메뉴 건너뛰기




Volumn 106, Issue 8, 1997, Pages 653-656

Electrical impedance of the cochlear implant lubricants hyaluronic acid, oxycellulose, and glycerin

Author keywords

Cochlear implant; Electrical resistivity; Evoked responses; Impedance; Lubricative substances

Indexed keywords

GLYCEROL; HYALURONIC ACID; HYDROXYPROPYLMETHYLCELLULOSE; LUBRICATING AGENT;

EID: 0030792596     PISSN: 00034894     EISSN: None     Source Type: Journal    
DOI: 10.1177/000348949710600807     Document Type: Article
Times cited : (6)

References (9)
  • 1
    • 0027248538 scopus 로고
    • Intrakochleare Plazierung der Cochlear-Implant-Elektroden in soft surgery technique
    • Lehnhardt E. Intrakochleare Plazierung der Cochlear-Implant-Elektroden in soft surgery technique. HNO 1993;41:356-9.
    • (1993) HNO , vol.41 , pp. 356-359
    • Lehnhardt, E.1
  • 2
    • 0029081792 scopus 로고
    • Effects of glycerin, hyaluronic acid, and hydroxypropyl methylcellulose on the spiral ganglion of the guinea pig cochlea
    • Roland JT Jr, MagardinoTM, Go JT, Hillman DE. Effects of glycerin, hyaluronic acid, and hydroxypropyl methylcellulose on the spiral ganglion of the guinea pig cochlea. Ann Otol Rhinol Laryngol Suppl 1995;104(suppl 166):64-8.
    • (1995) Ann Otol Rhinol Laryngol Suppl , vol.104 , Issue.SUPPL. 166 , pp. 64-68
    • Roland Jr., J.T.1    Magardino, T.M.2    Go, J.T.3    Hillman, D.E.4
  • 3
    • 0021668685 scopus 로고
    • Implanted material tolerance studies for a multiple-channel cochlear implant prosthesis
    • Shepherd RK, Webb RL, Clark CM, et al. Implanted material tolerance studies for a multiple-channel cochlear implant prosthesis. Acta Otolaryngol Suppl (Stockh) 1984(suppl 411):71-81.
    • (1984) Acta Otolaryngol Suppl (Stockh) , Issue.SUPPL. 411 , pp. 71-81
    • Shepherd, R.K.1    Webb, R.L.2    Clark, C.M.3
  • 5
    • 0026800626 scopus 로고
    • The effects of limiting the number of Nucleus 22 cochlear implant electrodes programmed on speech perception
    • Geier LL, Norton SJ. The effects of limiting the number of Nucleus 22 cochlear implant electrodes programmed on speech perception. Ear Hear 1992;13:340-8.
    • (1992) Ear Hear , vol.13 , pp. 340-348
    • Geier, L.L.1    Norton, S.J.2
  • 6
    • 0029161090 scopus 로고
    • Initial investigation of the efficacy and biosafety of sodium hyaluronate (Healon) as an aid to electrode array insertion
    • Donnelly MJ, Cohen LT, Clark GM. Initial investigation of the efficacy and biosafety of sodium hyaluronate (Healon) as an aid to electrode array insertion. Ann Otol Rhinol Laryngol Suppl 1995;104(suppl 166):45-8.
    • (1995) Ann Otol Rhinol Laryngol Suppl , vol.104 , Issue.SUPPL. 166 , pp. 45-48
    • Donnelly, M.J.1    Cohen, L.T.2    Clark, G.M.3
  • 7
    • 36149068108 scopus 로고
    • Specific electrical resistance of body tissues
    • Burger CH, Van Dongen R. Specific electrical resistance of body tissues. Phys Med Biol 1964;5:431-47.
    • (1964) Phys Med Biol , vol.5 , pp. 431-447
    • Burger, C.H.1    Van Dongen, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.