메뉴 건너뛰기




Volumn 38, Issue 7, 1997, Pages 1059-1066

Three-dimensional dosimetry for intralesional radionuclide therapy using mathematical modeling and multimodality imaging

Author keywords

Dosimetry; Glioma; Image registration; Intralesional therapy; Radioimmunotherapy

Indexed keywords

ARTICLE; DOSIMETRY; GLIOMA; PRIORITY JOURNAL; RADIATION DOSE; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING;

EID: 0030789208     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (12)
  • 1
    • 0024386838 scopus 로고
    • 131-labeled anti-tenascin monoclonal antibody 81C6 in patients with glioma and other intracranial malignancies
    • 131-labeled anti-tenascin monoclonal antibody 81C6 in patients with glioma and other intracranial malignancies. Cancer Res 1989;49:2807-2813.
    • (1989) Cancer Res , vol.49 , pp. 2807-2813
    • Zalutsky, M.1    Moseley, P.2    Coakam, H.B.3    Coleman, R.E.4    Bigner, D.5
  • 2
    • 0038720544 scopus 로고
    • A revised scheme for calculating the absorbed dose from biologically distributed radionuclides
    • New York, NY: Society of Nuclear Medicine
    • Loevinger R, Berman M. A revised scheme for calculating the absorbed dose from biologically distributed radionuclides. MIRD pamphlet No. 1, revised. New York, NY: Society of Nuclear Medicine; 1976.
    • (1976) MIRD Pamphlet No. 1, Revised , vol.1
    • Loevinger, R.1    Berman, M.2
  • 3
    • 2642625158 scopus 로고
    • 131I-monoclonal antibody (MAb) therapy in patients with recurrent high-grade gliomas: Radioactive isotopes in clinical medicine research
    • Basel, Switzerland: Birkhauser Verlag
    • 131I-monoclonal antibody (MAb) therapy in patients with recurrent high-grade gliomas: radioactive isotopes in clinical medicine research. In: Radioactive isotopes in clinical medical research. Advances in pharmacological sciences, Basel, Switzerland: Birkhauser Verlag; 1995:29-34.
    • (1995) Radioactive Isotopes in Clinical Medical Research. Advances in Pharmacological Sciences , pp. 29-34
    • Chittenden, S.1    Thomas, R.2    Hall, A.3
  • 4
    • 0027223126 scopus 로고
    • A model for calculating tumor-control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic-cell density
    • Webb S, Nahum AE. A model for calculating tumor-control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic-cell density. Phys Med Biol 1993;38:653-666.
    • (1993) Phys Med Biol , vol.38 , pp. 653-666
    • Webb, S.1    Nahum, A.E.2
  • 5
    • 0025144572 scopus 로고
    • Treatment planning for internal radionuclide therapy: Three-dimensional dosimetry for nonuniformly distributed radionuclides
    • Sgouros G, Barest G, Thekkumthala J, et al. Treatment planning for internal radionuclide therapy: three-dimensional dosimetry for nonuniformly distributed radionuclides. J Nucl Med 1990;31:1884-1891.
    • (1990) J Nucl Med , vol.31 , pp. 1884-1891
    • Sgouros, G.1    Barest, G.2    Thekkumthala, J.3
  • 6
    • 0027225966 scopus 로고
    • Three-dimensional dosimetry for radioimmunotherapy treatment planning
    • Sgouros G, Chui S, Pentlow KS, et al. Three-dimensional dosimetry for radioimmunotherapy treatment planning. J Nucl Med 1993;34:1595-1601.
    • (1993) J Nucl Med , vol.34 , pp. 1595-1601
    • Sgouros, G.1    Chui, S.2    Pentlow, K.S.3
  • 7
    • 33749815139 scopus 로고
    • Accurate three-dimensional dose calculation using a quantitative SPECT image for radioimmunotherapy
    • Ogawa K, Kanbe N, Uchida I, Yamada Y, Itoh A, Akiyama Y. Accurate three-dimensional dose calculation using a quantitative SPECT image for radioimmunotherapy [Abstract], J Nucl Med 1994;35(suppl):160P.
    • (1994) J Nucl Med , vol.35 , Issue.SUPPL.
    • Ogawa, K.1    Kanbe, N.2    Uchida, I.3    Yamada, Y.4    Itoh, A.5    Akiyama, Y.6
  • 8
    • 0028946465 scopus 로고
    • Validation of a dose-point kernel convolution technique for internal dosimetry
    • Giap HB, Macey DJ, Bayouth JE, Boyer AE. Validation of a dose-point kernel convolution technique for internal dosimetry. Phys Med Biol 1990;40:365-381.
    • (1990) Phys Med Biol , vol.40 , pp. 365-381
    • Giap, H.B.1    Macey, D.J.2    Bayouth, J.E.3    Boyer, A.E.4
  • 10
    • 0025797431 scopus 로고
    • Dosimetry of iodine-131 metaiodobenzylguanidine for treatment of resistant neuroblastoma: Results of a UK study
    • Fielding SL, Flower MA, Ackery D, Kemshead JT, Lashford LS, Lewis I. Dosimetry of iodine-131 metaiodobenzylguanidine for treatment of resistant neuroblastoma: results of a UK study. Eur J Nucl Med 1991;18:308-316.
    • (1991) Eur J Nucl Med , vol.18 , pp. 308-316
    • Fielding, S.L.1    Flower, M.A.2    Ackery, D.3    Kemshead, J.T.4    Lashford, L.S.5    Lewis, I.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.