메뉴 건너뛰기




Volumn 24, Issue 9, 1997, Pages 1515-1519

Measuring dose distributions for enhanced dynamic wedges using a multichamber detector array

Author keywords

Chamber detector array; Enhanced dynamic wedge; Radiographic films

Indexed keywords

DETECTOR ARRAYS; DOSE DISTRIBUTIONS; DOSE MEASUREMENT; ENHANCED DYNAMIC WEDGES; MEASUREMENT PARAMETERS; RADIOGRAPHIC FILMS; SINGLE CHAMBERS; TECHNICAL ASPECTS;

EID: 0030823126     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598040     Document Type: Article
Times cited : (15)

References (8)
  • 1
    • 0018134649 scopus 로고
    • Wedge-shaped dose distributions by computer-controlled collimator motion
    • P. K. Kijewski, L. M. Chin, and B. E. Bjarngard, "Wedge-shaped dose distributions by computer-controlled collimator motion," Med. Phys. 5, 426-429 (1978).
    • (1978) Med. Phys. , vol.5 , pp. 426-429
    • Kijewski, P.K.1    Chin, L.M.2    Bjarngard, B.E.3
  • 2
    • 0025177031 scopus 로고
    • Dynamic wedge field techniques through computer-controlled collimator motion and dose delivery
    • D. D. Leavitt, M Martin, J. H. Moeller, and W. L. Lee, "Dynamic wedge field techniques through computer-controlled collimator motion and dose delivery," Med. Phys. 17, 87-91 (1991).
    • (1991) Med. Phys. , vol.17 , pp. 87-91
    • Leavitt, D.D.1    Martin, M.2    Moeller, J.H.3    Lee, W.L.4
  • 3
    • 0027155246 scopus 로고
    • Evaluation of a diode detector array for measurement of dynamic wedge dose distributions
    • D. D. Leavitt and L. Larsson, "Evaluation of a diode detector array for measurement of dynamic wedge dose distributions," Med. Phys. 20, 381-382 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 381-382
    • Leavitt, D.D.1    Larsson, L.2
  • 4
    • 0028930359 scopus 로고
    • Beam data measurements for dynamic wedges on Varian 500C (6 MV) and 2100C (6 and 10 MV) linear accelerators
    • A. M. Bidmead, A. J Garton, and P. J. Childs, "Beam data measurements for dynamic wedges on Varian 500C (6 MV) and 2100C (6 and 10 MV) linear accelerators," Phys. Med. Biol. 40, 393-411 (1995).
    • (1995) Phys. Med. Biol. , vol.40 , pp. 393-411
    • Bidmead, A.M.1    Garton, A.J.2    Childs, P.J.3
  • 6
    • 0028940352 scopus 로고
    • An investigation into the comparison between different dosimetric methods of measuring profiles and depth doses for dynamic wedges on a Varian 600C linear accelerator
    • P. Elder, F. Coveney, and A. D. Welsh, "An investigation into the comparison between different dosimetric methods of measuring profiles and depth doses for dynamic wedges on a Varian 600C linear accelerator," Phys. Med Biol 40, 683-689 (1995).
    • (1995) Phys. Med Biol , vol.40 , pp. 683-689
    • Elder, P.1    Coveney, F.2    Welsh, A.D.3
  • 7
    • 0029840312 scopus 로고    scopus 로고
    • Implementation of the Varian EDW into a commercial RTP system
    • A. W. Beavis, S. J. Weston, and V. J Whitton, "Implementation of the Varian EDW into a commercial RTP system," Phys. Med. Biol. 41, 1691-1704 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1691-1704
    • Beavis, A.W.1    Weston, S.J.2    Whitton, V.J.3
  • 8
    • 0019504287 scopus 로고
    • Film density of megavoltage photon beams: A practical method of isodensity-to-isodose curve conversion
    • J. F. Williamson, F. M. Khan, and S. C. Sharma, "Film density of megavoltage photon beams: A practical method of isodensity-to-isodose curve conversion," Med. Phys. 8, 94-98 (1981).
    • (1981) Med. Phys. , vol.8 , pp. 94-98
    • Williamson, J.F.1    Khan, F.M.2    Sharma, S.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.