compri, C.2    Garusi, G.3
  • 14
    • 0027968741 scopus 로고
    • Evaluation of most frequent errors in daily compilation and use of a radiation treatment chart
    • Valli, M.C., Prina, P., Bossi, A. et al. Evaluation of most frequent errors in daily compilation and use of a radiation treatment chart. Radiother. Oncol. 32: 87-89, 1994.
    • (1994) Radiother. Oncol. , vol.32 , pp. 87-89
    • Valli, M.C.1    Prina, P.2    Bossi, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.