메뉴 건너뛰기




Volumn 11, Issue 5, 1997, Pages 622-628

A fully automated comparative microaneurysm digital detection system

Author keywords

Computer; Diabetes; Digitisation; Microaneurysm; Retinopathy

Indexed keywords

ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; COMPUTER ASSISTED DIAGNOSIS; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DATA BASE; DIABETES MELLITUS; DIABETIC RETINOPATHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FLUORESCENCE ANGIOGRAPHY; HUMAN; IMAGE PROCESSING; INFORMATION PROCESSING; INTERMETHOD COMPARISON; MICROANEURYSM; REPRODUCIBILITY; RETINA FOVEA; RETINA IMAGE; STATISTICS;

EID: 0030711537     PISSN: 0950222X     EISSN: None     Source Type: Journal    
DOI: 10.1038/eye.1997.166     Document Type: Article
Times cited : (155)

References (9)
  • 1
    • 0022481966 scopus 로고
    • Does microaneurysm count reflect severity of early diabetic retinopathy?
    • Kohner EM, Sleightholm M, and KROC Collaborative Study Group. Does microaneurysm count reflect severity of early diabetic retinopathy? Ophthalmology 1986;93:586-9.
    • (1986) Ophthalmology , vol.93 , pp. 586-589
    • Kohner, E.M.1    Sleightholm, M.2
  • 2
    • 0024793671 scopus 로고
    • The relationship of retinal microaneurysm counts to the 4-year progression of diabetic retinopathy
    • Klein R, Meuer SM, Moss SE, Klein BEK. The relationship of retinal microaneurysm counts to the 4-year progression of diabetic retinopathy. Arch Ophthalmol 1989;107:1780-5.
    • (1989) Arch Ophthalmol , vol.107 , pp. 1780-1785
    • Klein, R.1    Meuer, S.M.2    Moss, S.E.3    Klein, B.E.K.4
  • 3
    • 0020905201 scopus 로고
    • Automatic detection of microaneurysms in retinopathy fluoro-angiogram
    • Lay B, Baudoin C, Klein JC. Automatic detection of microaneurysms in retinopathy fluoro-angiogram. Proc SPIE 1983;432:165-73.
    • (1983) Proc SPIE , vol.432 , pp. 165-173
    • Lay, B.1    Baudoin, C.2    Klein, J.C.3
  • 5
    • 0042262446 scopus 로고    scopus 로고
    • An image-processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus
    • Spencer T, Olson JA, McHardy KC, Sharp PF, Forrester JV. An image-processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus. Comp Biomed Res 1996;29:284-302.
    • (1996) Comp Biomed Res , vol.29 , pp. 284-302
    • Spencer, T.1    Olson, J.A.2    McHardy, K.C.3    Sharp, P.F.4    Forrester, J.V.5
  • 8
    • 0022470978 scopus 로고
    • ROC methodology in radiologie imaging
    • Metz CE. ROC methodology in radiologie imaging. Invest Radiol 1986;21:720-33.
    • (1986) Invest Radiol , vol.21 , pp. 720-733
    • Metz, C.E.1
  • 9
    • 0014879416 scopus 로고
    • The rate of formation and disappearance of microaneurysms in diabetic retinopathy
    • Kohner EM, Dollery CT. The rate of formation and disappearance of microaneurysms in diabetic retinopathy. Eur J Clin Invest 1970;1:167-71.
    • (1970) Eur J Clin Invest , vol.1 , pp. 167-171
    • Kohner, E.M.1    Dollery, C.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.