메뉴 건너뛰기




Volumn 80, Issue 11, 1997, Pages 1489-1490

Tolerability of internal low-energy shock strengths currently needed for endocardial atrial cardioversion

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CARDIOVERSION; CLINICAL ARTICLE; ELECTRIC SHOCK; ENERGY; FEMALE; HEART ATRIUM FIBRILLATION; HUMAN; MALE; PATIENT SATISFACTION; PRIORITY JOURNAL;

EID: 0030785475     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(97)00733-9     Document Type: Article
Times cited : (31)

References (6)
  • 2
    • 0028956957 scopus 로고
    • Efficacy and tolerability of transvenous low energy cardioversion in paroxysmal atrial fibrillation in humans
    • Murgatroyd FD, Slade AK, Sopher SM, Rowland E, Ward DE, Camm AJ. Efficacy and tolerability of transvenous low energy cardioversion in paroxysmal atrial fibrillation in humans. J Am Coll Cardiol. 25:1995;1347-1353.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1347-1353
    • Murgatroyd, F.D.1    Slade, A.K.2    Sopher, S.M.3    Rowland, E.4    Ward, D.E.5    Camm, A.J.6
  • 3
    • 0028785430 scopus 로고
    • Clinical efficacy and safety of atrial defibrillation using biphasic shocks and current nonthoracotomy endocardial lead configurations
    • Saksena S, Prakash A, Mangeon L, Varanasi S, Kolettis T, Methew P, De Groot P, Mehra R, Krol R. Clinical efficacy and safety of atrial defibrillation using biphasic shocks and current nonthoracotomy endocardial lead configurations. Am J Cardiol. 76:1995;913-921.
    • (1995) Am J Cardiol , vol.76 , pp. 913-921
    • Saksena, S.1    Prakash, A.2    Mangeon, L.3    Varanasi, S.4    Kolettis, T.5    Methew, P.6    De Groot, P.7    Mehra, R.8    Krol, R.9
  • 5
    • 0030246871 scopus 로고    scopus 로고
    • Testing different biphasic waveforms and capacitances: Effect on atrial defibrillation threshold and pain perception
    • Tomassoni G, Newby KH, Kearney MM, Brandon MJ, Barold H, Natale A. Testing different biphasic waveforms and capacitances effect on atrial defibrillation threshold and pain perception . J Am Coll Cardiol. 28:1996;695-699.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 695-699
    • Tomassoni, G.1    Newby, K.H.2    Kearney, M.M.3    Brandon, M.J.4    Barold, H.5    Natale, A.6
  • 6
    • 0030589016 scopus 로고    scopus 로고
    • Feasibility of atrial fibrillation detection and use of a preceding synchronization interval as a criterion for shock delivery in humans with atrial fibrillation
    • Sra JS, Maglio C, Dhala A, Blanck Z, Biehl M, Deshpande S, Keelan ET, Jazayeri MR, Akhtar M. Feasibility of atrial fibrillation detection and use of a preceding synchronization interval as a criterion for shock delivery in humans with atrial fibrillation. J Am Coll Cardiol. 228:1996;1532-1538.
    • (1996) J Am Coll Cardiol , vol.228 , pp. 1532-1538
    • Sra, J.S.1    Maglio, C.2    Dhala, A.3    Blanck, Z.4    Biehl, M.5    Deshpande, S.6    Keelan, E.T.7    Jazayeri, M.R.8    Akhtar, M.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.