메뉴 건너뛰기




Volumn 12, Issue 8, 1997, Pages 1689-1691

Central venous catheters for haemodialysis: Looking for optimal blood flow

Author keywords

Blood flow; Catheter; Haemodialysis; Right atrium; Venous pressure

Indexed keywords

SILICONE;

EID: 0030795624     PISSN: 09310509     EISSN: None     Source Type: Journal    
DOI: 10.1093/ndt/12.8.1689     Document Type: Article
Times cited : (49)

References (9)
  • 1
    • 0025240760 scopus 로고
    • The use of a dual lumen jugular venous catheters as a definitive long term access for hemodialysis
    • Blake PG, Huraib S, Wu G, Uldall PR. The use of a dual lumen jugular venous catheters as a definitive long term access for hemodialysis. Int J Artif Organs 1990; 13(1): 26-31
    • (1990) Int J Artif Organs , vol.13 , Issue.1 , pp. 26-31
    • Blake, P.G.1    Huraib, S.2    Wu, G.3    Uldall, P.R.4
  • 2
    • 0022492675 scopus 로고
    • La canulation jugulaire interne avec deux cathéters silastic. Une nouvelle méthode d'accés vasculaire pour hémodialyse
    • Canaud B, Saunier F, Beraud JJ, Joyeux H, Mion C. La canulation jugulaire interne avec deux cathéters silastic. Une nouvelle méthode d'accés vasculaire pour hémodialyse. Néphrologie 1986; 7: 57-61
    • (1986) Néphrologie , vol.7 , pp. 57-61
    • Canaud, B.1    Saunier, F.2    Beraud, J.J.3    Joyeux, H.4    Mion, C.5
  • 3
    • 0028198771 scopus 로고
    • Double catheterization of the internal jugular vein for hemodialysis: Indications, techniques and clinical results
    • Tesio F, De-Baz H, Panarello G, Quaia P, Raimondi A, Schinella D. Double catheterization of the internal jugular vein for hemodialysis: indications, techniques and clinical results. Artif Organs 1994; 18(4):301-304
    • (1994) Artif Organs , vol.18 , Issue.4 , pp. 301-304
    • Tesio, F.1    De-Baz, H.2    Panarello, G.3    Quaia, P.4    Raimondi, A.5    Schinella, D.6
  • 4
  • 5
    • 0024539684 scopus 로고
    • Successful use of doublelumen, silicone rubber catheters for permanent hemodialysis access
    • Shusterman NH, Kloss K, Mullen JL. Successful use of doublelumen, silicone rubber catheters for permanent hemodialysis access. Kidney Int 1989; 35: 887-890
    • (1989) Kidney Int , vol.35 , pp. 887-890
    • Shusterman, N.H.1    Kloss, K.2    Mullen, J.L.3
  • 6
    • 0025871822 scopus 로고
    • Five years experience with Quinton Permcath for vascular access
    • Gibson SP, Mosquera D. Five years experience with Quinton Permcath for vascular access. Nephrol Dial Transplant 1991;6: 269-274
    • (1991) Nephrol Dial Transplant , vol.6 , pp. 269-274
    • Gibson, S.P.1    Mosquera, D.2
  • 8
    • 0020581602 scopus 로고
    • Experience using central venous access for long-term hemodialysis
    • McGonigle DJ, Shrock LG, Hickman RO. Experience using central venous access for long-term hemodialysis. Am J Surg 1983; 145: 571-573
    • (1983) Am J Surg , vol.145 , pp. 571-573
    • McGonigle, D.J.1    Shrock, L.G.2    Hickman, R.O.3
  • 9
    • 0024242554 scopus 로고
    • Use of silicone catheter with a Dacron cuff for dialysis short-term vascular access
    • Moss AH, McLaughlin MM, Lempert KD, Holley JL. Use of silicone catheter with a Dacron cuff for dialysis short-term vascular access. Am J Kidney Dis 1988; 12(6): 492-498
    • (1988) Am J Kidney Dis , vol.12 , Issue.6 , pp. 492-498
    • Moss, A.H.1    McLaughlin, M.M.2    Lempert, K.D.3    Holley, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.