메뉴 건너뛰기




Volumn 23, Issue 8, 1997, Pages 1185-1194

Preliminary study in differential contrast echography

Author keywords

Contrast agents; Dual channel; Echography; Frequency response; Parametric imaging; Spectral response; Subtraction; Ultrasound imaging

Indexed keywords

COLOR IMAGE PROCESSING; COMPUTER APPLICATIONS; CONTRAST MEDIA; DOPPLER EFFECT; FREQUENCY RESPONSE; IMAGE RECONSTRUCTION; MEDICAL IMAGING; SIGNAL PROCESSING;

EID: 0030827934     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(97)00116-6     Document Type: Article
Times cited : (10)

References (36)
  • 1
    • 0025142480 scopus 로고
    • On the application of ultrasonic contrast agents for blood flowmetry and assessment of cardiac perfusion
    • Bleeker H, Shung K, Barnhart J. On the application of ultrasonic contrast agents for blood flowmetry and assessment of cardiac perfusion. J Ultrasound Med 1990;9:461-471.
    • (1990) J Ultrasound Med , vol.9 , pp. 461-471
    • Bleeker, H.1    Shung, K.2    Barnhart, J.3
  • 2
    • 0019780775 scopus 로고
    • Hybrid subtraction for improved arteriography
    • Brody WR. Hybrid subtraction for improved arteriography. Radiology 1981;141:828-831.
    • (1981) Radiology , vol.141 , pp. 828-831
    • Brody, W.R.1
  • 3
    • 0019450609 scopus 로고
    • A method for selective bone and soft tissue subtraction using scanned digital radiography
    • Brody WR, Butt G, Hall A, et al. A method for selective bone and soft tissue subtraction using scanned digital radiography. Med Phys 1981;8:353-357.
    • (1981) Med Phys , vol.8 , pp. 353-357
    • Brody, W.R.1    Butt, G.2    Hall, A.3
  • 4
    • 84944970377 scopus 로고
    • Intravenous arteriography using digital subtraction techniques
    • Brody WR, Enzmann DR, Miller DR, et al. Intravenous arteriography using digital subtraction techniques. JAMA 1982;248:671-674.
    • (1982) JAMA , vol.248 , pp. 671-674
    • Brody, W.R.1    Enzmann, D.R.2    Miller, D.R.3
  • 5
    • 0001281584 scopus 로고
    • Harmonic imaging: New imaging and Doppler method for contrast.Enhanced US
    • Burns PN, Powers JE, Fritzsch T. Harmonic imaging: New imaging and Doppler method for contrast.enhanced US. Radiology 1992;185(Suppl):142.
    • (1992) Radiology , vol.185 , Issue.SUPPL. , pp. 142
    • Burns, P.N.1    Powers, J.E.2    Fritzsch, T.3
  • 6
    • 0028749947 scopus 로고
    • Harmonic power mode Doppler using microbubble contrast agents: An improved method for small vessel flow imaging
    • Burns PN, Powers JE, Simpson DH, et al. Harmonic power mode Doppler using microbubble contrast agents: An improved method for small vessel flow imaging. IEEE Trans Biomed Eng 1994;3:1547-1550.
    • (1994) IEEE Trans Biomed Eng , vol.3 , pp. 1547-1550
    • Burns, P.N.1    Powers, J.E.2    Simpson, D.H.3
  • 10
    • 0022635541 scopus 로고
    • In vivo microbubble detection in decompression sickness using a second harmonic resonant bubble detector
    • Christman CL, Catron PW, Flynn ET, Weathersby PK. In vivo microbubble detection in decompression sickness using a second harmonic resonant bubble detector. Undersea Biomed Res 1986;13:1-18.
    • (1986) Undersea Biomed Res , vol.13 , pp. 1-18
    • Christman, C.L.1    Catron, P.W.2    Flynn, E.T.3    Weathersby, P.K.4
  • 11
    • 0019362845 scopus 로고
    • Digital video subtraction angiography for evaluation of peripheral vascular disease
    • Crummy AB, Strother CM, Liebermann RP, et al. Digital video subtraction angiography for evaluation of peripheral vascular disease. Radiology 1981;141:33-37.
    • (1981) Radiology , vol.141 , pp. 33-37
    • Crummy, A.B.1    Strother, C.M.2    Liebermann, R.P.3
  • 13
    • 0028549958 scopus 로고
    • Higher harmonics of vibrating gas-filled microspheres. Part one: Simulations
    • de Jong N, Cornet R, Lancée CT. Higher harmonics of vibrating gas-filled microspheres. Part one: simulations. Ultrasonics 1994a;32:447-453.
    • (1994) Ultrasonics , vol.32 , pp. 447-453
    • De Jong, N.1    Cornet, R.2    Lancée, C.T.3
  • 14
    • 0028550741 scopus 로고
    • Higher harmonics of vibrating gas-filled microspheres. Part two: Measurements
    • de Jong N, Cornet R, Lancée CT. Higher harmonics of vibrating gas-filled microspheres. Part two: measurements. Ultrasonics 1994b;32:455-459.
    • (1994) Ultrasonics , vol.32 , pp. 455-459
    • De Jong, N.1    Cornet, R.2    Lancée, C.T.3
  • 15
    • 0018844603 scopus 로고
    • Experimental dual xenon detectors for quantitative CT and spectral artifact correction
    • Drost DJ, Fenster A. Experimental dual xenon detectors for quantitative CT and spectral artifact correction. Med Phys 1980;7:101-107.
    • (1980) Med Phys , vol.7 , pp. 101-107
    • Drost, D.J.1    Fenster, A.2
  • 16
    • 0019953627 scopus 로고
    • Digital subtraction angiography: Overview of technical principles
    • Harrington DP, Boxt LM, Murray PD. Digital subtraction angiography: Overview of technical principles. AJR 1982;139:781-786.
    • (1982) AJR , vol.139 , pp. 781-786
    • Harrington, D.P.1    Boxt, L.M.2    Murray, P.D.3
  • 17
    • 84881114697 scopus 로고
    • Passive signal processing
    • Dorf RC, ed. Boca Raton, FL: CRC Press
    • Kerwin WJ. Passive signal processing. In: Dorf RC, ed. The electrical engineering handbook. Boca Raton, FL: CRC Press, 1993:111-125.
    • (1993) The Electrical Engineering Handbook , pp. 111-125
    • Kerwin, W.J.1
  • 18
    • 0029776016 scopus 로고    scopus 로고
    • Transmit aperture processing for non-linear contrast agent imaging
    • Krishnan S, O'Donnell M. Transmit aperture processing for non-linear contrast agent imaging. Ultrason Imaging 1996;18:77-105.
    • (1996) Ultrason Imaging , vol.18 , pp. 77-105
    • Krishnan, S.1    O'Donnell, M.2
  • 19
    • 0022577235 scopus 로고
    • Evaluation of frequency dependence of backscatter coefficient in normal and atherosclerotic aortic walls
    • Landini L, Sarnelli R, Picano E, Salvador M. Evaluation of frequency dependence of backscatter coefficient in normal and atherosclerotic aortic walls. Ultrasound Med Biol 1986;12:397-401.
    • (1986) Ultrasound Med Biol , vol.12 , pp. 397-401
    • Landini, L.1    Sarnelli, R.2    Picano, E.3    Salvador, M.4
  • 20
    • 0021491667 scopus 로고
    • Method of data reduction for accurate determination of acoustic backscatter coefficients
    • Madsen EL, Insana MF, Zagzebski JA. Method of data reduction for accurate determination of acoustic backscatter coefficients. J Acoust Soc Am 1984;76:913-923.
    • (1984) J Acoust Soc Am , vol.76 , pp. 913-923
    • Madsen, E.L.1    Insana, M.F.2    Zagzebski, J.A.3
  • 21
    • 0019208734 scopus 로고
    • Digital subtraction angiography of the human cardiovascular system
    • Meany TF, Weinstein MA, Buonocore E, et al. Digital subtraction angiography of the human cardiovascular system. AJR 1980; 135:1153-1160.
    • (1980) AJR , vol.135 , pp. 1153-1160
    • Meany, T.F.1    Weinstein, M.A.2    Buonocore, E.3
  • 22
    • 0019612103 scopus 로고
    • Ultrasonic detection of resonant cavitation bubbles in a flow tube by their second-harmonic emissions
    • Miller DL. Ultrasonic detection of resonant cavitation bubbles in a flow tube by their second-harmonic emissions. Ultrasonics 1981;19:217-224.
    • (1981) Ultrasonics , vol.19 , pp. 217-224
    • Miller, D.L.1
  • 23
    • 0020902352 scopus 로고
    • Myocardial tissue characterization: An approach based on quantitative backscatter and attenuation
    • Miller JG, Perez JE, Mottley JG, et al. Myocardial tissue characterization: An approach based on quantitative backscatter and attenuation. Proc IEEE Ultrason Symp 1983:782-793.
    • (1983) Proc IEEE Ultrason Symp , pp. 782-793
    • Miller, J.G.1    Perez, J.E.2    Mottley, J.G.3
  • 24
    • 0011153567 scopus 로고
    • Detection of myocardial contrast using backscatter spectral frequency analysis
    • Monaghan MJ, Metcalfe JM, Baker JH, Jewitt DE. Detection of myocardial contrast using backscatter spectral frequency analysis. Eur Heart J 1990a;11:113.
    • (1990) Eur Heart J , vol.11 , pp. 113
    • Monaghan, M.J.1    Metcalfe, J.M.2    Baker, J.H.3    Jewitt, D.E.4
  • 26
    • 0026042932 scopus 로고
    • Myocardial contrast echocardiography: Applications of digital ultrasound data acquisition and processing
    • Monaghan MJ, Metcalfe JM, Odunlami S, Jewitt DE. Myocardial contrast echocardiography: Applications of digital ultrasound data acquisition and processing. Am J Card Imaging 1991; 5:237-249.
    • (1991) Am J Card Imaging , vol.5 , pp. 237-249
    • Monaghan, M.J.1    Metcalfe, J.M.2    Odunlami, S.3    Jewitt, D.E.4
  • 27
    • 0027441881 scopus 로고
    • Digital radiofrequency echocardiography in the detection of myocardial contrast following intravenous administration of Albunex
    • Monaghan MJ, Metcalfe JM, Odunlami S, Waaler A, Jewitt DE. Digital radiofrequency echocardiography in the detection of myocardial contrast following intravenous administration of Albunex. Eur Heart J 1993;14:1200-1209.
    • (1993) Eur Heart J , vol.14 , pp. 1200-1209
    • Monaghan, M.J.1    Metcalfe, J.M.2    Odunlami, S.3    Waaler, A.4    Jewitt, D.E.5
  • 28
    • 0024409983 scopus 로고
    • Contrast agents in diagnostic ultrasound
    • Ophir J, Parker KJ. Contrast agents in diagnostic ultrasound. Ultrasound Med Biol 1989;15:319-333.
    • (1989) Ultrasound Med Biol , vol.15 , pp. 319-333
    • Ophir, J.1    Parker, K.J.2
  • 29
    • 0018858655 scopus 로고
    • Split-filter computed tomography: A simple technique for dual energy scanning
    • Rutt B, Fenster A. Split-filter computed tomography: A simple technique for dual energy scanning. J Comput Assist Tomogr 1980;4:501-509.
    • (1980) J Comput Assist Tomogr , vol.4 , pp. 501-509
    • Rutt, B.1    Fenster, A.2
  • 30
    • 0029116608 scopus 로고
    • BRI: A new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles
    • Schneider M, Arditi M, Brochot JA et al. BRI: A new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles. Invest Radiol 1995;30:451-457.
    • (1995) Invest Radiol , vol.30 , pp. 451-457
    • Schneider, M.1    Arditi, M.2    Brochot, J.A.3
  • 32
    • 0026535688 scopus 로고
    • Simulated capillary blood flow measurement using a non-linear ultrasonic contrast agent
    • Shrope B, Newhouse VL, Uhlendorf V. Simulated capillary blood flow measurement using a non-linear ultrasonic contrast agent. Ultrason Imaging 1992;14:134-158.
    • (1992) Ultrason Imaging , vol.14 , pp. 134-158
    • Shrope, B.1    Newhouse, V.L.2    Uhlendorf, V.3
  • 33
    • 0027496845 scopus 로고
    • Second harmonic blood perfusion measurement
    • Shrope B, Newhouse VL. Second harmonic blood perfusion measurement. Ultrasound Med Biol 1993;19:567-579.
    • (1993) Ultrasound Med Biol , vol.19 , pp. 567-579
    • Shrope, B.1    Newhouse, V.L.2
  • 35
    • 0015625563 scopus 로고
    • Analysis and measurement of ultrasound backscattering from an ensemble of scatterers excited by sinewave bursts
    • Sigelmann RA, Reid JM. Analysis and measurement of ultrasound backscattering from an ensemble of scatterers excited by sinewave bursts. J Acoust Soc Am 1973;53:1351-1355.
    • (1973) J Acoust Soc Am , vol.53 , pp. 1351-1355
    • Sigelmann, R.A.1    Reid, J.M.2
  • 36
    • 0026005354 scopus 로고
    • Left ventricular dual-energy digital subtraction angiography: A motion immune digital subtraction technique
    • van Lysel MS, Miller WP, Senior DG, et al. Left ventricular dual-energy digital subtraction angiography: A motion immune digital subtraction technique. Int J Card Imaging 1991;7:55-65.
    • (1991) Int J Card Imaging , vol.7 , pp. 55-65
    • Van Lysel, M.S.1    Miller, W.P.2    Senior, D.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.