Volumn 26, Issue 4, 1997, Pages 865-871

Engineering analysis of the effect of atrial contraction on mitral prosthetic valve closing

Author keywords

Atrial contraction; Closing motion; High speed video camera; Mechanical circulatory model; Mitral prosthetic valve

Indexed keywords

ARTICLE; BIOMECHANICS; BLOOD FLOW VELOCITY; CORONARY ARTERY BLOOD FLOW; EXPERIMENTAL MODEL; HEART ATRIUM CONTRACTILITY; MITRAL VALVE PROSTHESIS; TELEVISION CAMERA;

EID: 0030741328     PISSN: 03000818     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (23)
  • 1
    • 1842377110 scopus 로고    scopus 로고
    • Japanese source
  • 2
    • 1842412686 scopus 로고    scopus 로고
    • Japanese source
  • 3
    • 1842406218 scopus 로고    scopus 로고
    • Japanese source
  • 4
    • 1842365107 scopus 로고    scopus 로고
    • Japanese source
  • 5
    • 0022592273 scopus 로고
    • In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses
    • Woo YR, Yoganathan AP: In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses. J Biomech 19: 39, 1986
    • (1986) J Biomech , vol.19 , pp. 39
    • Woo, Y.R.1    Yoganathan, A.P.2
  • 6
    • 1842287591 scopus 로고    scopus 로고
    • Japanese source
  • 7
    • 1842337662 scopus 로고    scopus 로고
    • Japanese source
  • 9
    • 1842328205 scopus 로고    scopus 로고
    • Japanese source
  • 10
    • 1842368698 scopus 로고    scopus 로고
    • Japanese source
  • 11
    • 1842300051 scopus 로고    scopus 로고
    • Japanese source
  • 12
    • 1842300686 scopus 로고    scopus 로고
    • Japanese source
  • 13
    • 1842294779 scopus 로고
    • Effects of atrial contraction on mitral valve behavior in a new mock circulatory system
    • Naemura K, Umezu M, Kato Y, Nagao Y, Ranawake M, Fujimoto T: Effects of atrial contraction on mitral valve behavior in a new mock circulatory system. Artif Organs 17: 534, 1993
    • (1993) Artif Organs , vol.17 , pp. 534
    • Naemura, K.1    Umezu, M.2    Kato, Y.3    Nagao, Y.4    Ranawake, M.5    Fujimoto, T.6
  • 14
    • 1842414454 scopus 로고    scopus 로고
    • Japanese source
  • 15
    • 1842296570 scopus 로고    scopus 로고
    • Japanese source
  • 16
    • 1842412685 scopus 로고    scopus 로고
    • Japanese source
  • 20
    • 0020664067 scopus 로고
    • Prosthetic mitral valve motion during cardiac dysrhythmias as determined by echocardiography
    • Panidis IP, Morganroth J, David D, Chen CC, Kotler MN: Prosthetic mitral valve motion during cardiac dysrhythmias as determined by echocardiography. Am J Cardiol 51: 996, 1983
    • (1983) Am J Cardiol , vol.51 , pp. 996
    • Panidis, I.P.1    Morganroth, J.2    David, D.3    Chen, C.C.4    Kotler, M.N.5
  • 21
    • 0028533242 scopus 로고
    • Transient behavior analysis of a mechanical monoleaflet heart valve prosthesis in the closing phase
    • Cheon GJ, Chandran KB: Transient behavior analysis of a mechanical monoleaflet heart valve prosthesis in the closing phase. Trans ASME J Biomech Eng 116: 452, 1994
    • (1994) Trans ASME J Biomech Eng , vol.116 , pp. 452
    • Cheon, G.J.1    Chandran, K.B.2
  • 22
    • 85047680876 scopus 로고
    • Fluid mechanics of a model mitral valve and left ventricle
    • Bellhouse BJ: Fluid mechanics of a model mitral valve and left ventricle. Cardiovasc Res 6: 199, 1972
    • (1972) Cardiovasc Res , vol.6 , pp. 199
    • Bellhouse, B.J.1
  • 23
    • 0019425554 scopus 로고
    • Fluid mechanics of the natural mitral valve
    • Reul H, Talukder N, Muller EW: Fluid mechanics of the natural mitral valve. J Biomech 14: 361, 1981
    • (1981) J Biomech , vol.14 , pp. 361
    • Reul, H.1    Talukder, N.2    Muller, E.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.