Volumn 413, Issue , 1997, Pages 129-137

Correlation between absolute deoxyhaemoglobin [dHb] measured by near infrared spectroscopy (NIRS) and absolute R2' as determined by magnetic resonance imaging (MRI)

Author keywords

[No Author keywords available]

Indexed keywords

DEOXYHEMOGLOBIN;

EID: 0030759432     PISSN: 00652598     EISSN: None     Source Type: Book Series    
DOI: 10.1007/978-1-4899-0056-2_14     Document Type: Article
Times cited : (18)

References (15)
  • 2
    • 0027263961 scopus 로고
    • Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging
    • Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G. Merkle, H., Ellermann, J. M., and Ugurbil, K., 1993, Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging, Biophys. J., 64:803-812.
    • (1993) Biophys. J. , vol.64 , pp. 803-812
    • Ogawa, S.1    Menon, R.S.2    Tank, D.W.3    Kim, S.G.4    Merkle, H.5    Ellermann, J.M.6    Ugurbil, K.7
  • 3
    • 0028387388 scopus 로고
    • Comparison of EPI Gradient-Echo Contrast Changes in Cat Brain Caused by Respiratory Challenges with Direct Simultaneous Evaluation of Cerebral Oxygenation via a Cranial Window
    • Jezzard, P., Heineman, F., Taylor, J., DesPres, D., Wen, H., Balaban, R. S., and Turner, R., 1994, Comparison of EPI Gradient-Echo Contrast Changes in Cat Brain Caused By Respiratory Challenges with Direct Simultaneous Evaluation of Cerebral Oxygenation via a Cranial Window, NMR Biomed., 7:35-44
    • (1994) NMR Biomed. , vol.7 , pp. 35-44
    • Jezzard, P.1    Heineman, F.2    Taylor, J.3    DesPres, D.4    Wen, H.5    Balaban, R.S.6    Turner, R.7
  • 4
    • 0023019602 scopus 로고
    • Qualification of cerebral oxygenation and hemodynamics in sick newborn infants by near infra red spectrophotometry
    • Wyatt, J. S., Cope, M., Delpy, D. T., Edwards, A. D., Wray, S. C., and Reynolds, E. O. R., 1986, Qualification of cerebral oxygenation and hemodynamics in sick newborn infants by near infra red spectrophotometry, Lancet, II: 1063-1066
    • (1986) Lancet , vol.2 , pp. 1063-1066
    • Wyatt, J.S.1    Cope, M.2    Delpy, D.T.3    Edwards, A.D.4    Wray, S.C.5    Reynolds, E.O.R.6
  • 5
    • 0028081969 scopus 로고
    • Use of water absorption spectrum to quantify tissue chromophore concentration changes in near infrared spectroscopy
    • Matcher, S. J., Cope, M., Delpy, D. T., 1994, Use of water absorption spectrum to quantify tissue chromophore concentration changes in near infrared spectroscopy, Phys. Med. Biol., 39:177-196
    • (1994) Phys. Med. Biol. , vol.39 , pp. 177-196
    • Matcher, S.J.1    Cope, M.2    Delpy, D.T.3
  • 6
    • 0028136374 scopus 로고
    • Absolute quantification of deoxyhaemoglobin concentration in tissue near infrared spectroscopy
    • Matcher, S. J., and Cooper, C. E., 1994, Absolute quantification of deoxyhaemoglobin concentration in tissue near infrared spectroscopy, Phys. Med. Biol., 39:1295-1312.
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1295-1312
    • Matcher, S.J.1    Cooper, C.E.2
  • 7
    • 8544241466 scopus 로고
    • The non-invasive measurement of absolute cerebral deoxyhaemoglobin concentration and mean optical pathlength in the neonatal brain by second derivative near infrared spectroscopy
    • In press
    • Cooper, C. E., Elwell, C. E., Meek, H., Matcher, S. J., Wyatt, J. S., Cope, M., and Delpy, D. T. 1995, The non-invasive measurement of absolute cerebral deoxyhaemoglobin concentration and mean optical pathlength in the neonatal brain by second derivative near infrared spectroscopy, Pediatr. Res., In press.
    • (1995) Pediatr. Res.
    • Cooper, C.E.1    Elwell, C.E.2    Meek, H.3    Matcher, S.J.4    Wyatt, J.S.5    Cope, M.6    Delpy, D.T.7
  • 9
    • 0027973923 scopus 로고
    • Theory of NMR Signal Behavior in Magnetically Inhomogeneous Tissues: The Static Dephasing Regime
    • Yablonskiy, D. A., and Haacke, E. M., 1994, Theory of NMR Signal Behavior in Magnetically Inhomogeneous Tissues: The Static Dephasing Regime, Magn. Reson. Med., 32:749-763.
    • (1994) Magn. Reson. Med. , vol.32 , pp. 749-763
    • Yablonskiy, D.A.1    Haacke, E.M.2
  • 11
    • 0024393323 scopus 로고
    • A CCD spectrometer to quantitate the concentration of chromophores in living tissue utilising the water absorption peak of water at 975 mm
    • Cope, M., Delpy, D. T., Wyatt, J. S., Wray, S. C., Reynolds, E. O. R., 1989, A CCD spectrometer to quantitate the concentration of chromophores in living tissue utilising the water absorption peak of water at 975 mm, Adv. Exp. Med. Biol., 247:33-31.
    • (1989) Adv. Exp. Med. Biol. , vol.247 , pp. 33-131
    • Cope, M.1    Delpy, D.T.2    Wyatt, J.S.3    Wray, S.C.4    Reynolds, E.O.R.5
  • 13
    • 0026767986 scopus 로고
    • Health and physiological effects of human exposure to whole body four tesla magnetic fields during MRI
    • Schenk, J. F., 1992, Health and physiological effects of human exposure to whole body four tesla magnetic fields during MRI., Ann. N. Y. Acad. Sci., 649:285-301.
    • (1992) Ann. N. Y. Acad. Sci. , vol.649 , pp. 285-301
    • Schenk, J.F.1
  • 15
    • 0029060006 scopus 로고
    • Performance Comparison of Several Published Tissue Near-Infrared Spectroscopy Algorithms
    • Matcher, S. J., Elwell, C. E., Cooper, C. E., Cope, M., and Delpy, D. T., 1995, Performance Comparison of Several Published Tissue Near-Infrared Spectroscopy Algorithms, Analyt. Biochem., 277,54-68.
    • (1995) Analyt. Biochem. , vol.277 , pp. 54-68
    • Matcher, S.J.1    Elwell, C.E.2    Cooper, C.E.3    Cope, M.4    Delpy, D.T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.