메뉴 건너뛰기




Volumn 39, Issue 1, 1997, Pages 247-254

Clinical treatment planning optimization by Powell's method for gamma unit treatment system

Author keywords

3D treatment planning; Nonlinear programming; Stereotactic radiosurgery

Indexed keywords

COBALT 60;

EID: 0030821929     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(97)00305-2     Document Type: Article
Times cited : (16)

References (14)
  • 4
    • 0028839218 scopus 로고
    • Treatment planning optimization for multiple arcs stereotactic radiosurgery using a linear accelerator
    • Lam, C. F.; Zhu, J. G.; Fenn, J. O.; Jenrette, J. M. Treatment planning optimization for multiple arcs stereotactic radiosurgery using a linear accelerator. Int. J. Radiat. Oncol. Biol. Phys. 33:647-657; 1995.
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.33 , pp. 647-657
    • Lam, C.F.1    Zhu, J.G.2    Fenn, J.O.3    Jenrette, J.M.4
  • 5
    • 0026969381 scopus 로고
    • Investigating the potential of three-dimensional treatment planning
    • Fraass, B. A. Investigating the potential of three-dimensional treatment planning. Med. Prog. Technol. 18:227-238; 1993.
    • (1993) Med. Prog. Technol. , vol.18 , pp. 227-238
    • Fraass, B.A.1
  • 6
  • 7
    • 0025995744 scopus 로고
    • Treatment planning for stereotactic radiosurgery of intracranial lesions
    • Kooy, H. M. Treatment planning for stereotactic radiosurgery of intracranial lesions, Int. J. Radiat. Oncol. Biol. Phys. 21:683-693; 1991.
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.21 , pp. 683-693
    • Kooy, H.M.1
  • 9
    • 0028147744 scopus 로고
    • Voxel-based localization in frame-based and frameless stereotaxy and its accuracy
    • Lemieux, L. Voxel-based localization in frame-based and frameless stereotaxy and its accuracy. Med. Phys. 21:1303-1310; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 1303-1310
    • Lemieux, L.1
  • 10
    • 0024492354 scopus 로고
    • Stereotactic radiosurgery of the brain using the first United States 201 cobalt 60 source gamma knife
    • Lunsford, L. D.; Flickinger, J. C.; Lindner, G.; Maintz, A. Stereotactic radiosurgery of the brain using the first United States 201 cobalt 60 source gamma knife. Neurosurgery 24:151-159; 1989.
    • (1989) Neurosurgery , vol.24 , pp. 151-159
    • Lunsford, L.D.1    Flickinger, J.C.2    Lindner, G.3    Maintz, A.4
  • 13
    • 0001008029 scopus 로고
    • An efficient method for finding the minimum of a function of several variables without calculating derivatives
    • Powell, M. J. D. An efficient method for finding the minimum of a function of several variables without calculating derivatives. Comput. J. 7:896-910; 1964.
    • (1964) Comput. J. , vol.7 , pp. 896-910
    • Powell, M.J.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.