메뉴 건너뛰기




Volumn 38, Issue 10, 1997, Pages 1600-1603

Improved wrist fracture localization with digital overlay of bone scintigrams and radiographs

Author keywords

Bone scintigraphy; Multimodality; Wrist

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BONE RADIOGRAPHY; BONE SCINTISCANNING; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; MALE; PRIORITY JOURNAL; SCAPHOID BONE; WRIST FRACTURE;

EID: 0030744923     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (9)
  • 2
    • 0028082109 scopus 로고
    • Experience of the early use of technetium-99 bone scintigraphy in wrist injury
    • Shewring DJ, Savage R, Thomas G. Experience of the early use of technetium-99 bone scintigraphy in wrist injury. J Hand Surg [Br] 1994;198:114-117.
    • (1994) J Hand Surg [Br] , vol.198 , pp. 114-117
    • Shewring, D.J.1    Savage, R.2    Thomas, G.3
  • 3
    • 0028598809 scopus 로고
    • Scintigraphy in the evaluation of the "clinical" scaphoid fracture
    • Waizenegger M, Wastie ML, Barton NJ, Davis RC. Scintigraphy in the evaluation of the "clinical" scaphoid fracture. Hand Surg [Br] 1994:19B:6: 750-753.
    • (1994) Hand Surg [Br] , vol.19 B , Issue.6 , pp. 750-753
    • Waizenegger, M.1    Wastie, M.L.2    Barton, N.J.3    Davis, R.C.4
  • 5
    • 0025184288 scopus 로고
    • The principal axes information-a method for image registration
    • Alpert NM, Bradshaw JF, Kennedy D, Correia JA. The principal axes information-a method for image registration. J Nucl Med 1990;31:1717-1722.
    • (1990) J Nucl Med , vol.31 , pp. 1717-1722
    • Alpert, N.M.1    Bradshaw, J.F.2    Kennedy, D.3    Correia, J.A.4
  • 7
    • 0029009640 scopus 로고
    • Automated alignment and sizing of myocardial stress and rest scans to three-dimensional normal templates using an image registration alogrithm
    • Slomka PJ. Hurwitz GA, Stephenson J. Cradduck T. Automated alignment and sizing of myocardial stress and rest scans to three-dimensional normal templates using an image registration alogrithm.J Nucl Med 1995:36:115-122.
    • (1995) J Nucl Med , vol.36 , pp. 115-122
    • Slomka, P.J.1    Hurwitz, G.A.2    Stephenson, J.3    Cradduck, T.4
  • 8
    • 0025304887 scopus 로고
    • The orthopan tomoscintigram-a new application of emission computed tomography for facial bone scanning
    • Henze E. Graf G. Clausen M, et al. The orthopan tomoscintigram-a new application of emission computed tomography for facial bone scanning. Eur J Nucl Med 1990:16:97-101.
    • (1990) Eur J Nucl Med , vol.16 , pp. 97-101
    • Henze, E.1    Graf, G.2    Clausen, M.3
  • 9
    • 0006410788 scopus 로고
    • A volume-based image registration toolkit for automated comparison of paired nuclear medicine images
    • Slomka PJ. Hurwitz GA, Stepehenson JA. et al. A volume-based image registration toolkit for automated comparison of paired nuclear medicine images [Abstract]. Med Phys 1995:22:1017.
    • (1995) Med Phys , vol.22 , pp. 1017
    • Slomka, P.J.1    Hurwitz, G.A.2    Stepehenson, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.