메뉴 건너뛰기




Volumn 52, Issue 7, 1997, Pages 668-672

The Oxyvent. An anaesthetic machine designed to be used in developing countries and difficult situations

Author keywords

Equipment; anaesthesia machine, drawover system, compressor, oxygen concentrator, ventilator

Indexed keywords

OXYGEN;

EID: 0030792707     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2044.1997.167-az0301.x     Document Type: Article
Times cited : (22)

References (17)
  • 1
    • 0020529045 scopus 로고
    • Inhalational anaesthesia in developing countries 1. The problem and the proposed solution
    • Ezi-Ashi TI, Papworth DP, Nunn JF. Inhalational anaesthesia in developing countries 1. The problem and the proposed solution. Anaesthesia 1983; 38: 729-35.
    • (1983) Anaesthesia , vol.38 , pp. 729-735
    • Ezi-Ashi, T.I.1    Papworth, D.P.2    Nunn, J.F.3
  • 2
    • 0020606492 scopus 로고
    • Inhalational anaesthesia in developing countries 2. Review of existing apparatus
    • Ezi-Ashi TI, Papworth DP, Nunn JF. Inhalational anaesthesia in developing countries 2. Review of existing apparatus. Anaesthesia 1983; 38: 736-47.
    • (1983) Anaesthesia , vol.38 , pp. 736-747
    • Ezi-Ashi, T.I.1    Papworth, D.P.2    Nunn, J.F.3
  • 3
    • 0013963082 scopus 로고
    • Anaesthesia in difficult situations (3). General anaesthesia technique
    • Boulton TB. Anaesthesia in difficult situations (3). General anaesthesia technique. Anaesthesia 1966; 21: 513-45.
    • (1966) Anaesthesia , vol.21 , pp. 513-545
    • Boulton, T.B.1
  • 5
    • 0142055663 scopus 로고
    • A new ventilator for developing countries and difficult situations
    • Manley R. A new ventilator for developing countries and difficult situations. World Anaesthesia Newsletter 1991; 5: 10-11.
    • (1991) World Anaesthesia Newsletter , vol.5 , pp. 10-11
    • Manley, R.1
  • 6
    • 1842308235 scopus 로고
    • Preliminary clinical experience with the Manley Multivent in Mulago Hospital, Uganda
    • Tindimwebwa VB, Mijumbi C. Preliminary clinical experience with the Manley Multivent in Mulago Hospital, Uganda. World Anaesthesia Newsletter 1992; 7: 5.
    • (1992) World Anaesthesia Newsletter , vol.7 , pp. 5
    • Tindimwebwa, V.B.1    Mijumbi, C.2
  • 9
    • 0024395312 scopus 로고
    • The Malawi anaesthetic machine (experience with a new type of anaesthetic apparatus for developing countries)
    • Fenton PM. The Malawi anaesthetic machine (experience with a new type of anaesthetic apparatus for developing countries). Anaesthesia 1989; 44: 498-503.
    • (1989) Anaesthesia , vol.44 , pp. 498-503
    • Fenton, P.M.1
  • 10
  • 11
    • 0019792425 scopus 로고
    • The Triservice anaesthetic apparatus
    • Houghton IT. The Triservice anaesthetic apparatus. Anaesthesia 1981; 36: 1094-108.
    • (1981) Anaesthesia , vol.36 , pp. 1094-1108
    • Houghton, I.T.1
  • 12
    • 0023099732 scopus 로고
    • Drawover anaesthetic systems
    • Mackie AM. Drawover anaesthetic systems. Anaesthesia 1987; 42: 299-304.
    • (1987) Anaesthesia , vol.42 , pp. 299-304
    • Mackie, A.M.1
  • 15
    • 1842383291 scopus 로고
    • Further experience with the Penlon Manley Multivent ventilator. Its use with the modified DeVilbiss Oxygen Concentrator
    • Eltringham R. Further experience with the Penlon Manley Multivent ventilator. Its use with the modified DeVilbiss Oxygen Concentrator. World Anaesthesia Newsletter 1994; 11: 10-11.
    • (1994) World Anaesthesia Newsletter , vol.11 , pp. 10-11
    • Eltringham, R.1
  • 16
    • 0023098627 scopus 로고
    • Twelve year clinical study of patients with hypoxic cor pulmonale given long term domiciliary oxygen therapy
    • Cooper CB, Waterhouse J, Howard P. Twelve year clinical study of patients with hypoxic cor pulmonale given long term domiciliary oxygen therapy. Thorax 1987; 42: 105-10.
    • (1987) Thorax , vol.42 , pp. 105-110
    • Cooper, C.B.1    Waterhouse, J.2    Howard, P.3
  • 17
    • 0025911693 scopus 로고
    • Use of an oxygen concentrator linked to a drawover vaporizer (anesthesia delivery system for underdeveloped nations)
    • Jarvis DA, Brock-Utne JG. Use of an oxygen concentrator linked to a drawover vaporizer (anesthesia delivery system for underdeveloped nations). Anesthesia and Analgesia 1991; 72: 805-810.
    • (1991) Anesthesia and Analgesia , vol.72 , pp. 805-810
    • Jarvis, D.A.1    Brock-Utne, J.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.