1
-
-
0028249596
-
Reusable instruments are more cost-effective than disposable instruments for laparoscopic cholecystectomy
-
KW Apelgren ML Blank CA Slomski NS Hadjis Reusable instruments are more cost-effective than disposable instruments for laparoscopic cholecystectomy Surg Endosc 8 1994 32 34
-
(1994)
Surg Endosc
, vol.8
, pp. 32-34
-
-
Apelgren, KW1
Blank, ML2
Slomski, CA3
Hadjis, NS4
-
2
-
-
85114530531
-
Standard Test Method for Apparent Bending Modulus of Plastics by Means of a Cantilever Beam, D747-90
-
American Society for Testing and Materials Standard Test Method for Apparent Bending Modulus of Plastics by Means of a Cantilever Beam, D747-90 1990 American Society for Testing and Materials Philadelphia
-
(1990)
-
-
American Society for Testing and Materials1
-
3
-
-
85114539674
-
Standard Method of Test for Tensile Properties of Plastics, D638-72
-
American Society for Testing and Materials Standard Method of Test for Tensile Properties of Plastics, D638-72 1972 American Society for Testing and Materials Philadelphia
-
(1972)
-
-
American Society for Testing and Materials1
-
4
-
-
85114547326
-
Scoring biological safety tests: What's a pass or a fail?
-
RF Wallin Scoring biological safety tests: What's a pass or a fail? Med Plast Biomater 1 1994 38 41 55
-
(1994)
Med Plast Biomater
, vol.1
, pp. 38-41
-
-
Wallin, RF1
-
5
-
-
0027482894
-
Recycling of cardiopulmonary bypass cannulae; a risk-benefit analysis
-
RJ Novick Recycling of cardiopulmonary bypass cannulae; a risk-benefit analysis Can J Surg 36 1993 431 434
-
(1993)
Can J Surg
, vol.36
, pp. 431-434
-
-
Novick, RJ1
-
6
-
-
0020631756
-
Fever, chills, and hypotension following cardiac catheterization with single- and multiple-use disposable catheters
-
JA Jacobson CE Schwartz HW Marshall M Conti JP Burke Fever, chills, and hypotension following cardiac catheterization with single- and multiple-use disposable catheters Cathet Cardiovasc Diagn 9 1983 39 46
-
(1983)
Cathet Cardiovasc Diagn
, vol.9
, pp. 39-46
-
-
Jacobson, JA1
Schwartz, CE2
Marshall, HW3
Conti, M4
Burke, JP5
-
7
-
-
0023685703
-
Infection risk of cardiac catheterization and arterial angiography with single- and multiple-use disposable catheter
-
U Frank L Herz FD Daschner Infection risk of cardiac catheterization and arterial angiography with single- and multiple-use disposable catheter Clin Cardiol 11 1988 785 787
-
(1988)
Clin Cardiol
, vol.11
, pp. 785-787
-
-
Frank, U1
Herz, L2
Daschner, FD3
-
8
-
-
0028126732
-
Reuse of balloon catheters for coronary angioplasty: A potential cost-saving strategy?
-
S Plante BH Strauss G Goulet R Watson RJ Chisholm Reuse of balloon catheters for coronary angioplasty: A potential cost-saving strategy? J Am Coll Cardiol 24 1994 1475 1481
-
(1994)
J Am Coll Cardiol
, vol.24
, pp. 1475-1481
-
-
Plante, S1
Strauss, BH2
Goulet, G3
Watson, R4
Chisholm, RJ5
-
9
-
-
0001426203
-
The reuse of single-use cardiac catheters: safety, economical, ethical and legal issues
-
Conseil d'évaluation des technologies de la santé du Québec The reuse of single-use cardiac catheters: safety, economical, ethical and legal issues Can J Cardiol 10 1994 413 421
-
(1994)
Can J Cardiol
, vol.10
, pp. 413-421
-
-
Conseil d'évaluation des technologies de la santé du Québec1
-
11
-
-
85114524185
-
Standard Test Method for Determination of Effectiveness of Sterilization Processes for Reusable Medical Devices, E1766-95
-
American Society for Testing and Materials Standard Test Method for Determination of Effectiveness of Sterilization Processes for Reusable Medical Devices, E1766-95 1995 American Society for Testing and Materials Philadelphia
-
(1995)
-
-
American Society for Testing and Materials1
-
12
-
-
85114540925
-
-
DM Bucci D Richardson D Bloom PS Malchesky Effect of blood soiling on sterilization efficacy. Presented at the Thirty-first Annual Meeting of Association for Advancement of Medical Instrumentation, 1996, Philadelphia June 2, 1996
-
(1996)
-
-
Bucci, DM1
Richardson, D2
Bloom, D3