-
7
-
-
0017879929
-
An optimized collimator for single-photon computed tomography with scintillation camera
-
Kircos LT, Leonard PF, Keyes JW. An optimized collimator for single-photon computed tomography with scintillation camera. J Nucl Med 1978;19:322-3.
-
(1978)
J Nucl Med
, vol.19
, pp. 322-323
-
-
Kircos, L.T.1
Leonard, P.F.2
Keyes, J.W.3
-
8
-
-
0023038132
-
Collimator selection for SPECT brain imaging: The advantage of high resolution
-
Mueller SP, Polak JF, Kijewski MF, Holman BL. Collimator selection for SPECT brain imaging: the advantage of high resolution. J Nucl Med 1986;27:1729-38.
-
(1986)
J Nucl Med
, vol.27
, pp. 1729-1738
-
-
Mueller, S.P.1
Polak, J.F.2
Kijewski, M.F.3
Holman, B.L.4
-
9
-
-
0026636942
-
Scatter, spatial resolution, and quantitative recovery in high resolution SPECT
-
Szabo Z, Links JM, Seki C, Rhine J, Wagner HN Jr. Scatter, spatial resolution, and quantitative recovery in high resolution SPECT. J Comput Assist Tomogr 1992;16:461-7.
-
(1992)
J Comput Assist Tomogr
, vol.16
, pp. 461-467
-
-
Szabo, Z.1
Links, J.M.2
Seki, C.3
Rhine, J.4
Wagner Jr., H.N.5
-
10
-
-
0029782581
-
Collimator design for improved spatial resolution in SPECT and planar scintigraphy
-
Kimiaei S, Larsson SA, Jacobsson H. Collimator design for improved spatial resolution in SPECT and planar scintigraphy. J Nucl Med 1996;37:1417-21.
-
(1996)
J Nucl Med
, vol.37
, pp. 1417-1421
-
-
Kimiaei, S.1
Larsson, S.A.2
Jacobsson, H.3
-
11
-
-
0028943771
-
Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee
-
Graham LS, Fahey FH, Madsen MT, van Aswegen A, Yester MV. Quantitation of SPECT performance: report of Task Group 4, Nuclear Medicine Committee. Med Phys 1995;22:401-9.
-
(1995)
Med Phys
, vol.22
, pp. 401-409
-
-
Graham, L.S.1
Fahey, F.H.2
Madsen, M.T.3
Van Aswegen, A.4
Yester, M.V.5
-
12
-
-
0028197451
-
Myocardial perfusion imaging using single-photon emission computed tomography
-
Garvin AA, Cullom SJ, Garcia EV. Myocardial perfusion imaging using single-photon emission computed tomography [review]. Am J Card Imaging 1994;8:189-98.
-
(1994)
Am J Card Imaging
, vol.8
, pp. 189-198
-
-
Garvin, A.A.1
Cullom, S.J.2
Garcia, E.V.3
-
13
-
-
0026706838
-
Sensitivity, resolution and image quality with a multi-head SPECT camera
-
Fahey FH, Harkness BA, Keyes JW Jr, Madsen MT, Battisti C, Zito V. Sensitivity, resolution and image quality with a multi-head SPECT camera. J Nucl Med 1992;33:1859-63.
-
(1992)
J Nucl Med
, vol.33
, pp. 1859-1863
-
-
Fahey, F.H.1
Harkness, B.A.2
Keyes Jr., J.W.3
Madsen, M.T.4
Battisti, C.5
Zito, V.6
-
14
-
-
0015911128
-
Computerized transverse axial scanning (tomography). Part 1: Description of system
-
Hounsfield GN. Computerized transverse axial scanning (tomography). Part 1: description of system. Br J Radiol 1973;56:1016-22.
-
(1973)
Br J Radiol
, vol.56
, pp. 1016-1022
-
-
Hounsfield, G.N.1
-
15
-
-
0001069532
-
Representation of a function by its line integrals with some radiological applications
-
Cormack AM. Representation of a function by its line integrals with some radiological applications. J Appl Phys 1963;3:2722-7.
-
(1963)
J Appl Phys
, vol.3
, pp. 2722-2727
-
-
Cormack, A.M.1
-
16
-
-
12544260746
-
Representation of a function by its line integrals with some radiological applications. II
-
Cormack AM. Representation of a function by its line integrals with some radiological applications. II. J Appl Phys 19964;35:2908-13.
-
(1996)
J Appl Phys
, vol.4
, Issue.35
, pp. 2908-2913
-
-
Cormack, A.M.1
-
21
-
-
0017328286
-
Noise due to photon counting statistics in computer x-ray tomography
-
Chesler DA, Riederer SJ, Pele NJ. Noise due to photon counting statistics in computer x-ray tomography. J Comput Assist Tomogr 1977;1:64-74.
-
(1977)
J Comput Assist Tomogr
, vol.1
, pp. 64-74
-
-
Chesler, D.A.1
Riederer, S.J.2
Pele, N.J.3
-
22
-
-
0017453285
-
The characteristics of computed tomographic reconstruction noise and their effect on detectability
-
Hanson KM, Boyd DP. The characteristics of computed tomographic reconstruction noise and their effect on detectability. IEEE Trans Nucl Sci 1978;25:160.
-
(1978)
IEEE Trans Nucl Sci
, vol.25
, pp. 160
-
-
Hanson, K.M.1
Boyd, D.P.2
-
23
-
-
12644255667
-
Application of the Budinger equation to evaluate signal to noise ratios of single photon emission tomographic systems
-
MacIntyre WJ, et al. Application of the Budinger equation to evaluate signal to noise ratios of single photon emission tomographic systems (abstract). J Nucl Med 1983;24:75.
-
(1983)
J Nucl Med
, vol.24
, pp. 75
-
-
MacIntyre, W.J.1
-
24
-
-
0020193284
-
Estimation of the local statistical noise in emission computed tomography
-
Alpert NM, Cheslern DA, Correia JA, Ackerman RH, Chang JY, Finkelstein S, et al. Estimation of the local statistical noise in emission computed tomography. IEEE Trans Med Imag 1982;MI-1:142-6.
-
(1982)
IEEE Trans Med Imag
, vol.MI-1
, pp. 142-146
-
-
Alpert, N.M.1
Cheslern, D.A.2
Correia, J.A.3
Ackerman, R.H.4
Chang, J.Y.5
Finkelstein, S.6
-
25
-
-
0026065508
-
Spatial resolution in SPECT: Influence of measurement set-up and reconstruction parameters
-
Geworski L, Jordan K. Spatial resolution in SPECT: influence of measurement set-up and reconstruction parameters. Nuklearmedizin 1991;30:24-30.
-
(1991)
Nuklearmedizin
, vol.30
, pp. 24-30
-
-
Geworski, L.1
Jordan, K.2
-
26
-
-
12644261390
-
Filtering for image reconstruction from projections
-
Baba N, Murata K. Filtering for image reconstruction from projections. J Optic Soc Am 1977;67:662-8.
-
(1977)
J Optic Soc Am
, vol.67
, pp. 662-668
-
-
Baba, N.1
Murata, K.2
-
27
-
-
0024411539
-
A unified design algorithm of two-dimensional digital filters for radioisotope image processing
-
Murase K, Ishine M, Kawamura, Tanada MS, Iio A, Hamamoto K. A unified design algorithm of two-dimensional digital filters for radioisotope image processing. Phys Med Biol 1989;34:859-73.
-
(1989)
Phys Med Biol
, vol.34
, pp. 859-873
-
-
Murase, K.1
Ishine, M.2
Kawamura3
Tanada, M.S.4
Iio, A.5
Hamamoto, K.6
-
28
-
-
0016068330
-
The Fourier reconstruction of a head section
-
Shepp LA, Logan BF. The Fourier reconstruction of a head section. IEEE Trans Nucl Sci 1974;MS-21:21-43.
-
(1974)
IEEE Trans Nucl Sci
, vol.MS-21
, pp. 21-43
-
-
Shepp, L.A.1
Logan, B.F.2
-
29
-
-
0004181307
-
-
Englewood Cliffs, N.J.: Prentice-Hall
-
Hamming RW. Digital filters. Englewood Cliffs, N.J.: Prentice-Hall, 1977.
-
(1977)
Digital Filters
-
-
Hamming, R.W.1
-
30
-
-
0015954210
-
Quantitative effects of stationary linear image processing on nose and resolution of structure in radionuclide images
-
Metz CE, Beck RN. Quantitative effects of stationary linear image processing on nose and resolution of structure in radionuclide images. J Nucl Med 1974;15:164.
-
(1974)
J Nucl Med
, vol.15
, pp. 164
-
-
Metz, C.E.1
Beck, R.N.2
-
31
-
-
0022884285
-
Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters
-
King MA, Schwinger RB, Penney BC, Doherty PW, Bianco JA. Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters. J Nucl Med 1986;27:1327-36.
-
(1986)
J Nucl Med
, vol.27
, pp. 1327-1336
-
-
King, M.A.1
Schwinger, R.B.2
Penney, B.C.3
Doherty, P.W.4
Bianco, J.A.5
-
32
-
-
0022577331
-
Variation of the countdependent Metz filter with imaging system modulation transfer function
-
King MA, Schwinger RB, Penney BC. Variation of the countdependent Metz filter with imaging system modulation transfer function. Med Phys 1986;13:139-49.
-
(1986)
Med Phys
, vol.13
, pp. 139-149
-
-
King, M.A.1
Schwinger, R.B.2
Penney, B.C.3
-
33
-
-
0023205171
-
Interactive visual optimization of SPECT prereconstruction filtering
-
King MA, Glick SJ, Penney BC, Schwinger RB, Doherty PW. Interactive visual optimization of SPECT prereconstruction filtering. J Nucl Med 1987;28:1192-8.
-
(1987)
J Nucl Med
, vol.28
, pp. 1192-1198
-
-
King, M.A.1
Glick, S.J.2
Penney, B.C.3
Schwinger, R.B.4
Doherty, P.W.5
-
34
-
-
0025752507
-
Activity quantitation in SPECT: A study of prereconstruction Metz filtering and use of the scatter degradation factor
-
King MA, Coleman M, Penney BC, Glick SJ. Activity quantitation in SPECT: a study of prereconstruction Metz filtering and use of the scatter degradation factor. Med Phys 1991;18:184-9.
-
(1991)
Med Phys
, vol.18
, pp. 184-189
-
-
King, M.A.1
Coleman, M.2
Penney, B.C.3
Glick, S.J.4
-
35
-
-
0025292379
-
Wiener filtering improves quantification of regional myocardial perfusion with thallium-201 SPECT
-
Links JM, Jeremy RW, Dyer SM, Frank TL, Becker LC. Wiener filtering improves quantification of regional myocardial perfusion with thallium-201 SPECT. J Nucl Med 1990;31:1230-6.
-
(1990)
J Nucl Med
, vol.31
, pp. 1230-1236
-
-
Links, J.M.1
Jeremy, R.W.2
Dyer, S.M.3
Frank, T.L.4
Becker, L.C.5
-
36
-
-
0023474034
-
Optimal preprocessing Butterworth-Wiener filter for Tl-201 myocardial SPECT
-
Honda N, Machida K, Tsukada J, Kaizu H, Hosoba M. Optimal preprocessing Butterworth-Wiener filter for Tl-201 myocardial SPECT. Eur J Nucl Med 1987;13:404-7.
-
(1987)
Eur J Nucl Med
, vol.13
, pp. 404-407
-
-
Honda, N.1
Machida, K.2
Tsukada, J.3
Kaizu, H.4
Hosoba, M.5
-
37
-
-
0027247362
-
Optimization of Butterworth filter for brain SPECT imaging
-
Minoshima S, Maruno H, Yui N, Togawa T, Kinoshita F, Kubota M, et al. Optimization of Butterworth filter for brain SPECT imaging. Ann Nucl Med 1993;7:71-7.
-
(1993)
Ann Nucl Med
, vol.7
, pp. 71-77
-
-
Minoshima, S.1
Maruno, H.2
Yui, N.3
Togawa, T.4
Kinoshita, F.5
Kubota, M.6
-
38
-
-
0023932063
-
Determination of the optimum filter function for SPECT imaging
-
Gilland DR, Tsui BM, McCartney WH, Perry JR, Berg J. Determination of the optimum filter function for SPECT imaging. J Nucl Med 1988;29:643-50.
-
(1988)
J Nucl Med
, vol.29
, pp. 643-650
-
-
Gilland, D.R.1
Tsui, B.M.2
McCartney, W.H.3
Perry, J.R.4
Berg, J.5
-
39
-
-
0016164145
-
Three-dimensional reconstruction from projections: A review of algorithms
-
Gordon R, Herman GT. Three-dimensional reconstruction from projections: a review of algorithms. Int Rev Cytol 1971;38:111-51.
-
(1971)
Int Rev Cytol
, vol.38
, pp. 111-151
-
-
Gordon, R.1
Herman, G.T.2
|