-
2
-
-
0031190265
-
Energy loss measurements of 27 MeV protons irradiating water-equivalent materials
-
Torrisi L, Cuttone G, Rovelli A, Bellia G, Barone Tonghi L, Raffaele L and Licandro M. Energy loss measurements of 27 MeV protons irradiating water-equivalent materials, NIM B 1997: 129(2); 147-152.
-
(1997)
NIM B
, vol.129
, Issue.2
, pp. 147-152
-
-
Torrisi, L.1
Cuttone, G.2
Rovelli, A.3
Bellia, G.4
Barone Tonghi, L.5
Raffaele, L.6
Licandro, M.7
-
3
-
-
0026804696
-
Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
-
Beddar AS, Mackie TR and Attix FH. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations. Phys Med Biol 1992: 37(10); 1883-1900.
-
(1992)
Phys Med Biol
, vol.37
, Issue.10
, pp. 1883-1900
-
-
Beddar, A.S.1
Mackie, T.R.2
Attix, F.H.3
-
4
-
-
12644260227
-
-
Catalogue Nuclear Associated-Division Victoreen Plastic Water PM Phantom New York
-
Catalogue Nuclear Associated-Division Victoreen Plastic Water PM Phantom New York 1994/95, Radiation Therapy Cat. T-3/41.
-
(1994)
Radiation Therapy Cat. T-3/41
-
-
-
5
-
-
0003682469
-
Tissue substitutes in radiation dosimetry and measurements
-
ICRU Report 44
-
ICRU Report 44. Tissue substitutes in radiation dosimetry and measurements. Int Comm on Rad Units and Meas Maryland 1989.
-
(1989)
Int Comm on Rad Units and Meas Maryland
-
-
-
6
-
-
12644313925
-
Material Division. Scintillation materials
-
NE-Technology. Princeton Corp Plaza NJ
-
NE-Technology. Material Division. Scintillation materials. General Cathalog of Scintillators. Princeton Corp Plaza NJ 1995.
-
(1995)
General Cathalog of Scintillators
-
-
-
8
-
-
0027938389
-
The calibration and use of plane-parallel chambers for dosimetry of electron beams: An extension of the 1983 AAPM protocol report of AAPM radiation therapy committee task group n° 39
-
Almond PR, Attix FH, Humphries LJ, Kubo H, Nath R, Geotsch S and Rogers DW. The calibration and use of plane-parallel chambers for dosimetry of electron beams: an extension of the 1983 AAPM protocol report of AAPM radiation therapy committee task group n° 39. Med Phys 1994: 21(8); 1251-1262.
-
(1994)
Med Phys
, vol.21
, Issue.8
, pp. 1251-1262
-
-
Almond, P.R.1
Attix, F.H.2
Humphries, L.J.3
Kubo, H.4
Nath, R.5
Geotsch, S.6
Rogers, D.W.7
-
10
-
-
0003697463
-
Stopping power and ranges for protons and alpha paticles
-
ICRU Report 49.
-
ICRU Report 49. Stopping power and ranges for protons and alpha paticles. Int Comm on Rad Units and Meas Maryland 1993.
-
(1993)
Int Comm on Rad Units and Meas Maryland
-
-
-
11
-
-
0002164727
-
Particle data Group
-
Aguilar-Benitez M et al. Particle data Group. Phys Lett 1986: 170 (B); 45-58.
-
(1986)
Phys Lett
, vol.170
, Issue.B
, pp. 45-58
-
-
Aguilar-Benitez, M.1
-
12
-
-
0017012292
-
Responce of plastic scintillator detectors to heavy ions, Z<35, E<170 MeV
-
Becchetti FD, Thorn CE and Levine MJ. Responce of plastic scintillator detectors to heavy ions, Z<35, E<170 MeV. Nucl Instr and Methods 1976: 138; 93-104.
-
(1976)
Nucl Instr and Methods
, vol.138
, pp. 93-104
-
-
Becchetti, F.D.1
Thorn, C.E.2
Levine, M.J.3
-
13
-
-
0029070189
-
Ionization chamber dosimetry of proton beams using cylindrical and plane parallel chambers. Nw versus Nk ion chamber calibration
-
Medin J, Andreo P, Grusell E, Mattsson O, Montelius A and Roos M. Ionization chamber dosimetry of proton beams using cylindrical and plane parallel chambers. Nw versus Nk ion chamber calibration. Phy Med Biol 1995: 40; 1161-1176.
-
(1995)
Phy Med Biol
, vol.40
, pp. 1161-1176
-
-
Medin, J.1
Andreo, P.2
Grusell, E.3
Mattsson, O.4
Montelius, A.5
Roos, M.6
|