메뉴 건너뛰기




Volumn 96, Issue 7, 1997, Pages 2124-2127

Intravascular ultrasound-guided percutaneous fenestration of the intimal flap in the dissected aorta

Author keywords

Dissection, aortic; Fenestration; Ultrasonics

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ABDOMINAL PAIN; ADULT; AORTA DISEASE; AORTA DISSECTING ANEURYSM; AORTA DISSECTION; ARTICLE; CLAUDICATION; CLINICAL ARTICLE; HUMAN; INTRAVASCULAR ULTRASOUND; MALE; PERIPHERAL VASCULAR DISEASE; PRIORITY JOURNAL; SYMPTOMATOLOGY; TREATMENT OUTCOME;

EID: 0030770393     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.96.7.2124     Document Type: Article
Times cited : (96)

References (21)
  • 5
    • 1542515503 scopus 로고
    • Management of thoracoabdominal malperfusion in aortic dissection
    • Laas J, Heinemann M, Schaefers HJ, Daniel W, Borst HG. Management of thoracoabdominal malperfusion in aortic dissection. Circulation. 1991;84(suppl III):III-20-III-24.
    • (1991) Circulation , vol.84 , Issue.3 SUPPL.
    • Laas, J.1    Heinemann, M.2    Schaefers, H.J.3    Daniel, W.4    Borst, H.G.5
  • 6
    • 0020308869 scopus 로고
    • Dissection and dissecting aneurysms of the aorta: Twenty-year follow-up of five hundred twenty-seven patients treated surgically
    • DeBakey ME, McCollum CH, Crawford ES, Morris GC, Howell J, Noon GP, Lawrie G. Dissection and dissecting aneurysms of the aorta: twenty-year follow-up of five hundred twenty-seven patients treated surgically. Surgery. 1982;92:1118-1134.
    • (1982) Surgery , vol.92 , pp. 1118-1134
    • DeBakey, M.E.1    McCollum, C.H.2    Crawford, E.S.3    Morris, G.C.4    Howell, J.5    Noon, G.P.6    Lawrie, G.7
  • 7
    • 0025303188 scopus 로고
    • Fenestration revisited: A safe and effective procedure for descending aortic dissection
    • Elefteriades JA, Hammond GL, Gusberg RJ, Kopf GS, Baldwin JC. Fenestration revisited: a safe and effective procedure for descending aortic dissection. Arch Surg. 1990;125:786-790.
    • (1990) Arch Surg. , vol.125 , pp. 786-790
    • Elefteriades, J.A.1    Hammond, G.L.2    Gusberg, R.J.3    Kopf, G.S.4    Baldwin, J.C.5
  • 8
    • 0025176967 scopus 로고
    • Relief of mesenteric ischemia in type III aortic dissection with percutaneous fenestration of the aortic septum
    • Williams DM, Brothers TE, Messina LM. Relief of mesenteric ischemia in type III aortic dissection with percutaneous fenestration of the aortic septum. Radiology. 1990;174:450-452.
    • (1990) Radiology , vol.174 , pp. 450-452
    • Williams, D.M.1    Brothers, T.E.2    Messina, L.M.3
  • 9
    • 0027349525 scopus 로고
    • Creation of reentry tears in aortic dissection by means of percutaneous balloon fenestration: Gross anatomic and histologic considerations
    • Williams DM, Andrews JC, Marx V, Abrams GD. Creation of reentry tears in aortic dissection by means of percutaneous balloon fenestration: gross anatomic and histologic considerations. J Vasc Interv Radiol. 1993;4:75-83.
    • (1993) J Vasc Interv Radiol. , vol.4 , pp. 75-83
    • Williams, D.M.1    Andrews, J.C.2    Marx, V.3    Abrams, G.D.4
  • 10
    • 0027714809 scopus 로고
    • The use of endovascular techniques for the treatment of complications of aortic dissection
    • Walker PJ, Dake MD, Mitchell RS, Miller DC. The use of endovascular techniques for the treatment of complications of aortic dissection. J Vasc Surg. 1993;18:1042-1051.
    • (1993) J Vasc Surg. , vol.18 , pp. 1042-1051
    • Walker, P.J.1    Dake, M.D.2    Mitchell, R.S.3    Miller, D.C.4
  • 11
    • 0028964004 scopus 로고
    • Percutaneous treatment of a traumatic aortic dissection by balloon fenestration and stent placement
    • Peterson AH, Williams DM, Rodriguez JL, Francis IR. Percutaneous treatment of a traumatic aortic dissection by balloon fenestration and stent placement. AJR Am J Roentgenol. 1995;164: 1274-1276.
    • (1995) AJR am J Roentgenol. , vol.164 , pp. 1274-1276
    • Peterson, A.H.1    Williams, D.M.2    Rodriguez, J.L.3    Francis, I.R.4
  • 12
    • 0030049470 scopus 로고    scopus 로고
    • Aortic dissection: Percutaneous management of ischaemic complications with endovascular stents and balloon fenestration
    • Slonim SM, Nyman U, Semba CP, Miller DC, Mitchell SR, Dake MD. Aortic dissection: percutaneous management of ischaemic complications with endovascular stents and balloon fenestration. J Vasc Surg. 1996;23:241-253.
    • (1996) J Vasc Surg. , vol.23 , pp. 241-253
    • Slonim, S.M.1    Nyman, U.2    Semba, C.P.3    Miller, D.C.4    Mitchell, S.R.5    Dake, M.D.6
  • 14
    • 0027352160 scopus 로고
    • The continuing dilemma concerning medical versus surgical management of acute type B dissections
    • Miller DC. The continuing dilemma concerning medical versus surgical management of acute type B dissections. Semin Thorac Cardiovasc Surg. 1993;5:33-46.
    • (1993) Semin Thorac Cardiovasc Surg. , vol.5 , pp. 33-46
    • Miller, D.C.1
  • 16
    • 0026637259 scopus 로고
    • Percutaneous fenestration of type I aortic dissection for relief of lower extremity ischaemia
    • Faykus MH, Hiette P, Koopot R. Percutaneous fenestration of type I aortic dissection for relief of lower extremity ischaemia. Cardiovasc Intervent Radiol. 1992;15:183-185.
    • (1992) Cardiovasc Intervent Radiol. , vol.15 , pp. 183-185
    • Faykus, M.H.1    Hiette, P.2    Koopot, R.3
  • 17
    • 0026642891 scopus 로고
    • Percutaneous fenestration of dissecting intima with a transseptal needle: A new therapeutic technique for visceral ischaemia complicating acute aortic dissection
    • Saito S, Arai H, Kim K, Aoki N, Tsurugida M. Percutaneous fenestration of dissecting intima with a transseptal needle: a new therapeutic technique for visceral ischaemia complicating acute aortic dissection. Cathet Cardiovasc Diagn. 1992;26:130-135.
    • (1992) Cathet Cardiovasc Diagn. , vol.26 , pp. 130-135
    • Saito, S.1    Arai, H.2    Kim, K.3    Aoki, N.4    Tsurugida, M.5
  • 18
    • 0027283527 scopus 로고
    • Relief of acute lower limb ischaemia with percutaneous fenestration of intimal flap in a patient with type III aortic dissection: A case report
    • Kato N, Sakuma H, Takeda K, Hirano T, Nakagawa T. Relief of acute lower limb ischaemia with percutaneous fenestration of intimal flap in a patient with type III aortic dissection: a case report. Angiology. 1993;44:755-759.
    • (1993) Angiology , vol.44 , pp. 755-759
    • Kato, N.1    Sakuma, H.2    Takeda, K.3    Hirano, T.4    Nakagawa, T.5
  • 20
    • 0028783654 scopus 로고
    • Transfemorale Fensterung und Stentimplantation bei aorto-iliakaler Dissektion
    • Farber A, Gmelin E, Heinemann M. Transfemorale Fensterung und Stentimplantation bei aorto-iliakaler Dissektion. Vasa. 1995; 24:389-391.
    • (1995) Vasa. , vol.24 , pp. 389-391
    • Farber, A.1    Gmelin, E.2    Heinemann, M.3
  • 21
    • 0030453052 scopus 로고    scopus 로고
    • Intravasaler Ultraschall zur Steuerung der perkutanen Fenestration einer Aortendissektionsmembran
    • Gorge G, Erbel R. Intravasaler Ultraschall zur Steuerung der perkutanen Fenestration einer Aortendissektionsmembran. Dtsch Med Wochenschr. 1996;121:1598-1602.
    • (1996) Dtsch Med Wochenschr. , vol.121 , pp. 1598-1602
    • Gorge, G.1    Erbel, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.