메뉴 건너뛰기




Volumn 20, Issue 8, 1997, Pages 436-439

Laser profiling of bovine pericardial heart valves

Author keywords

Heart valve function; Heart valve prosthesis; Laser profiling

Indexed keywords

HEART;

EID: 0030820104     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.1177/039139889702000805     Document Type: Article
Times cited : (1)

References (9)
  • 1
    • 0020660663 scopus 로고
    • Long-term failure rate and morphologic correlations in porcrine bioprosthetic heart valves
    • Schoen FJ, Collins JJ, Cohn LH. Long-term failure rate and morphologic correlations in porcrine bioprosthetic heart valves. Am J Cardiol 1983 51:957-64.
    • (1983) Am J Cardiol , vol.51 , pp. 957-964
    • Schoen, F.J.1    Collins, J.J.2    Cohn, L.H.3
  • 2
    • 0021888534 scopus 로고
    • Valve failure with the lonescu-Shiley bovine pericardial bioprosthesis: Analysis of 2680 patients
    • Reul GJ, Cooley DA, Duncan JM, et al. Valve failure with the lonescu-Shiley bovine pericardial bioprosthesis: analysis of 2680 patients. J Vasc Surg 1985; 2:192-204.
    • (1985) J Vasc Surg , vol.2 , pp. 192-204
    • Reul, G.J.1    Cooley, D.A.2    Duncan, J.M.3
  • 3
    • 0022623739 scopus 로고
    • Comparative study of primary tissue failure between lonescu-Shiley pericardial and Hancock porcine valves in the aortic position
    • Nistal F, Garcia-Satué E, Artiñano E, Durán CMG, Gallo I. Comparative study of primary tissue failure between lonescu-Shiley pericardial and Hancock porcine valves in the aortic position. Am J Cardiol 1986; 57:161-4.
    • (1986) Am J Cardiol , vol.57 , pp. 161-164
    • Nistal, F.1    Garcia-Satué, E.2    Artiñano, E.3    Durán, C.M.G.4    Gallo, I.5
  • 5
    • 0026911796 scopus 로고
    • In vitro calcification of bioprosthetic heart valves: Report of a novel method and review of the biochemical factors involved
    • Bernacca GM, Mackay TG, Wheatley DJ. In vitro calcification of bioprosthetic heart valves: report of a novel method and review of the biochemical factors involved. J Heart Valve Dis 1992; 1:115-30.
    • (1992) J Heart Valve Dis , vol.1 , pp. 115-130
    • Bernacca, G.M.1    Mackay, T.G.2    Wheatley, D.J.3
  • 6
    • 0025113785 scopus 로고
    • A two dimensional finite element analysis of a bioprosthetic heart valve
    • Huang X, Black MM, Howard IC, Patterson EA. A two dimensional finite element analysis of a bioprosthetic heart valve. J Biomech 1990; 23: 753-62.
    • (1990) J Biomech , vol.23 , pp. 753-762
    • Huang, X.1    Black, M.M.2    Howard, I.C.3    Patterson, E.A.4
  • 7
    • 0027642707 scopus 로고
    • Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents
    • Krucinski S, Vesely I, Dokainish MA, Cambell G. Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents. J Biomech 1993; 26: 929-43.
    • (1993) J Biomech , vol.26 , pp. 929-943
    • Krucinski, S.1    Vesely, I.2    Dokainish, M.A.3    Cambell, G.4
  • 8
    • 0023755406 scopus 로고
    • Tissue buckling as a mechanism of bioprosthetic valve failure
    • Vesely I, Boughner DR, Song T. Tissue buckling as a mechanism of bioprosthetic valve failure. Ann Thorac Surg 1988; 46:302-8.
    • (1988) Ann Thorac Surg , vol.46 , pp. 302-308
    • Vesely, I.1    Boughner, D.R.2    Song, T.3
  • 9
    • 0029057095 scopus 로고
    • Laser profiling: A technique for the study of prosthetic heart valve failure. Physiol study of prosthetic heart valve failure
    • Fenner JW, Mackay TG, Martin W, Wheatley DJ. Laser profiling: a technique for the study of prosthetic heart valve failure. Physiol study of prosthetic heart valve failure. Physiol Meas 1995; 16:181-93.
    • (1995) Physiol Meas , vol.16 , pp. 181-193
    • Fenner, J.W.1    Mackay, T.G.2    Martin, W.3    Wheatley, D.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.