1
-
-
8244251184
-
Theoretical calculations of the optimum current distribution for an elliptical birdcage RF coil
-
C. S. Li, M. B. Smith, Theoretical calculations of the optimum current distribution for an elliptical birdcage RF coil, in "Proc., SMRM, 12th Annual Meeting, New York, 1993," p. 1342.
-
Proc., SMRM, 12th Annual Meeting, New York, 1993
, pp. 1342
-
-
Li, C.S.1
Smith, M.B.2
-
2
-
-
0002488039
-
An elliptical cross section birdcage body coil
-
W. E. Bimson, P. A. Martin, R. D. Griffiths, R. H. T. Edwards, An elliptical cross section birdcage body coil, in "Proc., SMRM, 11th Annual Meeting, Berlin, 1992," p. 272.
-
Proc., SMRM, 11th Annual Meeting, Berlin, 1992
, pp. 272
-
-
Bimson, W.E.1
Martin, P.A.2
Griffiths, R.D.3
Edwards, R.H.T.4
-
3
-
-
0002432034
-
Design of elliptically shaped quadrature pediatric body coils
-
R. Kurczewski, R. Pavlovich, J. W. Steidly, N. K. Rollins, Design of elliptically shaped quadrature pediatric body coils, in "Proc., SMRM, 11th Annual Meeting, Berlin, 1992," p. 4025.
-
Proc., SMRM, 11th Annual Meeting, Berlin, 1992
, pp. 4025
-
-
Kurczewski, R.1
Pavlovich, R.2
Steidly, J.W.3
Rollins, N.K.4
-
4
-
-
84914782446
-
Three wrist coil designs with high signal-to-noise performance
-
C. Hayes, C. Mathis, Three wrist coil designs with high signal-to-noise performance, in "Proc., SMRM, 12th Annual Meeting, New York, 1993," p. 309.
-
Proc., SMRM, 12th Annual Meeting, New York, 1993
, pp. 309
-
-
Hayes, C.1
Mathis, C.2
-
5
-
-
0002142309
-
Optimization of RF coil design using genetic algorithm and simulated annealing method
-
N. Lu, J. Jin, E. Michielssen, R. Magin, Optimization of RF coil design using genetic algorithm and simulated annealing method, in "Proc., SMR, 3rd Annual Meeting, Nice, France, 1995," p. 1002.
-
Proc., SMR, 3rd Annual Meeting, Nice, France, 1995
, pp. 1002
-
-
Lu, N.1
Jin, J.2
Michielssen, E.3
Magin, R.4
-
7
-
-
0030244610
-
An analysis and optimization of elliptical RF probes used in magnetic resonance imaging
-
L. K. Forbes, S. Crozier, D. M. Doddrell, An analysis and optimization of elliptical RF probes used in magnetic resonance imaging. Meas. Sci. Technol. 7, 1281-1290 (1996).
-
(1996)
Meas. Sci. Technol.
, vol.7
, pp. 1281-1290
-
-
Forbes, L.K.1
Crozier, S.2
Doddrell, D.M.3
-
8
-
-
0003952728
-
-
McGraw-Hill, New York
-
P. M. Morse, H. Feshbach, "Methods of Theoretical Physics," vol. 2, McGraw-Hill, New York, 1953.
-
(1953)
Methods of Theoretical Physics
, vol.2
-
-
Morse, P.M.1
Feshbach, H.2
-
10
-
-
9844270043
-
Elliptic and circular current sheets to produce a prescribed internal field
-
R. A. Beth, Elliptic and circular current sheets to produce a prescribed internal field. IEEE Trans. Nucl. Sci. 14, 386-388 (1967).
-
(1967)
IEEE Trans. Nucl. Sci.
, vol.14
, pp. 386-388
-
-
Beth, R.A.1
-
11
-
-
0000597869
-
Quadrature detection coils - A further √2 improvement in sensitivity
-
C. N. Chen, D. I. Hoult, V. J. Sank, Quadrature detection coils - a further √2 improvement in sensitivity. J. Magn. Reson. 54, 324-327 (1983).
-
(1983)
J. Magn. Reson.
, vol.54
, pp. 324-327
-
-
Chen, C.N.1
Hoult, D.I.2
Sank, V.J.3
-
14
-
-
46549092488
-
An efficient, highly homogeneous radiofrequency coil for wholebody NMR imaging at 1.5 T
-
C. E. Hayes, W. A. Edelstein, J. F. Schenck, O. M. Mueller, M. Eash, An efficient, highly homogeneous radiofrequency coil for wholebody NMR imaging at 1.5 T. J. Magn. Reson. 63, 622-628 (1985).
-
(1985)
J. Magn. Reson.
, vol.63
, pp. 622-628
-
-
Hayes, C.E.1
Edelstein, W.A.2
Schenck, J.F.3
Mueller, O.M.4
Eash, M.5
-
15
-
-
9844227287
-
-
Brookhaven National Laboratory, Accelerator Department Report AADD-112
-
R. A. Beth, Fields produced by elliptical current sheets. Brookhaven National Laboratory, Accelerator Department Report AADD-112 (1966).
-
(1966)
Fields Produced by Elliptical Current Sheets
-
-
Beth, R.A.1
-
16
-
-
9844229006
-
-
Mathsoft, Inc., Cambridge, MA
-
Mathcad®, ver. 6.0 Plus. Mathsoft, Inc., Cambridge, MA.
-
Mathcad®, Ver. 6.0 Plus
-
-
-
17
-
-
0024733303
-
A technique for double resonant operation of birdcage imaging coils
-
P. M. Joseph, D. Lu, A technique for double resonant operation of birdcage imaging coils. IEEE Trans. Med. Imaging 8,3, 286-294 (1989).
-
(1989)
IEEE Trans. Med. Imaging
, vol.8
, Issue.3
, pp. 286-294
-
-
Joseph, P.M.1
Lu, D.2
-
18
-
-
0002100145
-
Resonant modes of the birdcage coil
-
M. C. Leifer, Resonant modes of the birdcage coil. J. Magn. Reson. 124, 51-60 (1997).
-
(1997)
J. Magn. Reson.
, vol.124
, pp. 51-60
-
-
Leifer, M.C.1
-
19
-
-
0026750735
-
Explicit treatment of mutual inductance in eight-column birdcage resonators
-
R. Pascone, T. Vullo, J. Farrelly, P. Cahill, Explicit treatment of mutual inductance in eight-column birdcage resonators. J. Magn. Reson. Imaging 10, 401-410 (1992).
-
(1992)
J. Magn. Reson. Imaging
, vol.10
, pp. 401-410
-
-
Pascone, R.1
Vullo, T.2
Farrelly, J.3
Cahill, P.4
-
20
-
-
9844236950
-
Mutual inductance in the birdcage resonator
-
J. Tropp, Mutual inductance in the birdcage resonator, in "Proc., SMRM, 12th Annual Meeting, New York, 1993," p. 1347.
-
Proc., SMRM, 12th Annual Meeting, New York, 1993
, pp. 1347
-
-
Tropp, J.1
-
21
-
-
0009567930
-
The theory of an arbitrarily perturbed birdcage resonator and a simple method for restoring it to full symmetry
-
J. Tropp, The theory of an arbitrarily perturbed birdcage resonator and a simple method for restoring it to full symmetry. J. Magn. Reson. 95, 235-243 (1991).
-
(1991)
J. Magn. Reson.
, vol.95
, pp. 235-243
-
-
Tropp, J.1
-
22
-
-
9844254425
-
Mutual inductance in the low-pass birdcage resonator
-
J. Tropp, Mutual inductance in the low-pass birdcage resonator, in "Proc., SMRM, 11th Annual Meeting, Berlin, 1992," p. 273.
-
Proc., SMRM, 11th Annual Meeting, Berlin, 1992
, pp. 273
-
-
Tropp, J.1
|