메뉴 건너뛰기




Volumn 4, Issue 3, 1997, Pages 202-210

Enhanced accuracy of defect detection by myocardial single-photon emission computed tomography with attenuation correction with gadolinium 153 line sources: Evaluation with a cardiac phantom

Author keywords

Artifacts; Attenuation correction; Single photon emission computed tomography

Indexed keywords

GADOLINIUM 153; TECHNETIUM 99M;

EID: 0030755844     PISSN: 10713581     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1071-3581(97)90080-5     Document Type: Article
Times cited : (19)

References (42)
  • 1
    • 0026091785 scopus 로고
    • Diagnostic accuracy of thallium-201 myocardial perfusion imaging
    • Beller GA. Diagnostic accuracy of thallium-201 myocardial perfusion imaging. Circulation 1991;84(suppl):11-6.
    • (1991) Circulation , vol.84 , Issue.SUPPL. , pp. 11-16
    • Beller, G.A.1
  • 2
    • 0023866534 scopus 로고
    • Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease
    • DePasquale EE, Nody AC, DePuey EG, Garcia EV, Pilcher G, Bredlau C, et al. Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease. Circulation 1988;77:316-27.
    • (1988) Circulation , vol.77 , pp. 316-327
    • DePasquale, E.E.1    Nody, A.C.2    DePuey, E.G.3    Garcia, E.V.4    Pilcher, G.5    Bredlau, C.6
  • 3
    • 0024573667 scopus 로고
    • Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts
    • DePuey EG, Garcia EV. Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts. J Nucl Med 1989;30:441-9.
    • (1989) J Nucl Med , vol.30 , pp. 441-449
    • DePuey, E.G.1    Garcia, E.V.2
  • 4
    • 0024543725 scopus 로고
    • Prone versus supine thallium myocardial SPECT: A method to decrease artifactual inferior wall defects
    • DePuey EG, Garcia EV. Prone versus supine thallium myocardial SPECT: a method to decrease artifactual inferior wall defects. J Nucl Med 1989;30:548-55.
    • (1989) J Nucl Med , vol.30 , pp. 548-555
    • DePuey, E.G.1    Garcia, E.V.2
  • 5
    • 0023833767 scopus 로고
    • Quantitative analysis of the tomographic thallium-201 myocardial bull's-eye display: Critical role of correction for patient motion
    • Eisner R, Churchwell A, Noever T, Nowak D, Cloninger K, Dunn D, et al. Quantitative analysis of the tomographic thallium-201 myocardial bull's-eye display: critical role of correction for patient motion. J Nucl Med 1988;29:91-7.
    • (1988) J Nucl Med , vol.29 , pp. 91-97
    • Eisner, R.1    Churchwell, A.2    Noever, T.3    Nowak, D.4    Cloninger, K.5    Dunn, D.6
  • 7
    • 0023117526 scopus 로고
    • Use of cross-correlation function to detect patient motion during SPECT imaging
    • Eisner RL, Noever T, Nowak D, Carlson W, Dunn D, Oates J, et al. Use of cross-correlation function to detect patient motion during SPECT imaging. J Nucl Med 1987;28:97-101.
    • (1987) J Nucl Med , vol.28 , pp. 97-101
    • Eisner, R.L.1    Noever, T.2    Nowak, D.3    Carlson, W.4    Dunn, D.5    Oates, J.6
  • 8
    • 0023950646 scopus 로고
    • Patient motion in thallium-201 myocardial SPECT imaging: An easily identified frequent source of artifactual defect
    • Friedman J, Berman DS, Van Train K, Garcia EV, Bietendorf J, Prigent F, et al. Patient motion in thallium-201 myocardial SPECT imaging: an easily identified frequent source of artifactual defect. Clin Nucl Med 1988;13:321-4.
    • (1988) Clin Nucl Med , vol.13 , pp. 321-324
    • Friedman, J.1    Berman, D.S.2    Van Train, K.3    Garcia, E.V.4    Bietendorf, J.5    Prigent, F.6
  • 9
    • 0024447286 scopus 로고
    • Upward creep of heart: Frequent source of false-positive reversible defect during 201 Tl stress redistribution SPECT
    • Friedman J, Van Train K, Maddahi J, Rozanski A, Prigent F, Bietendorf J, et al. Upward creep of heart: frequent source of false-positive reversible defect during 201 Tl stress redistribution SPECT. J Nucl Med 1989;30:1718-22.
    • (1989) J Nucl Med , vol.30 , pp. 1718-1722
    • Friedman, J.1    Van Train, K.2    Maddahi, J.3    Rozanski, A.4    Prigent, F.5    Bietendorf, J.6
  • 12
    • 85030298017 scopus 로고
    • Effect of breast attenuation on defect size measurement in myocardial SPECT imaging
    • Jang S, Jaszczak RJ, Kadrmas DJ, Greer KL, Coleman RE. Effect of breast attenuation on defect size measurement in myocardial SPECT imaging [abstract]. J Nucl Med 1995;36(suppl):40P.
    • (1995) J Nucl Med , vol.36 , Issue.SUPPL.
    • Jang, S.1    Jaszczak, R.J.2    Kadrmas, D.J.3    Greer, K.L.4    Coleman, R.E.5
  • 13
    • 0019449394 scopus 로고
    • The inconsistent pattern of thallium defects: A clue to the false-positive perfusion scintigram
    • Dunn RF, Wolff L, Wagner S, Botvinick EH. The inconsistent pattern of thallium defects: a clue to the false-positive perfusion scintigram. Am J Cardiol 1981;48:224-32.
    • (1981) Am J Cardiol , vol.48 , pp. 224-232
    • Dunn, R.F.1    Wolff, L.2    Wagner, S.3    Botvinick, E.H.4
  • 14
    • 0018095267 scopus 로고
    • Overlying breast as cause of false-positive thallium scans
    • Stolzenberg J, Kaminsky J. Overlying breast as cause of false-positive thallium scans. Clin Nucl Med 1978;3:229.
    • (1978) Clin Nucl Med , vol.3 , pp. 229
    • Stolzenberg, J.1    Kaminsky, J.2
  • 15
    • 0022376097 scopus 로고
    • Appearance of breast attenuation artifacts with thallium myocardial imaging
    • Tamaki N, Yonekura Y, Kadota K, Kambara H, Torizuka K. Appearance of breast attenuation artifacts with thallium myocardial imaging. Clin Nucl Med 1985;10:694-6.
    • (1985) Clin Nucl Med , vol.10 , pp. 694-696
    • Tamaki, N.1    Yonekura, Y.2    Kadota, K.3    Kambara, H.4    Torizuka, K.5
  • 16
    • 0017452940 scopus 로고
    • A method for attenuation correction in radionuclide computed tomography
    • Chang LT. A method for attenuation correction in radionuclide computed tomography. IEEE Trans Nucl Sci 1978;25:638-43.
    • (1978) IEEE Trans Nucl Sci , vol.25 , pp. 638-643
    • Chang, L.T.1
  • 17
    • 0023243756 scopus 로고
    • Improved SPECT using simultaneous emission and transmission tomography
    • Bailey DL, Hutton BF, Wailker PJ. Improved SPECT using simultaneous emission and transmission tomography. J Nucl Med 1987;28:844-51.
    • (1987) J Nucl Med , vol.28 , pp. 844-851
    • Bailey, D.L.1    Hutton, B.F.2    Wailker, P.J.3
  • 19
    • 0029017223 scopus 로고
    • Simultaneous transmission-emission thallium-201 cardiac SPECT: Effect of attenuation correction on myocardial tracer distribution
    • Ficaro EP, Fessier JA, Ackermann RJ, Rogers AW, Corbett JR, Schwaiger M. Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution. J Nucl Med 1995;36:921-31.
    • (1995) J Nucl Med , vol.36 , pp. 921-931
    • Ficaro, E.P.1    Fessier, J.A.2    Ackermann, R.J.3    Rogers, A.W.4    Corbett, J.R.5    Schwaiger, M.6
  • 20
    • 0026460467 scopus 로고
    • Simultaneous acquisition of emission and transmission data for improved Tl-201 cardiac SPECT imaging using a Tc-99m transmission source
    • Frey EC, Tsui BMW, Perry JR. Simultaneous acquisition of emission and transmission data for improved Tl-201 cardiac SPECT imaging using a Tc-99m transmission source. J Nucl Med 1992;33:2238-45.
    • (1992) J Nucl Med , vol.33 , pp. 2238-2245
    • Frey, E.C.1    Tsui, B.M.W.2    Perry, J.R.3
  • 21
    • 0027665228 scopus 로고
    • Fast transmission CT for determining attenuation maps using a collimated line source, rotatable air-copper-lead attenuators and fan-beam collimation
    • Jaszczak RJ, Gilland DR, Hanson MW, Jang S, Greer KL, Coleman RE. Fast transmission CT for determining attenuation maps using a collimated line source, rotatable air-copper-lead attenuators and fan-beam collimation. J Nucl Med 1993;34:1577-86.
    • (1993) J Nucl Med , vol.34 , pp. 1577-1586
    • Jaszczak, R.J.1    Gilland, D.R.2    Hanson, M.W.3    Jang, S.4    Greer, K.L.5    Coleman, R.E.6
  • 22
    • 0013939709 scopus 로고
    • Transmission scanning: A useful adjunct to conventional emission scanning for accurately keying isotope deposition to radiographic anatomy
    • Kuhl DE, Hale J, Eaton WL. Transmission scanning: a useful adjunct to conventional emission scanning for accurately keying isotope deposition to radiographic anatomy. Radiology 1966;87: 278-84.
    • (1966) Radiology , vol.87 , pp. 278-284
    • Kuhl, D.E.1    Hale, J.2    Eaton, W.L.3
  • 24
    • 0022411186 scopus 로고
    • A count-based algorithm for attenuation-corrected volume determination using data from an external flood source
    • Malko JA, Gullberg GT, Kowalsky WP, Van Heertum RL. A count-based algorithm for attenuation-corrected volume determination using data from an external flood source. J Nucl Med 1985;26:194-200.
    • (1985) J Nucl Med , vol.26 , pp. 194-200
    • Malko, J.A.1    Gullberg, G.T.2    Kowalsky, W.P.3    Van Heertum, R.L.4
  • 25
    • 0022719492 scopus 로고
    • SPECT liver imaging using an iterative attenuation correction algorithm and an external flood source
    • Malko JA, Van Heertum RL, Gullberg GT, Kowalsky WP. SPECT liver imaging using an iterative attenuation correction algorithm and an external flood source. J Nucl Med 1986;27:701-5.
    • (1986) J Nucl Med , vol.27 , pp. 701-705
    • Malko, J.A.1    Van Heertum, R.L.2    Gullberg, G.T.3    Kowalsky, W.P.4
  • 26
    • 0025416919 scopus 로고
    • Attenuation maps for SPECT determined using cone beam transmission computed tomography
    • Manglos SH, Bassano DA, Duxbury CE, Capone RB. Attenuation maps for SPECT determined using cone beam transmission computed tomography. IEEE Trans Nucl Sci 1990;37:600-8.
    • (1990) IEEE Trans Nucl Sci , vol.37 , pp. 600-608
    • Manglos, S.H.1    Bassano, D.A.2    Duxbury, C.E.3    Capone, R.B.4
  • 27
    • 0025893113 scopus 로고
    • Cone-beam transmission computed tomography for nonuniform attenuation compensation of SPECT images
    • Manglos SH, Bassano DA, Thomas FD. Cone-beam transmission computed tomography for nonuniform attenuation compensation of SPECT images. J Nucl Med 1991;32:1813-20.
    • (1991) J Nucl Med , vol.32 , pp. 1813-1820
    • Manglos, S.H.1    Bassano, D.A.2    Thomas, F.D.3
  • 28
    • 0027211983 scopus 로고
    • Phantom study of breast tissue attenuation in myocardial imaging
    • Manglos SH, Thomas FD, Gagne GM, Hellwig BJ. Phantom study of breast tissue attenuation in myocardial imaging. J Nucl Med 1993;34:992-6.
    • (1993) J Nucl Med , vol.34 , pp. 992-996
    • Manglos, S.H.1    Thomas, F.D.2    Gagne, G.M.3    Hellwig, B.J.4
  • 29
    • 0027429814 scopus 로고
    • A scanning line source for simultaneous emission and transmission measurements in SPECT
    • Tan P, Bailey DL, Meikle SR, Eberl S, Fulton RR, Hutton BF. A scanning line source for simultaneous emission and transmission measurements in SPECT. J Nucl Med 1993;30:1752-60.
    • (1993) J Nucl Med , vol.30 , pp. 1752-1760
    • Tan, P.1    Bailey, D.L.2    Meikle, S.R.3    Eberl, S.4    Fulton, R.R.5    Hutton, B.F.6
  • 31
    • 0029564459 scopus 로고
    • Attenuation compensation for cardiac single-photon emission computed tomographic imaging, part 1: Impact of attenuation and methods of estimating attenuation map
    • King MA, Tsui BMW, Tan TS. Attenuation compensation for cardiac single-photon emission computed tomographic imaging, part 1: impact of attenuation and methods of estimating attenuation map. J Nucl Cardiol 1995;12:513-24.
    • (1995) J Nucl Cardiol , vol.12 , pp. 513-524
    • King, M.A.1    Tsui, B.M.W.2    Tan, T.S.3
  • 34
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1982;MI1:113-22.
    • (1982) IEEE Trans Med Imaging , vol.MI1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 35
    • 0025068780 scopus 로고
    • Quantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of ischemic heart disease
    • Mahmarian JJ, Boyce TM, Goldberg RK, Cocanougher MK, Roberts R, Verani MS. Quantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of ischemic heart disease. J Am Coll Cardiol 1990;15:318-29.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 318-329
    • Mahmarian, J.J.1    Boyce, T.M.2    Goldberg, R.K.3    Cocanougher, M.K.4    Roberts, R.5    Verani, M.S.6
  • 37
    • 0027339963 scopus 로고
    • 201Tl single-photon emission computed tomography for the early assessment of patients surviving acute myocardial infarction
    • 201Tl single-photon emission computed tomography for the early assessment of patients surviving acute myocardial infarction. Circulation 1993;87:1197-210.
    • (1993) Circulation , vol.87 , pp. 1197-1210
    • Mahmarian, J.J.1    Pratt, C.M.2    Nishimura, S.3    Abreu, A.4    Verani, M.S.5
  • 39
    • 9044240323 scopus 로고
    • Evaluation of the effect of truncation in fan-beam cardiac SPECT using an observer study
    • Gregoriou GK, Tsui BMW, Gullberg GT. Evaluation of the effect of truncation in fan-beam cardiac SPECT using an observer study [abstract]. J Nucl Med 1994;35:4p-5p.
    • (1994) J Nucl Med , vol.35
    • Gregoriou, G.K.1    Tsui, B.M.W.2    Gullberg, G.T.3
  • 40
    • 0029040704 scopus 로고
    • Truncation artifact reduction in transmission CT for improved SPECT attenuation compensation
    • Kadrmas DJ, Jaszczak RJ, McCormick JW, Coleman RE, Lim CB. Truncation artifact reduction in transmission CT for improved SPECT attenuation compensation. Phys Med Biol 1995;40:1085-104.
    • (1995) Phys Med Biol , vol.40 , pp. 1085-1104
    • Kadrmas, D.J.1    Jaszczak, R.J.2    McCormick, J.W.3    Coleman, R.E.4    Lim, C.B.5
  • 41
    • 0028807603 scopus 로고
    • Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies
    • O'Connor MK, Caiati C, Christian TF, Gibbons RJ. Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies. J Nucl Med 1995;36:2080-6.
    • (1995) J Nucl Med , vol.36 , pp. 2080-2086
    • O'Connor, M.K.1    Caiati, C.2    Christian, T.F.3    Gibbons, R.J.4
  • 42
    • 0028818273 scopus 로고
    • A transmission map-based scatter correction technique for SPECT in inhomogenous media
    • Welch A, Gulberg GT, Christian PE, Datz FL. A transmission map-based scatter correction technique for SPECT in inhomogenous media. Med Phys 1995;22:1627-35.
    • (1995) Med Phys , vol.22 , pp. 1627-1635
    • Welch, A.1    Gulberg, G.T.2    Christian, P.E.3    Datz, F.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.