메뉴 건너뛰기




Volumn 24, Issue 6, 1997, Pages 642-650

Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET-MRI study

Author keywords

Brain positron emission tomography magnetic resonance imaging study; Image registration; Visual detection

Indexed keywords

FLUORODEOXYGLUCOSE F 18;

EID: 0030748037     PISSN: 03406997     EISSN: None     Source Type: Journal    
DOI: 10.1007/s002590050099     Document Type: Article
Times cited : (46)

References (10)
  • 1
    • 0020761029 scopus 로고
    • Adjustable computerized brain atlas for transmission and emission tomography
    • Bohm C, Greitz T, Kingsley D, Gerggren BM, Olsson L. Adjustable computerized brain atlas for transmission and emission tomography. AJNR 1983; 4: 731-733.
    • (1983) AJNR , vol.4 , pp. 731-733
    • Bohm, C.1    Greitz, T.2    Kingsley, D.3    Gerggren, B.M.4    Olsson, L.5
  • 3
    • 0028526688 scopus 로고
    • Correlative image registration
    • Weber DA, Ivanovic M. Correlative image registration. Semin Nucl Med 1994; 24: 311-323.
    • (1994) Semin Nucl Med , vol.24 , pp. 311-323
    • Weber, D.A.1    Ivanovic, M.2
  • 6
    • 0030316187 scopus 로고    scopus 로고
    • Comparison and evaluation of retrospective intermodality image registration techniques
    • West J, Fitzpatrick JM, Wang MY, et al. Comparison and evaluation of retrospective intermodality image registration techniques. SPIE 1996; 2710: 332-347.
    • (1996) SPIE , vol.2710 , pp. 332-347
    • West, J.1    Fitzpatrick, J.M.2    Wang, M.Y.3
  • 8
    • 0027291649 scopus 로고
    • Accuracy of registration of PET, SPECT and MR images of a brain phantom
    • Turkington RG, Jaszczak RJ, Pelizzari CA, et al. Accuracy of registration of PET, SPECT and MR images of a brain phantom. J Nucl Med 1993; 34: 1587-1594.
    • (1993) J Nucl Med , vol.34 , pp. 1587-1594
    • Turkington, R.G.1    Jaszczak, R.J.2    Pelizzari, C.A.3
  • 9
    • 0031028413 scopus 로고    scopus 로고
    • Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures
    • Studholme C, Hill DLG, Hawkes DJ. Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. Med Phys 1997; 24: 25-36.
    • (1997) Med Phys , vol.24 , pp. 25-36
    • Studholme, C.1    Hill, D.L.G.2    Hawkes, D.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.