메뉴 건너뛰기




Volumn 20, Issue 11, 1997, Pages 2775-2782

The combined transvenous implantation of cardioverter defibrillators and permanent pacemakers

Author keywords

ICD; Pacemaker; Transvenous leads

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; BRADYCARDIA; CARDIOVERSION; CLINICAL ARTICLE; DEFIBRILLATION; FEMALE; FOLLOW UP; HEART PACING; HEART VENTRICLE ARRHYTHMIA; HUMAN; IMPLANTATION; MALE; R WAVE; TACHYCARDIA;

EID: 0030713468     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1997.tb05435.x     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 33847459356 scopus 로고
    • Jewel PCD Model 7219, Technical Manual
    • Medtronic, Inc. Jewel PCD Model 7219, Technical Manual. Minneapolis, Medtronic, Inc., 1994, pp. 3-1.
    • (1994) Minneapolis, Medtronic, Inc. , pp. 3-11
  • 2
    • 0026032234 scopus 로고
    • Device interaction-antitachycardia pacemakers and defibrillators for sustained ventricular tachycardia
    • Ahem TS, Nydegger C, McCormick DJ, et al. Device interaction-antitachycardia pacemakers and defibrillators for sustained ventricular tachycardia. PACE 1991; 14:302-307.
    • (1991) PACE , vol.14 , pp. 302-307
    • Ahem, T.S.1    Nydegger, C.2    McCormick, D.J.3
  • 3
    • 0024990874 scopus 로고
    • Clinical interactions between pacemakers and automatic implantable cardioverter-defibrillators
    • Calkins H, Brinker J, Veltri EP, et al. Clinical interactions between pacemakers and automatic implantable cardioverter-defibrillators. J Am Coll Cardiol 1990; 16:666-673.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 666-673
    • Calkins, H.1    Brinker, J.2    Veltri, E.P.3
  • 4
    • 0024270487 scopus 로고
    • The use and interaction of permanent pacemakers and the automatic implantable cardioverter defibrillator
    • Cohen AI, Wish MH, Fletcher RD, et al. The use and interaction of permanent pacemakers and the automatic implantable cardioverter defibrillator. PACE 1988; 11:704-711.
    • (1988) PACE , vol.11 , pp. 704-711
    • Cohen, A.I.1    Wish, M.H.2    Fletcher, R.D.3
  • 5
    • 0024576280 scopus 로고
    • Combined automatic implantable cardioverter-defibrillator and pacemaker systems: Implantation techniques and follow-up
    • Epstein AE, Kay GN, Plumb VJ, et al. Combined automatic implantable cardioverter-defibrillator and pacemaker systems: Implantation techniques and follow-up. J Am Coll Cardiol 1989; 13:121-131.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 121-131
    • Epstein, A.E.1    Kay, G.N.2    Plumb, V.J.3
  • 6
    • 0028817526 scopus 로고
    • Implantation of transvenous nonthoracotomy cardioverterdefibrillator systems in patients with endocardial pacemakers
    • Brooks R, Garan H, McGovern BA, et al. Implantation of transvenous nonthoracotomy cardioverterdefibrillator systems in patients with endocardial pacemakers. Am Heart J 1995; 129:45-53.
    • (1995) Am Heart J , vol.129 , pp. 45-53
    • Brooks, R.1    Garan, H.2    McGovern, B.A.3
  • 7
    • 0022499298 scopus 로고
    • Unipolar pacer artifacts induced failure of an automatic implantable cardioverter/defibrillator to detect ventricular fibrillation
    • Kim SG, Furman S, Waspe LE, et al. Unipolar pacer artifacts induced failure of an automatic implantable cardioverter/defibrillator to detect ventricular fibrillation. Am J Cardiol 1986; 57: 880-881.
    • (1986) Am J Cardiol , vol.57 , pp. 880-881
    • Kim, S.G.1    Furman, S.2    Waspe, L.E.3
  • 8
    • 0026638421 scopus 로고
    • Pacemaker syndrome: An iatrogenic condition
    • Travill CM, Sutton R. Pacemaker syndrome: An iatrogenic condition. Br Heart J 1992; 68:163-166.
    • (1992) Br Heart J , vol.68 , pp. 163-166
    • Travill, C.M.1    Sutton, R.2
  • 10
    • 0030022114 scopus 로고    scopus 로고
    • Combined third-generation implantable cardioverter defibrillator with permanent unipolar pacemakers: Preliminary observations
    • Haffajee C, Casavant D, Desai P, et al. Combined third-generation implantable cardioverter defibrillator with permanent unipolar pacemakers: Preliminary observations. PACE 1996; 19:136-142.
    • (1996) PACE , vol.19 , pp. 136-142
    • Haffajee, C.1    Casavant, D.2    Desai, P.3
  • 11
    • 0028878208 scopus 로고
    • Effect of implantable nonthoracotomy defibrillation system on permanent pacemakers: An in vitro analysis with clinical implications
    • van Lake PJ, Levine PA, Mouchawar GA. Effect of implantable nonthoracotomy defibrillation system on permanent pacemakers: An in vitro analysis with clinical implications. PACE 1995; 18: 182-187.
    • (1995) PACE , vol.18 , pp. 182-187
    • Lake, P.J.1    Levine, P.A.2    Mouchawar, G.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.